Efecto in vitro del hipoclorito de sodio y del silano en la fuerza de adhesión de brackets sobre restauraciones de resina
View/ Open
Download
(application/pdf: 1.585Mb)
(application/pdf: 1.585Mb)
Date
2017Author(s)
Saldivar de la Borda, Claudia Melina
Metadata
Show full item recordAbstract
El propósito de la presente investigación fue evaluar el efecto in vitro del hipoclorito de
sodio al 5.25% y del silano en la fuerza de adhesión de brackets sobre restauraciones de
resina.
Se trabajó con 32 premolares humanos dividiéndolos en 4 grupos aleatoriamente (n=8),
en el Grupo I (control) no se realizaron restauraciones de resina ni pre-
acondicionamiento, en el Grupo II se realizaron la restauraciones de resina y se aplicó
pre-acondicionamiento con silano, en el Grupo III se realizaron restauraciones de resina
y se aplicó pre-acondicionamiento con hipoclorito de sodio al 5.25%, en el Grupo IV se
realizaron restauraciones de resina y se aplicó pre-acondicionamiento con hipoclorito
de sodio al 5.25% más silano. Los brackets fueron adheridos con Transbond XT®; la
resistencia al descementado fue realizada por la ““máquina de ensayos universal de
ensayos mecánicos““. Los resultados fueron obtenidos en Newtons (N) y transformados
en Mega Pascales (MPa), tomando en cuenta la superficie del bracket. Los datos fueron
analizados con las pruebas Kruskal Wallis y U de Mann-Whitney.
Los resultados indicaron que existe diferencia estadísticamente significativa entre los
grupos (p=0.008); Grupo I 18.85 MPa (DE: 2.50), Grupo II 15.18 MPa (DE: 1.99),
Grupo III 18.37 MPa (DE: 1.50), Grupo IV 24.20 MPa (DE: 6.03). The purpose of the present investigation estimated the in vitro effect of sodium
hypochlorite 5.25% and silane on the strength of the adhesion of supports on the resin
restorations.
Group I (control) without resin resurfacing or pre-conditioning was performed in Group
II, the resin restorations were carried out and preconditioned with silane were applied.
In the Group III resin restorations were performed and pre-conditioning with 5.25%
sodium hypochlorite was applied, in Group IV resin restorations were performed and
the pre-conditioning was applied with 5.25% sodium hypochlorite plus silane. The
brackets were adhered with Transbond XT®; Uncovered resistance was performed by
the ““universal test machine of mechanical tests““. The results were obtained in Newtons
(N) and transformed into Mega Pascals (MPa), taking into account the surface of the
bracket. Data were analyzed using the Kruskal Wallis and Mann-Whitney U tests.
The results indicated that the statistically significant difference between groups (p =
0.008); Group I 18.85 MPa (DE: 2.50), Group II 15.18 MPa (DE: 1.99), Group III 18.37
MPa (DE: 1.50), Group IV 24.20 MPa (DE: 6.03).
Collections
- Estomatología [653]