Mostrar el registro sencillo del ítem
Longitud cervical como factor predictor de parto pretérmino
dc.contributor.advisor | Rojas Ruiz, Juan Carlos | |
dc.contributor.author | Cueva Salvatierra, Margarita Marcia | |
dc.creator | Cueva Salvatierra, Margarita Marcia | |
dc.date.accessioned | 2021-05-30T13:00:04Z | |
dc.date.available | 2021-05-30T13:00:04Z | |
dc.date.issued | 2021 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12759/7542 | |
dc.description.abstract | Determinar si la longitud cervical es un factor predictor de parto pretérmino en gestantes con amenaza de parto pretérmino. Material y métodos: Se realizó una investigación de pruebas diagnósticas que abarcó a 150 gestantes que tenían amenaza de parto pretérmino. Se dividió dos grupos: uno con parto pretérmino y el otro grupo sin ello. Se inició analizando el punto de corte de ≤ 25 mm, posteriormente se calculó la curva ROC para encontrar la propuesta de un nuevo punto de corte de longitud cervical corta para diagnóstico de parto pretérmino a través de la ecografía transvaginal, a partir de lo anterior se calculó en ambos puntos de corte la sensibilidad, especificidad, el valor predictivo positivo y negativo, índice de validez y la razón de verosimilitud positiva y negativa. Resultados: Se obtuvieron 74,74% y 87,27%, como resultados para sensibilidad y especificidad de una longitud cervical corta predictora de parto prematuro respectivamente. El valor predictivo positivo y el valor predictivo negativo de la longitud cervical corta fueron 91,03 y 66,67%, respectivamente. En la curva de ROC, el nuevo punto es ≤ 27, 95 mm, cuya sensibilidad, especificidad y valores predictivos positivo y negativo fueron 77,89%, 87,27%, 91,36% y 69,57% respectivamente. La exactitud pronóstica para este nuevo punto de corte a modo de predictor de parto pretérmino fue 84%, siendo una buena precisión diagnóstica. No se evidenciaron mayores diferencias importantes en relación a las variables: nivel educativo, obesidad, talla baja, ni estado civil entre los pacientes con o sin parto pretérmino. Conclusión: La longitud cervical es factor predictor de parto pretérmino en gestantes con amenaza de parto pretérmino. | es_PE |
dc.description.abstract | To determine if cervical length is a predictor of preterm delivery in pregnant women with threatened preterm delivery. Material and methods: An investigation of diagnostic tests was carried out that included 150 pregnant women who had threatened preterm delivery. Two groups were divided: one with preterm delivery and the other group without it. It was started by analyzing the cut-off point of ≤ 25 mm, then the ROC curve was calculated to find the proposal for a new cut-off point of short cervical length for the diagnosis of preterm delivery through transvaginal ultrasound. At both cut-off points, sensitivity, specificity, positive and negative predictive value, validity index, and positive and negative likelihood ratio were calculated. Results: 74.74% and 87.27% were obtained, as results for sensitivity and specificity of a short cervical length predictor of preterm birth, respectively. The positive predictive value and the negative predictive value of short cervical length were 91.03 and 66.67%, respectively. In the ROC curve, the new point is ≤ 27.95 mm, whose sensitivity, specificity and positive and negative predictive values were 77.89%, 87.27%, 91.36% and 69.57% respectively. The prognostic accuracy for this new cut-off point as a predictor of preterm delivery was 84%, being a good diagnostic precision. No major differences were found in relation to the variables: educational level, obesity, short stature, or marital status among patients with or without preterm delivery. Conclusion: Cervical length is a predictor of preterm delivery in pregnant women with threatened preterm delivery. | en_US |
dc.description.uri | Tesis | es_PE |
dc.format | application/pdf | |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Privada Antenor Orrego | es_PE |
dc.relation.ispartofseries | T_MED_2991 | |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | es_PE |
dc.source | Universidad Privada Antenor Orrego | es_PE |
dc.source | Repositorio institucional - UPAO | es_PE |
dc.subject | Parto Pretérmino | es_PE |
dc.subject | Longitud Cervical | es_PE |
dc.title | Longitud cervical como factor predictor de parto pretérmino | es_PE |
dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
thesis.degree.level | Título Profesional | |
thesis.degree.grantor | Universidad Privada Antenor Orrego. Facultad de Medicina Humana | es_PE |
thesis.degree.name | Médico Cirujano | es_PE |
thesis.degree.discipline | Medicina Humana | es_PE |
dc.subject.ocde | http://purl.org/pe-repo/ocde/ford#3.02.27 | es_PE |
renati.advisor.orcid | https://orcid.org/0000-0001-6336-1493 | es_PE |
renati.author.dni | 70465781 | |
renati.advisor.dni | 18122819 | |
renati.type | http://purl.org/pe-repo/renati/type#tesis | es_PE |
renati.level | http://purl.org/pe-repo/renati/level#tituloProfesional | es_PE |
renati.discipline | 912016 | es_PE |
renati.juror | Rodríguez Barboza, Héctor | |
renati.juror | Chaman Castillo, José | |
renati.juror | Ipanaqué Burga, Edward | |
dc.publisher.country | PE | es_PE |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(es)
-
Medicina Humana [2784]