Show simple item record

dc.contributor.advisorVértiz Malabrigo, Manuel Alberto
dc.contributor.authorSanchez Marin, Rodrigo Alessandro
dc.creatorSanchez Marin, Rodrigo Alessandro
dc.date.accessioned2023-02-27T17:00:05Z
dc.date.available2023-02-27T17:00:05Z
dc.date.issued2023
dc.identifier.urihttps://hdl.handle.net/20.500.12759/10367
dc.description.abstractEn el presente proyecto de tesis se formuló el DISEÑO DEL SISTEMA DE ALCANTARILLADO SANITARIO Y CONEXIONES DOMICILIARIAS, EN LA LOCALIDAD PERIFERICA EL PLATANAR EN CASCAS, GRAN CHIMÚ – LA LIBERTAD, USANDO EL PROGRAMA SEWERCAD; para el abastecimiento de redes de alcantarillado sanitario a la población del sector platanar. Para el cálculo hidráulico de alcantarillado se diseñará considerando las normas de obras de saneamiento (OS. 070) necesario para cumplir con los criterios de diseño para un óptimo proyecto a desarrollar en la zona rural del platanar. Adjuntando en el padrón la cantidad de viviendas existentes para el cálculo poblacional, asimismo se realizó un estudio de mecánica de suelos para identificar que sales solubles se encuentran y puedan afectar a la red de alcantarillado, por otro lado, se realizó un levantamiento topográfico para la definición de la red de alcantarillado; todo esto es necesario para ser usado en el diseño y cálculo hidráulico del alcantarillado en el software SEWERCAD. La zona del platanar presenta cotas altas y bajas por ser zona rural, esto me obliga a tener en cuenta la altura de buzones, en ciertos tramos de tubería se tiene que incrementar la altura de buzón del mínimo que es 1.20 m; contando con cinco buzones de arranque (Bz-01, Bz-06, Bz-08, Bz-49, Bz-45A), 64 buzones distribuidos en toda la red de alcantarillado, con 64 tramos de tubería, teniendo así una longitud total de tubería de 2965.02 metros lineales; se deberá cumplir con los criterios establecidos en la OS. 070, para una óptima proyección del sistema de redes. Se tiene como objetivo la realización del diseño y cálculo hidráulico del sistema de alcantarillado para dotar con un sistema de red de alcantarillado y evacuar las aguas residuales de esta zona a una PTAR. Con esto llegamos a la conclusión de la importancia de proporcionar un tendido de tuberías a lo largo de la zona el platanar rigiéndonos de un cálculo hidráulico de alcantarilladoes_PE
dc.description.abstractIn this thesis project, the DESIGN OF THE SANITARY SEWERAGE SYSTEM AND DOMICILIARY CONNECTIONS IN THE PERIPHERAL LOCALITY OF EL PLATANAR IN CASCAS, GRAN CHIMÚ - LA LIBERTAD, USING THE SEWERCAD PROGRAM, was formulated for the supply of sanitary sewerage networks to the population of the platanar sector. For the hydraulic calculation of the sewerage system, it will be designed considering the sanitation works standards (OS. 070) necessary to comply with the design criteria for an optimal project to be developed in the rural area of El Platanar. Also, a soil mechanics study was carried out to identify the soluble salts that are found and may affect the sewerage network, on the other hand, a topographic survey was carried out to define the sewerage network; all this is necessary to be used in the design and hydraulic calculation of the sewerage system in the SEWERCAD software. The banana plantation area has high and low levels because it is a rural area, this forces me to take into account the height of mailboxes, in certain sections of pipes the height of the mailbox must be increased from the minimum, which is 1.20 m; having five starting mailboxes (Bz-01, Bz-06, Bz-08, Bz-49, Bz-45A), 64 mailboxes distributed throughout the sewerage network, with 64 pipe sections, thus having a total length of pipeline of 2965.02 linear meters; the criteria established in the OS must be met. 070, for an optimal projection of the net system. The objective is to carry out the design and hydraulic calculation of the sewage system to provide a sewage network system and evacuate wastewater from this area. With this we conclude the importance of providing a piping system along the Platanar area, based on a hydraulic sewerage calculationen_US
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada Antenor Orrego - UPAOes_PE
dc.relation.ispartofseriesT_CIVIL_2206
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/es_PE
dc.sourceUniversidad Privada Antenor Orregoes_PE
dc.sourceRepositorio institucional - UPAOes_PE
dc.subjectAlcantarilladoes_PE
dc.subjectSanitarioes_PE
dc.titleDiseño del sistema de alcantarillado sanitario y conexiones domiciliarias en la localidad periférica El Platanar Cascas, Gran Chimu - La Libertad, usando el programa Sewercades_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.grantorUniversidad Privada Antenor Orrego. Facultad de Ingenieríaes_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.disciplineIngeniería Civiles_PE
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#2.01.00es_PE
renati.advisor.orcidhttps://orcid.org/0000-0001-9168-8258es_PE
renati.author.dni72673089
renati.advisor.dni18112316
renati.typehttp://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttp://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.discipline732016es_PE
renati.jurorCabanillas Quiroz, Guillermo
renati.jurorVargas López, Alfredo
renati.jurorGálvez Paredes, José
dc.publisher.countryPEes_PE


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess