Mostrar el registro sencillo del ítem

dc.contributor.advisorEspinoza Salcedo, María Victoria
dc.contributor.authorCastro Ramirez, Leonor Cristina
dc.creatorCastro Ramirez, Leonor Cristina
dc.date.accessioned2023-11-23T20:08:01Z
dc.date.available2023-11-23T20:08:01Z
dc.date.issued2023
dc.identifier.urihttps://hdl.handle.net/20.500.12759/12051
dc.description.abstractObjetivo: Este estudio buscó evaluar las unidades de polimerización LED polywave (PW) y monowave (MW) sobre la fuerza de unión a la microtracción (µTBS) de las resinas bulk-fill, utilizando tiempos de curado diferentes. Material y método: Se realizó un estudio experimental in vitro, transversal, propectivo, para lo cual se utilizaron terceros molares y se restauraron con las resinas Filtek One Bulk Fill Restorative A2, Tetric® N-Ceram Bulk Fill IVA y Opus Bulk Fill APS A2, cada una fue colocada con su respectivo sistema adhesivo y fueron fotopolimerizados con Elipar Deep cure L (3M ESPE, Saint Paul, EE. UU.) y Valo (Ultradent Products, South Jordan, EE. UU.) en sus tres modos, standard mode, high power mode y extra power mode. Se cortó los dientes obteniendo 15 microbarras por grupo y se midieron con pruebas de microtracción. Los datos se analizaron en el programa SPSS (Statistical Package for the Social Sciences Inc. IBM, NY, USA) versión 24.0. Se realizó análisis descriptivo e inferencial considerando un valor de significancia del 5% (p<0,05) Resultados: Filtek One Bulk Fill, Tetric N-Ceram Bulk y Opus Bulk Fill tuvieron mayor resistencia adhesiva al ser fotocuradas con una lampara monowave, a comparación de la lampara polywave en tres diferentes tiempos y modos de curado. Conclusión: Existen diferencias significativas al comparar la resistencia adhesiva dentinaria al utilizar dos unidades de fotocuradoes_PE
dc.description.abstractObjective: This study sought to evaluate polywave (PW) and monowave (MW) LED curing units on the microtensile bond strength (µTBS) of bulk-fill resins, using different curing times. Material and method: An in vitro, cross-sectional, prospective experimental study was carried out, for which Third molars were used and restored, the resins Filtek One Bulk Fill Restorative A2, Tetric® N-Ceram Bulk Fill IVA and Opus Bulk Fill APS A2 were used, each one was placed with its respective adhesive system and they were light-cured with Elipar Deep cure L (3M ESPE, Saint Paul, USA) and Valo (Ultradent Products, South Jordan, USA) in its three modes, standard mode, high power mode and extra power mode. It was cut from the teeth obtaining 15 microbars per group. Microtensile tests were performed. Data were analyzed using the SPSS program (Statistical Package for the Social Sciences Inc. IBM, NY, USA) version 24.0. Descriptive and inferential analysis was performed considering a significance value of 5% (p<0.05), with a type I error. Results: Filtek One Bulk Fill, Tetric N-Ceram Bulk and Opus Bulk Fill had higher bond strength when light-cured with a monowave lamp compared to the polywave lamp at three different cure times and modes. Conclusion: There are significant differences when comparing dentin adhesive strength when using two light-curing units.es_PE
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada Antenor Orregoes_PE
dc.relation.ispartofseriesM_ESTO_026
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/es_PE
dc.sourceUniversidad Privada Antenor Orregoes_PE
dc.sourceRepositorio Institucionales_PE
dc.subjectLuces de curación dentales_PE
dc.subjectResinas compuestases_PE
dc.subjectResistencia a la tracciónes_PE
dc.titleTiempo de curado en la resistencia adhesiva dentinaria al utilizar dos unidades de fotocuradoes_PE
dc.typeinfo:eu-repo/semantics/masterThesises_PE
thesis.degree.grantorUniversidad Privada Antenor Orrego. Escuela de Postgradoes_PE
thesis.degree.nameMaestra en Estomatología con Mención en Rehabilitación Orales_PE
thesis.degree.disciplineMaestría en Estomatologíaes_PE
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#3.02.14es_PE
renati.advisor.orcidhttps://orcid.org/0000-0001-9408-4396es_PE
renati.author.dni47177633
renati.advisor.dni21547681
renati.typehttp://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttp://purl.org/pe-repo/renati/level#maestroes_PE
renati.discipline911167es_PE
renati.jurorMiranda Gutiérrez, Edward Henry
renati.jurorCáceda Gabancho, Kelly
renati.jurorUlloa Cueva, Teresa Verónica
dc.publisher.countryPEes_PE


Ficheros en el ítem

Thumbnail
Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(es)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess