Show simple item record

dc.contributor.advisorChavez Diaz, Luis Alberto Erick
dc.contributor.authorBenites García, Irvin Robinson
dc.contributor.authorLozada Gonzales, Gianfranco
dc.creatorBenites Garcia, Irvin Robinson
dc.date.accessioned2022-05-05T02:15:50Z
dc.date.available2022-05-05T02:15:50Z
dc.date.issued2022
dc.identifier.urihttps://hdl.handle.net/20.500.12759/8913
dc.description.abstractLa presente tesis aborda el tema del diseño del sistema de captación, almacenamiento y tratamiento de aguas pluviales para optimizar el consumo de agua de la I, E. Simón Bolívar, Otuzco con la que se formuló como problema general: ¿Cuál es el diseño de captación, almacenamiento y tratamiento de aguas pluviales para optimizar el consumo de agua de la I.E. Simón Bolívar en Otuzco?; siendo el objetivo general “determinar el diseño del sistema de captación, almacenamiento y tratamiento de aguas pluviales para optimizar el consumo de agua del I, E. Simón Bolívar, Otuzco” . El presente trabajo de investigación se desarrolló mediante el método científico, según su finalidad es una investigación aplicada, con un nivel descriptivo correlacional, de diseño no experimental de corte transversal; la población y muestra estudiados son todos los techos de la I.E. Simón Bolívar de Otuzco. Se concluyó que existe las condiciones de las coberturas óptimas para garantizar la captación de aguas pluviales. Los techos son de material impermeable como la calamina y teja andina, con una pendiente mínima del 5%. El sistema de captación de agua de lluvia se realizará mediante canaletas con una eficiencia mínima del 80%. El agua pluvial es transportada mediante canaletas hasta un separador de primeras lluvias. El agua de lluvia llega a las cisternas y luego es elevada el agua pluvial al tanque elevado mediante una electrobomba, con la instalación de dos filtros. El Volumen de almacenamiento es de 147.384 m3, y estarán distribuidas en 4 cisternas de 62.50 m3; 40 m3; 40 m3 y 22.50 m3 de acuerdo a cada una de las actividades que requieran el consumo de agua en la I.E. Simón Bolívar de Otuzco.es_PE
dc.description.abstractThis thesis addresses the theme of the design of the rainwater catchment, storage and treatment system to optimize the water consumption of the I, E. Simón Bolívar, Otuzco with which it was formulated as a general problem: What is the catchment design , storage and treatment of rainwater to optimize EI's water consumption Simón Bolívar in Otuzco ?; the general objective being ““to determine the design of the rainwater collection, storage and treatment system to optimize the water consumption of the I, E. Simón Bolívar, Otuzco““. The present research work was developed through the scientific method, according to its purpose it is applied research, with a correlational descriptive level, of non-experimental cross-sectional design; the population and sample studied are all the ceilings of the I.E. Simón Bolívar de Otuzco. It was concluded that the optimal coverage conditions exist to guarantee the capture of rainwater. The roofs are made of waterproof material such as corrugated iron and Andean tile, with a minimum slope of 5%. The rainwater harvesting system will be made through gutters with a minimum efficiency of 80%. The rainwater is transported through gutters to a separator for the first rains. The rainwater reaches the cisterns and then the rainwater is raised to the elevated tank by means of an electric pump, with the installation of two filters. The storage volume is 147,384 m3, and they will be distributed in 4 tanks of 62.50 m3; 40 m3; 40 m3 and 22.50 m3 according to each of the activities that require the consumption of water in the I.E. Simón Bolívar de Otuzco.en_US
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada Antenor Orregoes_PE
dc.relation.ispartofseriesT_CIVIL_2056
dc.rightsinfo:eu-repo/semantics/closedAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/es_PE
dc.sourceUniversidad Privada Antenor Orregoes_PE
dc.sourceRepositorio institucional - UPAOes_PE
dc.subjectCaptaciónes_PE
dc.subjectAlmacenamiento y Tratamiento de Aguas Pluviales para Optimizar Consumoes_PE
dc.titleDiseño del sistema de captación, almacenamiento y tratamiento de Aguas Pluviales para optimizar el consumo de Agua de la I.E. Simón Bolívar, Otuzcoes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.grantorUniversidad Privada Antenor Orrego. Facultad de Ingenieríaes_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.disciplineIngeniería Civiles_PE
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#2.01.00es_PE
renati.advisor.orcidhttps://orcid.org/0000-0003-0773-9636es_PE
renati.author.dni70828677
renati.author.dni46137298
renati.advisor.dni45426139
renati.typehttp://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttp://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.discipline732016es_PE
renati.jurorVertiz Malabrigo, Manuel
renati.jurorGalicia Guarniz, William
renati.jurorBurgos Sarmiento, Tito
dc.publisher.countryPEes_PE


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/closedAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/closedAccess