Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/20.500.12759/1924
Título : Eficacia del localizador apical DPEX I en pacientes que se atienden en la Clínica Estomatológica de la Universidad Privada Antenor Orrego, 2015
Autor : Crispin Salinas, Anne Lizbeth
Asesor: Espinoza Salcedo, Maria Victoria
Palabras clave : Exodoncia
Localizador apical
Fecha de publicación : 2016
Institución : Universidad Privada Antenor Orrego - UPAO
Resumen : El presente estudio, tuvo como objetivo determinar el nivel de eficacia del locaapical DPEX I en pacientes que acudieron en la Clínica Estomatológica Universidad Privada Antenor Orrego, 2015. Se seleccionaron 30 pacientes que acudieron a la Clínica Estomatológica,requirieron tratamiento de exodoncia, se le explicó la importancia y los objetivla presente investigación para que tomen la decisión de participar de voluntaria. Firmando el consentimiento informado. Se respetó el protocolo determinar la conductometría en piezas anteriores y se empleó el localizador DPEX I. La longitud de trabajo fue considerada aceptable, cuando el locamarcaba que estaba entre 0.5-1.5 mm del foramen y corto cuando estaba a m1.5 mm del foramen apical. El rango de tolerancia fue de +/- 0.5 mm. Los resultados nos mostraron que el localizador DPEX I obtuvo un 73,3precisión demostrando claramente su eficacia en la determinación de la longtrabajo. Concluyendo, que la exactitud del localizador de ápices DPEX I fue óptima.
This study aimed to determine the level of effectiveness of apical locator DPEX I in patients attending the Clinic Stomatology Antenor Orrego Private University, 2015. 30 patients who came to the dental clinic, requiring extraction treatment, he explained the importance and objectives of this research to take the decision to participate voluntarily selected. By signing the informed consent. The protocol was respected to determine the radiograph in previous parts and the apical locator DPEX I. The working length was used was considered acceptable when the locator was marked between 0.5-1.5 mm short of the foramen and when it was more than 1.5 mm the apical foramen. The tolerance range of +/- 0.5 mm was. The results showed us that the locator DPEX I obtained 73.3% accuracy clearly demonstrating its effectiveness in determining the working length. Concluding that the accuracy of apex locator DPEX I was optimal.
URI : https://hdl.handle.net/20.500.12759/1924
Aparece en las colecciones: Estomatología

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
REP_ESTO_ANNE.CRISPIN_EFICACIA.LOCALIZADOR.APICAL.DPEX.I.PACIENTES.ATIENDEN.CLÍNICA.ESTOMATOLÓGICA.UNIVERSIDAD.PRIVADA.ANTENOR.ORREGO.2015.pdfANNE.CRISPIN_EFICACIA.LOCALIZADOR.APICAL.DPEX.I.PACIENTES.ATIENDEN.CLÍNICA.ESTOMATOLÓGICA.UNIVERSIDAD.PRIVADA.ANTENOR.ORREGO.20152,28 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.