Mostrar el registro sencillo del ítem

dc.contributor.advisorMoran Guerrero, Victor Manuel
dc.contributor.authorAlarcón Sagástegui, Jhosip Carlos
dc.contributor.authorAsto Pinedo, Jesus Noe
dc.creatorAlarcón Sagástegui, Jhosip Carlos
dc.date.accessioned2018-07-09T21:01:16Z
dc.date.available2018-07-09T21:01:16Z
dc.date.issued2018
dc.identifier.urihttps://hdl.handle.net/20.500.12759/4187
dc.description.abstractEl proyecto, comprende el estudio de reforzamiento estructural de un edificio existente de 10 niveles con disipadores de Fluido Viscoso incorporado en ambas direcciones, El sistema estructural predominante de la edificación en la dirección “X” y “Y” es Muros Estructurales, las placas toman los mayores esfuerzos de la edificación, La cimentación está dado por una platea con una profundidad de desplante de 3.00m un peralte de 0.60m. para controlar el asentamiento. La edificación sin disipadores no cumple la deriva permisible, teniendo un desplazamiento de (0.010 - 0.013) y de acuerdo a la norma peruana sismorresistente NTE E.030, el máximo es de 0.007. Se estudia la configuración de arreglos de disipador: en diagonal. Asimismo, Se implementó en el modelo virtual disipadores de energía viscosos para lograr un mejor desempeño de la estructura mediante los registros tiempo Historia del REDACIS (Red Nacional de Acelerográfos del CISMID). Para poder modelar los disipadores, se realizó un análisis no lineal tiempo historia (FNA), se examinan las respuestas de la estructura empleando disipadores no lineales con exponente α = 0.5, establecido en la Normativa ASCE 7-10 En base a conceptos de energía se presentan las expresiones para calcular el amortiguamiento efectivo necesario de una edificación. Los resultados obtenidos, en el modelo virtual indican que con el empleo de estos dispositivos se puede lograr reducir los desplazamientos en los centros de masa, las derivas de entrepiso, las fuerzas axiales, cortantes y momentos flectores en los elementos estructurales en cada uno de los niveles. En el modelo virtual cumple con los límites de distorsiones de entrepiso de acuerdo a nuestra normativa. Se obtuvieron reducciones promedio en la dirección “X” de 36.43% para los desplazamientos espectrales máximos y de 31% para las fuerzas espectrales en la base de la estructura. Se optó por disipadores Taylor Devices, el total de 3 por cada dirección XX-YY, siendo un total de disipadores de 6 por nivel, ubicados en las esquinas de la estructura, donde presentan mayores aceleraciones.es_PE
dc.description.abstractThe project comprises the study of structural reinforcement of an existing 10-level building with viscous fluid dissipators incorporated in both directions. The predominant structural system of the building in the ““X““ and ““Y““ direction is Structural Walls, the plates take The major efforts of the building, The foundation is given by a platea with a depth of shame of 3.00m a cant of 0.60m. To control the settlement. The building without sinks does not comply with the allowable drift, having a displacement of (0.010 - 0.013) and according to the Peruvian norm NTS E.030 earthquake resistant, the maximum is 0.007. The configuration of heatsink arrangements is studied diagonally. Also, viscous energy dissipators were implemented in the virtual model to achieve a better performance of the structure through the time history records of the REDACIS (National Accelerator Network of CISMID). In order to be able to model the dissipators, we performed a nonlinear time history analysis (FNA),we examine the structure responses using nonlinear dissipators with exponent α = 0.5, established in the ASCE 7-10 Based on energy concepts, expressions are used to calculate the necessary effective damping of a building. The results obtained in the virtual model indicate that with the use of these devices it is possible to reduce the displacements in the centers of mass, the drifts of mezzanine, the axial forces, cutting and bending moments in the structural elements in each one of the Levels. In the virtual model meets the limits of distortions of mezzanine according to our regulations. Average reductions in the ““X““ direction of 36.43% were obtained for the maximum spectral displacements and 31% for the spectral forces at the base of the structure. Taylor Devices dissipators were chosen, the total of 3 for each XX-YY direction, being a total of 6 heaters per level, located in the corners of the structure, where they present greater accelerations.en_US
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada Antenor Orrego - UPAOes_PE
dc.relation.ispartofseriesT_ING.CIVIL_1569
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.sourceUniversidad Privada Antenor Orregoes_PE
dc.sourceRepositorio Institucional - UPAOes_PE
dc.subjectDeriva permisiblees_PE
dc.subjectDisipador Taylor Devicees_PE
dc.titleProyecto de reforzamiento estructural del edificio multifamiliar Los Rosales de 10 niveles con disipadores de fluido viscosoes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.grantorUniversidad Privada Antenor Orrego. Facultad de Ingenieríaes_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.disciplineIngeniería Civiles_PE


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(es)

Mostrar el registro sencillo del ítem