Mostrar el registro sencillo del ítem

dc.contributor.advisorLuján Silva, Enrique Francisco
dc.contributor.authorHuayanay Guzmán, Karen Natalí
dc.contributor.authorMendoza Abramonte, Mario José
dc.creatorHuayanay Guzmán, Karen Natalí
dc.date.accessioned2022-11-09T20:40:52Z
dc.date.available2022-11-09T20:40:52Z
dc.date.issued2022
dc.identifier.urihttps://hdl.handle.net/20.500.12759/9677
dc.description.abstractUno de los principales problemas que afectan a la ciudad de Chulucanas es la polución que genera el tránsito vehicular, debido a la presencia de material fino con presencia de arcillas y limos, a esto se adiciona las precipitaciones generadas en los meses de verano, afectando la transitabilidad y salud de los pobladores del sector comprendido entre C.P. Batanes y C.P. San Pedro. El objetivo principal es estudiar la estabilización de suelos para fines de mejoramiento aplicando el Sistema Consolid en el tramo comprendido entre C.P. Batanes y C.P. San Pedro, provincia de Morropón, departamento de Piura. Se realizó el estudio geológico, estudio geotécnico determinando la muestra más desfavorable C01, se obtuvo un suelo tipo MH limo de alta plasticidad con arena, según SUCS; LL de 55.8, LP de 33.8, IP de 22, contenido de humedad 9.92%, máxima densidad seca 1.782 g/cm3, humedad óptima 10.7%, CBR de 3.3 y 5.6 al 95%, 100%, respectivamente. En el ensayo de ascenso capilar se realizaron 05 probetas con diferentes dosificaciones de Sistema Consolid, el resultado fue un suelo impermeable, se realizó el ensayo proctor modificado y CBR con 04 dosificaciones diferentes, la muestra 01 con CONSOLID 444 al 0.045% y SOLIDRY al 0.5%, muestra 02 con CONSOLID 444 al 0.045% y SOLIDRY al 1.0%, muestra 03 con CONSOLID 444 al 0.045% y SOLIDRY al 1.5%, muestra 04 con CONSOLID 444 al 0.045% y SOLIDRY al 2.0%, obteniendo como dosificación óptima la muestra 04 con valores de máxima densidad seca de 1.870 g/cm3, humedad óptima de 11.1%, CBR de 23.5 y 28.2 al 95 y 100%, respectivamente. Se concluye que la estabilización con Sistema Consolid aumenta considerablemente la máxima densidad seca y CBR.es_PE
dc.description.abstractOne of the main problems affecting the city of Chulucanas is the pollution generated by vehicular traffic, due to the presence of fine material with the presence of clay and silt, in addition to the rainfall generated in the summer months, affecting the trafficability and health of the inhabitants of the sector between Batanes C.P. and San Pedro C.P. The main objective is to study soil stabilization for improvement purposes by applying the Consolid System in the section between Batanes C.P. and San Pedro C.P., province of Morropón, department of Piura. The geological study was carried out, geotechnical study determining the most unfavorable sample C01, a soil type MH silt of high plasticity with sand was obtained, according to SUCS; LL of 55.8, LP of 33.8, IP of 22, moisture content 9.92%, maximum dry density 1.782 g/cm3, optimum moisture 10.7%, CBR of 3.3 and 5.6 at 95%, 100%, respectively. In the capillary rise test, 05 specimens were made with different dosages of Consolid System, the result was an impermeable soil, the modified proctor and CBR test was performed with 04 different dosages, sample 01 with CONSOLID 444 at 0.045% and SOLIDRY at 0.5%, sample 02 with CONSOLID 444 at 0. 045% and SOLIDRY at 1.0%, sample 03 with CONSOLID 444 at 0.045% and SOLIDRY at 1.5%, sample 04 with CONSOLID 444 at 0.045% and SOLIDRY at 2.0%, obtaining as optimum dosage the sample 04 with maximum dry density values of 1.870 g/cm3, optimum humidity of 11.1%, CBR of 23.5 and 28.2 at 95 and 100%, respectively. It is concluded that stabilization with the Consolid System considerably increases the maximum dry density and CBR.en_US
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada Antenor Orrego - UPAOes_PE
dc.relation.ispartofseriesT_ING.CIVILP_029
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/es_PE
dc.sourceUniversidad Privada Antenor Orregoes_PE
dc.sourceRepositorio institucional - UPAOes_PE
dc.subjectEstabilizaciónes_PE
dc.subjectSueloses_PE
dc.subjectSistema Consolides_PE
dc.titleEstudio de estabilización de suelos para fines de mejoramiento aplicando el sistema consolid en el tramo comprendido entre c.p. Batanes y c.p. San Pedro, provincia de Morropón, departamento de Piuraes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.grantorUniversidad Privada Antenor Orrego. Facultad de Ingenieríaes_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.disciplineIngeniería Civiles_PE
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#2.01.01es_PE
renati.advisor.orcidhttps://orcid.org/0000-0001-8960-8810es_PE
renati.author.dni46846096
renati.author.dni72777326
renati.advisor.dni18888927
renati.typehttp://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttp://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.discipline732016es_PE
renati.jurorHenríquez Ulloa, Paúl
renati.jurorGeldres Sánchez, Carmen
renati.jurorVargas López, Segundo
dc.publisher.countryPEes_PE


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(es)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess