Show simple item record

dc.contributor.advisorSalazar Perales, Alvaro Fernando
dc.contributor.authorContreras Paredes, Nataly Vanessa
dc.creatorContreras Paredes, Nataly Vanessa
dc.date.accessioned2024-01-19T16:47:39Z
dc.date.available2024-01-19T16:47:39Z
dc.date.issued2024
dc.identifier.urihttps://hdl.handle.net/20.500.12759/18772
dc.description.abstractEn la presente investigación el estudio topográfico fue realizado con una precisión de 10 cm/píxel, bajo cielo despejado, el relieve identificado en el sitio es escarpado y se logró cubrir un área total de 52.84 hectáreas, facilitando así la ubicación y mapeo de la infraestructura en general y brindando facilidades para ubicar áreas con mejores condiciones para el establecimiento estructuras de tratamiento primario, la cantidad de habitantes se obtuvo a través de una implementación documental en la que se registraron los residentes con un total de 2900 habitantes y gracias a la estadística formulación se determinó la población futura que es un total de 3952,32 para un límite de 20 años, el caudal máximo horario obtenido por el estudio es de 11.769 l/s, pero teniendo en cuenta un retorno del 80%, lo que da 9.415 l/s/Hab, este caudal resultó insuficiente para efectos de diseñar y evaluar el desempeño de las redes de alcantarillado, por lo que se decidió que la red cumpla con los estándares mínimos establecidos por la norma, la cual indica que es necesario por lo menos un caudal de 1.5 l/s en cada tramo, basándose en lo citado se realizó el ajuste y corrección, la propuesta actual se hace en base al escurrimiento natural de las calles con el fin de obtener una solución sustentable que no sea costosa de implementar, y al mismo tiempo mismo tiempo no requiere cambios significativos en la topografía, pero se debe enfatizar que algunas calles probablemente requerirán un volumen pequeño para compensar las pendientes de la tubería instalada y la profundidad de los pozos de inspección, también se consideró la ubicación estratégica de los buzones de inspección con una profundidad no superior a 1,20 m, el software utilizado para el modelamiento es SEWERCAD, aunque presenta ciertas limitaciones de diseño requiere mucho criterio, por tal motivo, la consulta en todo momento ha sido constante con la normatividad peruana. Otro punto a destacar fue la iteración del software en relación a los diámetros de las tuberías utilizadas, en este último el software se consideró restrictivo , en el caso de diámetros comerciales, para facilitar la adquisición de cada una de las tuberías en el futuro hipotético, es necesario aclarar que el software es eficaz en los cálculos de rendimiento, los cuales se basan totalmente en criterios técnicos, para obtener finalmente un cálculo de red que este dimensionado satisfactoriamente.es_PE
dc.description.abstractIn the present investigation, the topographic study was carried out with a precision of 10 cm/pixel, under clear skies, the relief identified on the site is steep and a total area of 52.84 hectares was covered, thus facilitating the location and mapping of the infrastructure. in general and providing facilities to locate areas with better conditions for the establishment of primary treatment structures, the number of inhabitants was obtained through a documentary implementation in which residents with a total of 2900 inhabitants were registered and thanks to the statistical formulation the future population was determined, which is a total of 3952.32 for a limit of 20 years, the maximum hourly flow obtained by the study is 11,769 l/s, but taking into account a return of 80%, which gives 9,415 l /s/Hab, this flow was insufficient for purposes of designing and evaluating the performance of sewerage networks, so it was decided that the network complies with the standards is minimum established by the norm, which indicates that at least a flow of 1.5 l/s is necessary in each section, based on the above, the adjustment and correction was made, the current proposal is made based on the natural runoff of the streets in order to obtain a sustainable solution that is not expensive to implement, and at the same time does not require significant changes in topography, but it must be emphasized that some streets will probably require a small volume to compensate for the slopes of the installed pipe and the depth of the inspection wells, the strategic location of the inspection pits with a depth not exceeding 1.20 m was also considered, the software used for modeling is SEWERCAD, although it has certain design limitations, it requires a lot of criteria, For this reason, the consultation at all times has been consistent with Peruvian regulations. Another point to highlight was the iteration of the software in relation to the diameters of the pipes used, in the latter the software was considered restrictive or, in the case of commercial diameters, to facilitate the acquisition of each of the pipes in the hypothetical future. , it is necessary to clarify that the software is effective in performance calculations, but ineffective in automating the process, since, as in S, they are recently totally based on technical criteria or, in this case, the researcher, finally the network is successfully sizedes_PE
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada Antenor Orregoes_PE
dc.relation.ispartofseriesT_CIVIL_2451
dc.rightsinfo:eu-repo/semantics/closedAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/es_PE
dc.subjectTanquees_PE
dc.subjectIMHOFFes_PE
dc.titleDiseño del sistema de evacuación de aguas residuales y planta de tratamiento mediante tanque Imhoff en el Centro Poblado San Martín de CP3, Tambogrande, Piura 2021es_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.grantorUniversidad Privada Antenor Orrego. Facultad de Ingenieriaes_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.disciplineIngenieria Civiles_PE
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#2.01.00es_PE
renati.advisor.orcidhttps://orcid.org/0000-0001-8871-2368es_PE
renati.author.dni45700631
renati.advisor.dni42747486
renati.typehttp://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttp://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.discipline732016es_PE
renati.jurorNarváez Aranda, Ricardo Andrés
renati.jurorCabanillas Quiroz, Guillermo Juan
renati.jurorFarfán Córdova, Marlon Gastón
dc.publisher.countryPEes_PE


Files in this item

Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/closedAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/closedAccess