Mostrar el registro sencillo del ítem

dc.contributor.advisorGarcia Rivera, Juan Pablo
dc.contributor.authorChuquiviguel Nureña, Carold Stefanny
dc.contributor.authorRodriguez Alva, Alejandro Jesús
dc.creatorChuquiviguel Nureña, Carold Stefanny
dc.date.accessioned2018-02-07T13:39:20Z
dc.date.available2018-02-07T13:39:20Z
dc.date.issued2017
dc.identifier.urihttps://hdl.handle.net/20.500.12759/3590
dc.description.abstractEn el presente trabajo realizado se propuso evaluar el diseño de una red existente de agua potable sectorizada, en base a sus coeficientes de diseño de rugosidad y variación horaria los cuales fueron calibrados con datos obtenidos de campo. Generalmente los proyectistas toman estos coeficientes de la normatividad vigente y son utilizados en todos los diseños de redes de agua potable en el Perú. Esta red sectorizada está ubicada en la urbanización El Golf y aledaños, la cual se abastece con agua potable subterránea a través de un pozo tubular ubicado en el parque Guillermo Ganoza. Todo esto con la finalidad de evaluar el comportamiento hídrico de la red calibrada respecto a la misma red bajo condiciones normadas. Además, este comportamiento responde a las necesidades de la población, las cuales serán simuladas en diversos escenarios. Como primer desarrollo, se obtuvieron los coeficientes calibrado de “C” y “K2” con datos reales obtenidos de campo. Continuo a esto, se procedió al desarrollo del modelo hidráulico de la red de agua potable sectorizada utilizando los factores establecidos por el RNE como primera alternativa. Una vez establecido el modelo, se procedió a su calibración con los coeficientes obtenidos de la investigación para dar pie a realizar el análisis mediante la simulación de diferentes escenarios hidráulicos. Para el desarrollo de este proyecto se tomó como base estudios y talleres, así como nuestra normativa con el propósito de poder brindar un sustento. Las normas brindadas por el Reglamento Nacional de Edificaciones que se emplearon fueron las siguientes: • Norma OS.030 Almacenamiento de agua para consumo humano. • Norma OS.050 Redes de distribución de agua para consumo humano. • Norma OS.100 Consideraciones básicas de diseño de infraestructura sanitaria. • NTP-ISO 1452-2:2011 (revisada el 2016) Tubos y conexiones de poli cloruro de Vinilo no plastificado (pvc-u) para el Abastecimiento de agua.es_PE
dc.description.abstractIn the present work, it was proposed to evaluate the design of an existing potable water network, based on its roughness and hourly variation coefficients, which were calibrated with field data. Generally the designers take these coefficients of the current normativity and are used in all designs of potable water networks in Peru. This sector network is located in El Golf urbanization and its surroundings, which is supplied with drinking water underground through a tubular well located in Guillermo Ganoza park. All this in order to evaluate the water performance of the network calibrated with respect to the same network under normed conditions. In addition, this behavior responds to the needs of the population, which will be simulated in different scenarios. As a first development, the calibrated coefficients of ““C““ and ““K2““ were obtained with real data obtained from the field. Continued to this, we proceeded to the development of the hydraulic model of the potable water network sectorized using the factors established by the RNE as the first alternative. Once the model was established, its calibration was carried out with the coefficients obtained from the research to give the analysis base by means of the simulation of different hydraulic scenarios. For the development of this project was based on studies and workshops as well as our regulations in order to provide a livelihood. The standards provided by the National Building Regulations that were used were the following: • OS.030 STANDARD storage of water for human consumption. • Standard OS.050 Water distribution networks for human consumption. • Standard OS.100 Basic considerations for health infrastructure design. • NTP-ISO 1452-2: 2011 (revised 2016) Polyvinyl chloride polyvinyl chloride pipes and fittings (pvc-u) for Water Supply.en_US
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada Antenor Orrego - UPAOes_PE
dc.relation.ispartofseriesT_ING.CIVIL_1453
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.sourceUniversidad Privada Antenor Orregoes_PE
dc.sourceRepositorio Institucional - UPAOes_PE
dc.subjectRed existente de aguaes_PE
dc.subjectRugosidades_PE
dc.titleEvaluación del diseño de una red existente de agua potable sectorizada en función de los coeficientes de rugosidad y variación horaria calibradoses_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.grantorUniversidad Privada Antenor Orrego. Facultad de Ingenieríaes_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.disciplineIngeniería Civiles_PE


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(es)

Mostrar el registro sencillo del ítem