dc.description.abstractEsta tesis tiene como objetivo principal constatar y reafirmar la eficiencia que se tiene en la estructura al utilizar el sistema a porticado ante la presencia de un sismo. Se tomo una edificación destinada a ser una POSTA I2, ubicada en el centro poblado de Tuluce, provincia de Huancabamba, departamento de Piura. Esta edificación será construida en un área total de 330 m2 y con un área techada de 306.20 m2. La edificación cuenta con 3 pisos destinados para la atención pública en la salud. El sistema estructural escogido es el sistema aporticado el cual está conformado por pórticos. Para los pisos se utilizaron losas aligeradas de H=20 cm en un solo sentido las cuales se utilizaron con diafragma rígido por nivel. Para la base se conformó con una cimentación llamada Viga de cimentación. El sistema estructural se analizó con las normativas peruanas dadas por el Reglamento Nacional de Edificaciones (RNE), para el análisis sismorresistente se utilizaron todos los parámetros que indica la Norma E.030 en el RNE. Para el modelamiento y análisis de la edificación se utilizaron programas el cual es el ETABS 2016.2.0. Y la cimentación se realizó por el método de elementos finitos de tres nodos utilizamos el programa SAFE 2016 y se comprobó mediante hojas de cálculo. Se realizo el diseño de la estructura teniendo en cuenta los parámetros de la Norma E.060 del RNE las cuales nos otorga como resultados unos desplazamientos contralados en la estructura. Se utilizaron criterios sobre sistema de estructuración para que el uso de esta teoría se haga común, así como lo hacen en el extranjero.es_PE
dc.description.abstractThe main objective of this thesis is to verify and reaffirm the efficiency of the structure when using a porticado in the presence of an earthquake. A building destined to be a medical post I2 was taken, located in the town center of Tuluce, province of Huancabamba, department of Piura. This building will be built on a total area of 330 m2 and have a covered area of 306.20 m2. The building has 3 floors intended for public health care. The chosen structural system is the aporticado System, which is made up of frames. For the floors, lightened slabs of H = 20 cm were used in one direction only, which were used with a rigid diaphragm per level. For the base, he settled for a foundation called the Foundation Beam. All the parameters specified by the E.030 Standard in the RNE were used for the structural system analysis provided by the National Building Regulations (RNE). The ETABS 2016.2.0 program was used for modeling and analysis of the building. And the foundation was made by the three-node finite element method. We used the SAFE 2016 program, and it was verified using spreadsheets. The design of the structure was carried out considering the parameters of the RNE Standard E.060, which gives us controlled displacements as a result. Criteria on seismic protection systems were used so that the use of this theory becomes common, as it is already done abroaden_US
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada Antenor Orregoes_PE
dc.relation.ispartofseriesT_CIVIL_2192
dc.rightsinfo:eu-repo/semantics/closedAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/es_PE
dc.sourceUniversidad Privada Antenor Orregoes_PE
dc.sourceRepositorio Institucional - UPAOes_PE
dc.subjectPostaes_PE
dc.subjectAporticadoes_PE
dc.titleDiseño estructural de una posta aplicando el sistema aporticado de 3 niveles con los parámetros del RNE, en el C.P de Tuluce Dpto. de Piuraes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.grantorUniversidad Privada Antenor Orrego. Facultad de Ingenieríaes_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.disciplineIngeniería Civiles_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.00es_PE
renati.advisor.orcidhttps://orcid.org/0000-0002-1818-6654es_PE
renati.author.dni71530537
renati.advisor.dni16484330
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.discipline732016es_PE
renati.jurorPanduro Alvarado, Elka
renati.jurorVega Benites, Jorge Antonio
renati.jurorVargas Lopez, Segundo Alfredo
dc.publisher.countryPEes_PE


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/closedAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/closedAccess