Mostrar el registro sencillo del ítem

dc.contributor.advisorGonzález Cadenillas, , Clayder
dc.contributor.authorLizarzaburu Bazán, Piero
dc.contributor.authorVillanueva Samoluk, Javier
dc.creatorLizarzaburu Bazán, Piero
dc.date.accessioned2023-01-19T16:33:37Z
dc.date.available2023-01-19T16:33:37Z
dc.date.issued2023
dc.identifier.urihttps://hdl.handle.net/20.500.12759/10140
dc.description.abstractEn la presente investigación se hizo un estudio de diversos filtros digitales que puedan cumplir con la tarea de filtrar, en tiempo real, y usando una tarjeta de adquisición de datos (TAD), señales PPG obtenidas para calcular la hemoglobina en la sangre de una persona. Es por esto que, la tarea de filtrar estas señales fotopletismográficas (PPG), es crucial, ya que un mal filtrado puede terminar en un mal cálculo de hemoglobina. El primer paso fue estudiar el estado del arte alrededor del filtrado de señales PPG y así determinar cuáles pueden ser las opciones para hacer el filtrado. Posteriormente, se obtuvieron señales PPG sin filtrar de pacientes para su estudio, lo que permitió determinar los parámetros para los filtros elegidos. Luego de ello se determinaron las ecuaciones y los algoritmos para poder hacer la comparación necesaria para la determinación del filtro. Una vez determinadas las ecuaciones y algoritmos, se procedió a hacer su implementación en PyCharm, usando el lenguaje de programación Python, lo que permitió determinar los indicadores para la comparación de los filtros y la determinación del más eficiente, es decir, que optimice los recursos computacionales disponibles sin consumo excesivo. Una vez realizada la comparación, se determinó, según las necesidades del proyecto, cuál es el filtro que cumplía los requerimientos, lo que resultó en el filtro Butterworth de orden 6. Con la determinación del filtro, se procedió a desarrollarlo en lenguaje C para luego implementarse en el microcontrolador del proyecto, validando que el filtro, funciona según los requerimientos previamente establecidos.es_PE
dc.description.abstractIn the present investigation a study of many digital filters was made that may accomplish the task of filtering, in real time, and using a data acquisition board (DAQ), PPG signals obtained to calculate hemoglobin in a person’s blood. This is why, the task of filtering these PPG signals, is crucial, because, a bad filtering, may result in a bad hemoglobin calculation. The first step was studying the state of art surrounding photoplethysmographic signal (PPG) filtering, that way, determining which options may do the filtering task. After that, unfiltered PPG signals were obtained from patients, for its study, that way, the parameters needed, could be determined for the study of the chosen filters. After that, the equations and algorithms needed were determined for making the comparison for the filter determination. Once the equations and algorithms needed were determined, the implementation in PyCharm was done, using Python programming language, which allowed us to determine the indicators for the filter’s comparison and the determination of the most efficient one, that it optimizes the available computational resources without excessive consumption. When the comparative table was done, it was determined that, following the project needs, the most adequate filter, turned to be order 6 Butterworth filter. With this result, it was developed the filter in C language so it could be implemented in the microprocessor of the project, validating that this filter, works according to the previously established requirements.en_US
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada Antenor Orrego - UPAOes_PE
dc.relation.ispartofseriesT_ELECT_879
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/es_PE
dc.sourceUniversidad Privada Antenor Orregoes_PE
dc.sourceRepositorio institucional - UPAOes_PE
dc.subjectFiltroses_PE
dc.subjectSeñaleses_PE
dc.titleDesarrollo de un filtro digital para señales foto pletismográficas obtenidas de una tarjeta de adquisición de datos en un entorno de laboratorioes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.grantorUniversidad Privada Antenor Orrego. Facultad de Ingenieríaes_PE
thesis.degree.nameIngeniero Electronicoes_PE
thesis.degree.disciplineIngeniería Electrónicaes_PE
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#2.11.00es_PE
renati.advisor.orcidhttps://orcid.org/0000-0002-6777-4479es_PE
renati.author.dni76344364
renati.author.dni74163148
renati.advisor.dni44565065
renati.typehttp://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttp://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.discipline712026es_PE
renati.jurorCerna Sánchez, Elmer
renati.jurorTrujillo Silva, Marco
renati.jurorRamos Rojas, Ovidio
dc.publisher.countryPEes_PE


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(es)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess