Mostrar el registro sencillo del ítem

dc.contributor.advisorCerna Sánchez, Eduardo Elmer
dc.contributor.authorRuiz Ramírez, César Augusto
dc.contributor.authorYarita Suárez, Carlos Noboru
dc.creatorRuiz Ramírez, César Augusto
dc.date.accessioned2021-08-04T23:32:23Z
dc.date.available2021-08-04T23:32:23Z
dc.date.issued2021
dc.identifier.urihttps://hdl.handle.net/20.500.12759/7833
dc.description.abstractEn la actualidad resulta importante comprender diversas soluciones en respuesta a los indicadores sobre un estándar internacional, ello con la situación de poder mejorar la productividad dentro de una empresa. En esa medida, el presente trabajo de investigación comprende un estudio sobre monitoreo del proceso de mantenimiento de grupos electrógenos bajo la normativa ISO 14224, en una central termoeléctrica de la Región Loreto. El objetivo de la investigación fue estimar indicadores de gestión de mantenimiento en los grupos electrógenos con la aplicación de la normativa ISO 14224 de una central termoeléctrica en la región Loreto. Para ello se adquirió como referencia los indicadores de Disponibilidad y Confiabilidad en los grupos electrógenos de centrales termoeléctricas de la región Loreto. El nivel de investigación propuesto en el proyecto fue de tipo documental. Consistió en caracterizar una comparación de Disponibilidad y Confiablidad de los grupos electrógenos en base a registros antecedentes y precedentes. Asimismo, tuvo un diseño descriptivo. Para la presentación de resultados se emplearon tablas, formulas y figuras con las interpretaciones correspondientes. En relación con los resultados previos a la implementación de la Norma ISO 14224, se observó que los niveles mínimos y máximos de disponibilidad fueron 55.88% y 74.83%, además se observó que los niveles mínimos y máximos de confiabilidad fueron 64.65% y 79.75%. En promedio resulto que la disponibilidad fue de 63.45% y la confiabilidad fue de 71.08% en el periodo año 1 y año 2 respectivamente. Posteriormente obtuvimos con la implementación de la Norma ISO 14224, se observó que lo niveles mínimos y máximos de disponibilidad fueron 74.46% y 86.96% y a su vez se observó que los niveles mínimos y máximos de confiabilidad fueron 79.61% y 92.47%. En promedio resulto que la disponibilidad fue 79.57% y la confiabilidad fue de 86.02% en el periodo año 3 y año 4 respectivamente. Por tanto, se comprueba la hipótesis que aplicando la norma ISO 14224 a los grupos electrógenos se mejora de manera significativa los indicadores de disponibilidad y confiabilidad.es_PE
dc.description.abstractAt present it is important to understand various solutions in response to the indicators on an international standard, this with the situation of being able to improve productivity within a company. To that extent, this research work includes a study on monitoring the maintenance process of generators under ISO 14224, in a thermoelectric power plant in the Loreto Region. The objective of the research was to estimate maintenance management indicators in generator sets with the application of ISO 14224 standards of a thermoelectric power plant in the Loreto region. For this purpose, the indicators of Availability and Reliability in the generator sets of thermoelectric power plants in the Loreto region were acquired as a reference. The level of research proposed in the project was documentary. It consisted of characterizing a comparison of Availability and Reliability of the generator sets based on antecedent and precedent records. It also had a descriptive design. For the presentation of results, tables, formulas and figures with the corresponding interpretations were used. In relation to the results prior to the implementation of ISO 14224, it was observed that the minimum and maximum levels of availability were 55.88% and 74.83%, and the minimum and maximum levels of reliability were 64.65% and 79.75%. On average, availability was 63.45% and reliability was 71.08% in year 1 and year 2 period, respectively. Subsequently, with the implementation of ISO 14224, it was observed that the minimum and maximum levels of availability were 74.46% and 86.96% and the minimum and maximum levels of reliability were 79.61% and 92.47%. On average, availability was 79.57% and reliability was 86.02% in year 3 and year 4 period respectively. Therefore, the hypothesis that applying ISO 14224 to generator sets significantly improves availability and reliability indicators is tested.en_US
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada Antenor Orregoes_PE
dc.relation.ispartofseriesT_ELECT_866
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/es_PE
dc.sourceUniversidad Privada Antenor Orregoes_PE
dc.sourceRepositorio institucional - UPAOes_PE
dc.subjectMonitoreoes_PE
dc.subjectGestión de Mantenimientoes_PE
dc.titleMonitoreo del proceso de mantenimiento de grupos electrógenos bajo la normativa ISO 14224, en una central termoeléctrica de la región Loretoes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.grantorUniversidad Privada Antenor Orrego. Facultad de Ingenieríaes_PE
thesis.degree.nameIngeniero Electrónicoes_PE
thesis.degree.disciplineIngeniería Electrónicaes_PE
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#2.11.00es_PE
renati.advisor.orcidhttps://orcid.org/ 0000-0001-5778-2259es_PE
renati.author.dni44607880
renati.author.dni41756983
renati.advisor.dni18216463
renati.typehttp://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttp://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.discipline712026es_PE
renati.jurorAzabache Fernández, Filiberto Melchor
renati.jurorVargas Díaz, Luis Alberto
renati.jurorAlvarado Rodríguez, Luis Enrique
dc.publisher.countryPEes_PE


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(es)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess