Mostrar el registro sencillo del ítem

dc.contributor.advisorMedina Carbajal, Lucio Sigifredo
dc.contributor.authorLopez Salazar, Deymer
dc.contributor.authorMendoza Cieza, Henry Nelson
dc.creatorLopez Salazar, Deymer
dc.date.accessioned2023-08-22T13:44:46Z
dc.date.available2023-08-22T13:44:46Z
dc.date.issued2023
dc.identifier.urihttps://hdl.handle.net/20.500.12759/11052
dc.description.abstractLa presente investigación se desarrolló dentro de la ingeniería civil, hidráulica y sanitaria, tuvo como objetivo general Realizar la propuesta de diseño de sistema de saneamiento básico en la localidad de Cocapampa, Distrito de Ocalli Provincia de Luya – Amazonas. La muestra fueron los 225 habitantes de la localidad de Cocapampa. La metodología de investigación se identificó como No Experimental, descriptiva. Los métodos usados fueron las entrevistas, observación directa y revisión de documentos de proyectos similares. Los resultados fue construir 45 módulos de Unidades Básicas de Saneamiento con biodigestor y zanjas de infiltración con un periodo de diseño de 10 años, cada módulo ocupara un área de 3.60 m2 y contara con una dotación de agua de 100 l/hab/dia. La Instalación de los 45 biodigestores de 600 litros contará adicionalmente con un sistema de 2 zanjas de infiltración de 0,60 m de ancho, 0,80 m de profundidad y 5,50 m de largo, también tendrá una pendiente de descarga de 2 % en los tubos de 2” de descarga al largo del tramo de la zanja, así como material filtrante. El presupuesto a nivel de costo directo es de S/. 707,515.73. El diseño de unidades básicas de saneamiento con biodigestor y zanjas de infiltración es la mejor alternativa para su sistema de saneamiento de esta localidad ya que para un sistema de alcantarillado esta sería inviable por la topografía de la zona y las distancias que existe entre las viviendas, este proyecto estará basado en la construcción de una caseta con columnas, muros de ladrillo King Kong asentado tipo soga, vigas collarín, pisos de cerámica, cobertura de calamina, además contara con un inodoro, ducha un lavatorio en su interior, y en el exterior tendrá un lavatorio multiusos. Para la evacuación de las aguas residuales contará con 2 líneas: una tubería de PVC 4” para el inodoro que VI conecta al biodigestor y la otra línea de tubería PVC 2” para aguas grises que se acoplará a la salida del biodigestor que conduce a las zanjas de infiltración. Poseerá tratamiento biológico anaerobio con una eficiencia en remoción de: DBO 94% (15-80 mg/l), DQO 88% (80-190 mg/l), sólidos sedimentables 98% (0,050,3 ml/l) y Ph estabilizado (7,5 – 8,5 UpH). El impacto social en etapa de operación, perfeccionará en corto plazo la calidad del agua potable y eliminación de fuentes de contaminación, con reflejos positivo en la salud de pobladores, también reducción de costos por servicios médicos, reducción de riesgos de morbilidad y mortalidad.es_PE
dc.description.abstractThe present investigation was developed within civil, hydraulic and sanitary engineering, its general objective was to carry out the proposal for the design of a basic sanitation system in the town of Cocapampa, District of Ocalli Province of Luya - Amazonas. The sample was the 225 inhabitants of the town of Cocapampa. The research methodology was identified as Non-Experimental, descriptive. The methods used were interviews, direct observation and review of documents from similar projects. The results were to build 45 modules of Basic Sanitation Units with biodigester and infiltration ditches with a design period of 10 years, each module will occupy an area of 3.60 m2 and will have a water supply of 100 l/inhab/day. The installation of the 45 biodigesters of 600 liters will additionally have a system of 2 infiltration trenches 0.60 m wide, 0.80 m deep and 5.50 m long, it will also have a discharge slope of 2%. in the 2” discharge tubes along the trench section, as well as filter material. The direct cost budget is S/. 707,515.73. The design of basic sanitation units with a biodigester and infiltration ditches is the best alternative for the sanitation system in this locality, since for a sewage system this would be unfeasible due to the topography of the area and the distances that exist between houses. This project will be based on the construction of a booth with columns, rope-type King Kong brick walls, collar beams, ceramic floors, calamine coverage, it will also have a toilet, shower, a sink inside, and outside It will have a multipurpose sink. For the evacuation of wastewater, it will have 2 lines: a 4““ PVC pipe for the toilet that connects to the biodigester and the other 2““ PVC pipe line for gray water that will be coupled to the biodigester outlet that leads to the ditches. of infiltration. It will have anaerobic biological treatment with a removal efficiency of: BOD 94% (15-80 mg/l), COD 88% (80-190 mg/l), settleable solids 98% (0.050.3 ml/l) and stabilized VIII Ph (7.5 – 8.5 UpH). The social impact in the operation stage will improve the quality of drinking water and the elimination of sources of contamination in the short term, with positive effects on the health of residents, as well as reducing costs for medical services, reducing the risks of morbidity and mortality.en_US
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada Antenor Orregoes_PE
dc.relation.ispartofseriesT_CIVIL_2262
dc.rightsinfo:eu-repo/semantics/closedAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/es_PE
dc.sourceUniversidad Privada Antenor Orregoes_PE
dc.sourceRepositorio institucional - UPAOes_PE
dc.subjectSaneamiento Básicoes_PE
dc.subjectUnidades de Saneamientoes_PE
dc.titlePropuesta de diseño de sistema de saneamiento básico en la localidad de Cocapampa, distrito Ocalli, provincia de Luya - Amazonases_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.grantorUniversidad Privada Antenor Orrego. Facultad de Ingenieríaes_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.disciplineIngeniería Civiles_PE
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#2.01.00es_PE
renati.advisor.orcidhttps://orcid.org/0000-0001-5207-4421es_PE
renati.author.dni73219681
renati.author.dni47620511
renati.advisor.dni40534510
renati.typehttp://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttp://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.discipline732016es_PE
renati.jurorNarváez Aranda, Ricardo Andrés
renati.jurorCabanillas Quiroz, Guillermo Juan
renati.jurorSalazar Perales, Álvaro Fernando
dc.publisher.countryPEes_PE


Ficheros en el ítem

Thumbnail
Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(es)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/closedAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/closedAccess