Mostrar el registro sencillo del ítem

dc.contributor.advisorVillarreal Becerra, Einer Neils
dc.contributor.authorRamirez Hidalgo, Gonzalo Rafael
dc.creatorRamirez Hidalgo, Gonzalo Rafael
dc.date.accessioned2018-03-01T15:18:01Z
dc.date.available2018-03-01T15:18:01Z
dc.date.issued2018
dc.identifierT_ESTO_501
dc.identifier.otherT046_45448706.T
dc.identifier.urihttps://hdl.handle.net/20.500.12759/3776
dc.description.abstractComparar el grado de microfiltración in vitro en circunstancias de resina compuesta empleando resina precalentada y cemento resinoso dual autoadhesivo como agente de cementación. Materiales y métodos. El estudio se realizó con 40 premolares, 20 premolares superiores y 20 premolares inferiores sanos, distribuidos al azar en grupo A y B. se realizaron cavidades expulsivas en M.O.D, luego se confeccionaron incrustaciones de resina para luego cementarlas. Al grupo A, fueron cementados con cemento resinoso dual autoadhesivo y el grupo B, con resina compuesta (3M Z250) precalentada a 65° C posteriormente las muestras fueron sumergidas en azul de metileno al 2% durante 24 horas, luego se lavaron, se secaron y se analizaron en un microscopio -estereoscopio con un aumento 40x. Los datos se procesaron en el programa estadístico SPSS versión 24.0 , para luego presentar los resultados en tablas de doble entrada y gráficos, se usó el test chi2. Conclusión: Se concluyó que si existe diferencias significativa en el grado de microfiltración in vitro entre el cemento resinoso dual autoadhesivo y la resina compuesta precalentada, siendo esta última mejor en el sellado marginales_PE
dc.description.abstractTo compare the degree of microfiltration in vitro under circumstances of composite resin using preheated resin and dual self- adhesive resinous cement as a cementing agent. Materials and methods. The study was performed with 40 premolars, 20 upper premolars and 20 healthy lower premolars, distributed randomly in group A and B. Ejection cavities were performed in M.O.D, then resin inlays were made and then cemented. Group A were cemented with self-adhesive dual resinous cement and group B with composite resin (3M Z250) preheated to 65 ° C subsequently the samples were immersed in 2% methylene blue for 24 hours, then washed, dried and they were analyzed in a microscope - stereoscope with a 40x magnification. The data were processed in the statistical program SPSS version 24.0, to then present the results in double entry tables and graphs, the chi2 test was used. Conclusion: It was concluded that there is a significant difference in the degree of in vitro microfiltration between the self-adhesive dual resinous cement and the preheated composite resin, the latter being better in the marginal sealingen_US
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada Antenor Orregoes_PE
dc.relation.ispartofseriesT_ESTO_501
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.sourceUniversidad Privada Antenor Orregoes_PE
dc.sourceRepositorio institucional - UPAOes_PE
dc.subjectMicrofiltraciónes_PE
dc.subjectIn vitroes_PE
dc.titleMicrofiltración in vitro en incrustaciones de resina compuesta empleando resina fotocurable precalentada y cemento resinoso dual autoadhesivo como agente de cementaciónes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.grantorUniversidad Privada Antenor Orrego. Facultad de Medicina Humanaes_PE
thesis.degree.nameCirujano Dentistaes_PE
thesis.degree.disciplineEstomatologíaes_PE


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(es)

Mostrar el registro sencillo del ítem