Mostrar el registro sencillo del ítem

dc.contributor.advisorMerino Martínez, Marcelo Edmundo
dc.contributor.authorAlberto Gutiérrez, Alejandro Cristopher
dc.contributor.authorFrias Silva, Bryan Ronaldo
dc.creatorAlberto Gutiérrez, Alejandro Cristopher
dc.date.accessioned2019-05-13T16:10:56Z
dc.date.available2019-05-13T16:10:56Z
dc.date.issued2019
dc.identifier.urihttps://hdl.handle.net/20.500.12759/4787
dc.description.abstractLa presente tesis trata del análisis del módulo de elasticidad mediante el compresometro y el equipo de resonancia, para concreto de alta resistencia F´c 420 Kg/Cm2 usando cemento Inka Tipo ICo adicionado con microfiller calizo, que se utilizan en La Libertad para, concreto Armado, Concreto Reforzado, Concreto Postensado, entre otros y vienen siendo adicionados con diferentes elementos químicos, para lo cual pretende elaborar un comparativa de ensayos destructivos y no destructivos; se presente responder a la interrogante de Cómo será el análisis del módulo de elasticidad mediante el compresometro y el equipo de resonancia. En el procedimiento determinamos el módulo de elasticidad a través del Analizar las características de los agregado fino y agregado grueso, mediante la Norma Técnica Peruana NTP 400.012., Seleccionar el total de especímenes de hormigón necesarias de referencia en la Norma ASTM C 192., Determinar la resistencia a la compresión usando cemento Inka Tipo ICo adicionado con microfiller calizo para el concreto a diseñar F´c=420 kg/cm2. Según la norma. ASTM C31., Determinar el módulo de elasticidad estático del concreto usando la norma. ASTM C38., Determinar el módulo de elasticidad dinámico del concreto se usando la norma. ASTM C215, ASTM C-600, con ensayos no destructivos y Evaluar los resultados mediante los gráficos y tablas comparativas de los testigos a compresión y frecuencia de resonancia. La metodología empleada haciendo una comparativa de resultados, lo que concluirá como un proyecto exploratorio y experimental de datos cuantitativos a través de los equipos de laboratorio. Por ultimo concluiremos con los gráficos comparativos que nos muestran el valor del módulo de elasticidad a 3, 7, 21 y 28 días en diferentes porcentajes de adición para la trabajabilidad del diseño de mezcla de F´c 420 Kg/Cm2.es_PE
dc.description.abstractThis thesis deals with the analysis of the modulus of elasticity by means of the compressor and the resonance equipment, for high strength concrete F 420 cg / cm2 using Inka cement type ICo added with limestone microfiller, which is used in La Libertad for, concrete Armed, Reinforced Concrete, Post-tensioned Concrete, among others and are being added with different chemical elements, for what in turn refers to destructive and non-destructive tests; The question of what the analysis of the elasticity module will be by means of the compresometer and the resonance equipment is answered. In the procedure we determine the modulus of elasticity through the characteristics of the fine aggregate and the coarse aggregate, by means of the Peruvian Technical Norm NTP 400.012., To select the total of specifications of the reference needs in the ASTM C 192 Standard. To determine the resistance compression is used in Inka Type IC cement added with limed microfiller for the concrete to be designed F'c = 420 kg / cm2. According to the norm. ASTM C31. Determine the static elastic modulus of the concrete using the standard. ASTM C38. Determine the dynamic elastic modulus of the concrete the norm is used. ASTM C215, ASTM C-600, with non-destructive tests and evaluate the results through the use of comparative charts and tables of the witnesses at compression and resonance frequency. The methodology used is a comparison of results, which comes as an exploratory and experimental project of quantitative data through laboratory equipment. Finally, we conclude with the comparative graphs that show the value of the modulus of elasticity at 3, 7, 21 and 28 days in different percentages of the performance for the workability of the design of the mix of F'c 420 Kg / Cm2.en_US
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada Antenor Orrego - UPAOes_PE
dc.relation.ispartofseriesT_ING.CIVIL_1716
dc.rightsinfo:eu-repo/semantics/closedAccesses_PE
dc.sourceUniversidad Privada Antenor Orregoes_PE
dc.sourceRepositorio Institucional - UPAOes_PE
dc.subjectMódulo de elasticidades_PE
dc.subjectCompresometroes_PE
dc.subjectConcreto de alta resistenciaes_PE
dc.subjectConcreto armadoes_PE
dc.titleAnálisis del módulo de elasticidad mediante el compresómetro y el equipo de resonancia, para concreto de altaresistencia Fc 420 Kg/cm2 usando cemento Inka tipo Ico adicionado con microfiller calizoes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.grantorUniversidad Privada Antenor Orrego. Facultad de Ingenieríaes_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.disciplineIngeniería Civiles_PE


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(es)

Mostrar el registro sencillo del ítem