dc.description.abstractEn el primer capítulo se relata una introducción a la realidad problemática actual, acerca de la forma deficiente en que se viene realizando actualmente el monitoreo de signos vitales en los hospitales de Trujillo – Perú, por lo cual se plantea como objetivo principal desarrollar un sistema electrónico biomédico portátil, para mejorar el monitoreo y registro histórico de signos vitales de las personas en la ciudad de Trujillo; se plantean la formulación del problema y la justificación de estudio. El segundo capítulo aborda la descripción de los trabajos relacionados al expuesto en la presente tesis, los cuales nos aportaron información relevante como los sensores y microcontroladores utilizados en sus investigaciones, metodologías aplicadas, resultados obtenidos, entre otros factores, asimismo, se detallan los fundamentos del marco teórico y conceptual, así como el planteamiento de la hipótesis y la Operacionalización de las variables. En el tercer capítulo se indica que el desarrollo del trabajo tendrá un nivel de investigación Aplicado con un diseño de contrastación Descriptivo. En el cuarto capítulo, se detallan las pruebas realizadas con sensores elegidos de acuerdo a las especificaciones técnicas del prototipo, como son: sensores de temperatura, sensores de pulso y sensores de oximetría. También se explican los ensayos con distintos módulos central de procesos y con las plataformas de base de datos. Tomando en consideración los resultados de las pruebas llevadas a cabo en el cuarto capítulo, se escogieron los sensores, el módulo central de procesos y la base de datos que mejor se adaptan a los requerimientos técnicos para este sistema electrónico biomédico portátil. Se precisan los métodos para el diseño e implementación de cada una de las etapas de adquisición, análisis, procesamiento y visualización de los datos; pertenecientes al desarrollo del sistema electrónico biomédico portátil. Cabe resaltar que los datos procesados se visualizarán en una App desarrollada exclusivamente para el prototipo. Mediante características de funcionalidad del prototipo se realiza la prueba o contrastación de la hipótesis planteada y se presentan los resultados alcanzados. En el quinto capítulo, se realiza la discusión de resultados obtenidos en base a nuestros indicados del cuadro de operacionalización. Finalmente, del sexto al noveno capítulo, se exponen las conclusiones de la investigación, siendo una de ellas la buena precisión obtenida del prototipo en comparación con instrumentos aprobados por el DIGEMIN, además de las recomendaciones, las referencias bibliográficas y los anexos.es_PE
dc.description.abstractIn the first chapter is related an introduction to the current problematic reality about the deficient way in which the monitoring of vital signs in the hospitals of Trujillo - Peru is being carried out at the moment, for which it’s proposed as a main objective to develop a portable biomedical electronic system, to improve the monitoring and historical registry of vital signs of the people in the city of Trujillo; the formulation of the problem and the justification of study are raised. The second chapter deals with the description of the works related to the one exposed in this thesis, which provided us with relevant information such as the sensors and microcontrollers used in their research, applied methodologies, obtained results, among other factors. Likewise, the foundations of the theoretical and conceptual framework are detailed, as well as the hypothesis approach and the Operationalization of the variables. In the third chapter it’s indicated that the development of the work will have a level of Applied research with a Descriptive contrasting design. In the fourth chapter, it’s detailed the tests carried out with sensors chosen according to the technical specifications of the prototype, such as: temperature sensors, pulse sensors and oximetry sensors. Tests with different central process modules and with database platforms are also explained. Taking into consideration the results of the tests carried out in the fourth chapter, the sensors, the central process module and the database that best fit the technical requirements for this portable biomedical electronic system were chosen. The methods for the design and implementation of each of the stages of data acquisition, analysis, processing and visualization; belonging to the development of the portable biomedical electronic system, are specified. It should be noted that the processed data will be visualized in an App developed exclusively for the prototype. By means of functional characteristics of the prototype, the test or contrast of the hypothesis posed is carried out and the results achieved are presented. In the fifth chapter, we discuss the results obtained based on our indications of the operationalization table. Finally, from the sixth to the ninth chapter, the conclusions of the research are exposed, being one of them the good precision obtained from the prototype in comparison with instruments approved by the DIGEMIN, besides the recommendations, the bibliographic references and the annexes.en_US
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada Antenor Orrego - UPAOes_PE
dc.relation.ispartofseriesT_ING.ELECT_862
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.sourceUniversidad Privada Antenor Orregoes_PE
dc.sourceRepositorio Institucional - UPAOes_PE
dc.subjectSistema electrónico biomédico portátiles_PE
dc.subjectMonitoreo y registro de signos vitaleses_PE
dc.titleDesarrollo de un sistema electrónico biomédico portátil para el monitoreo y registro de signos vitales de las personas en la ciudad de Trujillo – Perúes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.grantorUniversidad Privada Antenor Orrego. Facultad de Ingenieríaes_PE
thesis.degree.nameIngeniero Electrónicoes_PE
thesis.degree.disciplineIngeniería Electrónicaes_PE
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#2.06.02es_PE
renati.advisor.orcidhttps://orcid.org/0000-0002-5220-6292es_PE
renati.author.dni71328679
renati.author.dni70878384
renati.advisor.dni18172856
renati.typehttp://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttp://purl.org/pe-repo/renati/nivel#tituloProfesionales_PE
renati.discipline712026es_PE
renati.jurorAzabache Fernández, Filiberto
renati.jurorTrujillo Silva, Marco
renati.jurorAlvarado Rodríguez, Luis
dc.publisher.countryPEes_PE


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(es)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess