Diseño estructural de una posta aplicando el sistema aporticado de 3 niveles con los parámetros del RNE, en el C.P de Tuluce Dpto. de Piura
dc.contributor.advisor | Perrigo Sarmiento, Felix Gilberto | |
dc.contributor.author | Arrieta Manzanares, Jhon Anthony | |
dc.creator | Arrieta Manzanares, Jhon Anthony | |
dc.date.accessioned | 2023-01-23T15:58:23Z | |
dc.date.available | 2023-01-23T15:58:23Z | |
dc.date.issued | 2023 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12759/10161 | |
dc.description.abstract | Esta tesis tiene como objetivo principal constatar y reafirmar la eficiencia que se tiene en la estructura al utilizar el sistema a porticado ante la presencia de un sismo. Se tomo una edificación destinada a ser una POSTA I2, ubicada en el centro poblado de Tuluce, provincia de Huancabamba, departamento de Piura. Esta edificación será construida en un área total de 330 m2 y con un área techada de 306.20 m2. La edificación cuenta con 3 pisos destinados para la atención pública en la salud. El sistema estructural escogido es el sistema aporticado el cual está conformado por pórticos. Para los pisos se utilizaron losas aligeradas de H=20 cm en un solo sentido las cuales se utilizaron con diafragma rígido por nivel. Para la base se conformó con una cimentación llamada Viga de cimentación. El sistema estructural se analizó con las normativas peruanas dadas por el Reglamento Nacional de Edificaciones (RNE), para el análisis sismorresistente se utilizaron todos los parámetros que indica la Norma E.030 en el RNE. Para el modelamiento y análisis de la edificación se utilizaron programas el cual es el ETABS 2016.2.0. Y la cimentación se realizó por el método de elementos finitos de tres nodos utilizamos el programa SAFE 2016 y se comprobó mediante hojas de cálculo. Se realizo el diseño de la estructura teniendo en cuenta los parámetros de la Norma E.060 del RNE las cuales nos otorga como resultados unos desplazamientos contralados en la estructura. Se utilizaron criterios sobre sistema de estructuración para que el uso de esta teoría se haga común, así como lo hacen en el extranjero. | es_PE |
dc.description.abstract | The main objective of this thesis is to verify and reaffirm the efficiency of the structure when using a porticado in the presence of an earthquake. A building destined to be a medical post I2 was taken, located in the town center of Tuluce, province of Huancabamba, department of Piura. This building will be built on a total area of 330 m2 and have a covered area of 306.20 m2. The building has 3 floors intended for public health care. The chosen structural system is the aporticado System, which is made up of frames. For the floors, lightened slabs of H = 20 cm were used in one direction only, which were used with a rigid diaphragm per level. For the base, he settled for a foundation called the Foundation Beam. All the parameters specified by the E.030 Standard in the RNE were used for the structural system analysis provided by the National Building Regulations (RNE). The ETABS 2016.2.0 program was used for modeling and analysis of the building. And the foundation was made by the three-node finite element method. We used the SAFE 2016 program, and it was verified using spreadsheets. The design of the structure was carried out considering the parameters of the RNE Standard E.060, which gives us controlled displacements as a result. Criteria on seismic protection systems were used so that the use of this theory becomes common, as it is already done abroad | en_US |
dc.description.uri | Tesis | es_PE |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Privada Antenor Orrego | es_PE |
dc.relation.ispartofseries | T_CIVIL_2192 | |
dc.rights | info:eu-repo/semantics/closedAccess | es_PE |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | es_PE |
dc.source | Universidad Privada Antenor Orrego | es_PE |
dc.source | Repositorio Institucional - UPAO | es_PE |
dc.subject | Posta | es_PE |
dc.subject | Aporticado | es_PE |
dc.title | Diseño estructural de una posta aplicando el sistema aporticado de 3 niveles con los parámetros del RNE, en el C.P de Tuluce Dpto. de Piura | es_PE |
dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
thesis.degree.level | Título Profesional | es_PE |
thesis.degree.grantor | Universidad Privada Antenor Orrego. Facultad de Ingeniería | es_PE |
thesis.degree.name | Ingeniero Civil | es_PE |
thesis.degree.discipline | Ingeniería Civil | es_PE |
dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#2.01.00 | es_PE |
renati.advisor.orcid | https://orcid.org/0000-0002-1818-6654 | es_PE |
renati.author.dni | 71530537 | |
renati.advisor.dni | 16484330 | |
renati.type | https://purl.org/pe-repo/renati/type#tesis | es_PE |
renati.level | https://purl.org/pe-repo/renati/level#tituloProfesional | es_PE |
renati.discipline | 732016 | es_PE |
renati.juror | Panduro Alvarado, Elka | |
renati.juror | Vega Benites, Jorge Antonio | |
renati.juror | Vargas Lopez, Segundo Alfredo | |
dc.publisher.country | PE | es_PE |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(es)
-
Ingeniería Civil [1260]