dc.description.abstractEl presente proyecto de investigación, titulado: “INFLUENCIA DEL ADHESIVO EPOXICO COLMA FIX 32 COMO PUENTE ADHERENTE EN VIGAS DE CONCRETO ARMADO SUJETAS A FLEXION PARA LA RECUPERACION DE SU MONOLITISMO”, cuyo objetivo principal es brindar importante información acerca de la influencia que tiene un adhesivo epóxico en específico aplicado como puente adherente entre concretos de diferentes edades, realizando una prueba en el Laboratorio de Resistencia de Materiales de la UNIVERSIDAD PRIVADA ANTENOR ORREGO. Esta prueba se caracteriza por el uso de una maquina universal de carga artesanal no reglamentada, el empleo de tres deformímetros para obtener las medidas necesarias y realizar el procesamiento de datos, también la construcción de tres vigas de concreto armado (una viga sin adhesivo, una con adhesivo sobre el eje neutro, y otra bajo el eje neutro) cuya característica es la altura a la que se ubica el Puente adherente. Dichas vigas se someterán a la aplicación de una carga, repartida en dos cargas puntuales, teniendo como resultado una zona de flexión pura. Los datos obtenidos nos brindan resultados comparativos entre la viga patrón (monolítica – sin adhesivo) y las dos restantes con adhesivo. Finalmente se brindara las conclusiones obtenidas de dicho ensayo de laboratorio, determinando cual es la influencia del adhesivo ColmaFix 32, al someter al elemento estructural a fuerzas externas.es_PE
dc.description.abstractThe present research “INFLUENCIA DEL ADHESIVO EPOXICO COLMA FIX 32 COMO PUENTE ADHERENTE EN VIGAS DE CONCRETO ARMADO SUJETAS A FLEXION PARA LA RECUPERACION DE SU MONOLITISMO”, has the principal objective to provide an important information about the influence that has an specific epoxy adhesive applied as an adhesive bridge between concrete of different ages, doing a test on the Laboratory of Strenght Materials of the UPAO university. This test is characterized by the use of a universal loading machine unregulated and artisanal, the use of gages to obtain measures and perform the data processing, also the buiding of three beams of reinforced concrete (a beam without adhesive, a beam with adhesive on the neutral axis, and another under the neutral axis) which characteristic is the height to which the bonding bridge is located. These beams are subject to the application of a load distribute over two points charges, resulting in a zone of pure flexion. The obtained data give us comparative results between the beam pattern (monolithic – no adhesive) and the two remaining with adhesive. Finally we offer the conclusions obtained from the laboratory test, determining which is the influence of the adhesive ColmaFix 32, submiting the structural element to external forces.en_US
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada Antenor Orrego - UPAOes_PE
dc.relation.ispartofseriesT_ING.CIVIL_1325
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.sourceUniversidad Privada Antenor Orregoes_PE
dc.sourceRepositorio Institucional - UPAOes_PE
dc.subjectUso adhesivoes_PE
dc.subjectPuente adherentees_PE
dc.titleInfluencia del uso de adhesivo epóxico Colmafix 32 como puente adherente en vigas de concreto armado sujetas a flexión para la recuperación de su monolitismoes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.grantorUniversidad Privada Antenor Orrego. Facultad de Ingenieríaes_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.disciplineIngeniería Civiles_PE


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(es)

Mostrar el registro sencillo del ítem