dc.contributor.advisor | Espinoza Salcedo, Maria Victoria | |
dc.contributor.author | Crispin Salinas, Anne Lizbeth | |
dc.creator | Crispin Salinas, Anne Lizbeth | |
dc.date.accessioned | 2016-10-10T16:57:13Z | |
dc.date.available | 2016-10-10T16:57:13Z | |
dc.date.issued | 2016 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12759/1924 | |
dc.description.abstract | El presente estudio, tuvo como objetivo determinar el nivel de eficacia del locaapical DPEX I en pacientes que acudieron en la Clínica Estomatológica Universidad Privada Antenor Orrego, 2015.
Se seleccionaron 30 pacientes que acudieron a la Clínica Estomatológica,requirieron tratamiento de exodoncia, se le explicó la importancia y los objetivla presente investigación para que tomen la decisión de participar de voluntaria. Firmando el consentimiento informado. Se respetó el protocolo determinar la conductometría en piezas anteriores y se empleó el localizador DPEX I. La longitud de trabajo fue considerada aceptable, cuando el locamarcaba que estaba entre 0.5-1.5 mm del foramen y corto cuando estaba a m1.5 mm del foramen apical. El rango de tolerancia fue de +/- 0.5 mm.
Los resultados nos mostraron que el localizador DPEX I obtuvo un 73,3precisión demostrando claramente su eficacia en la determinación de la longtrabajo.
Concluyendo, que la exactitud del localizador de ápices DPEX I fue óptima. | es_PE |
dc.description.abstract | This study aimed to determine the level of effectiveness of apical locator DPEX I in
patients attending the Clinic Stomatology Antenor Orrego Private University, 2015.
30 patients who came to the dental clinic, requiring extraction treatment, he
explained the importance and objectives of this research to take the decision to
participate voluntarily selected. By signing the informed consent. The protocol was
respected to determine the radiograph in previous parts and the apical locator DPEX
I. The working length was used was considered acceptable when the locator was
marked between 0.5-1.5 mm short of the foramen and when it was more than 1.5
mm the apical foramen. The tolerance range of +/- 0.5 mm was.
The results showed us that the locator DPEX I obtained 73.3% accuracy clearly
demonstrating its effectiveness in determining the working length.
Concluding that the accuracy of apex locator DPEX I was optimal. | en_US |
dc.description.uri | Tesis | es_PE |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Privada Antenor Orrego | es_PE |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | es_PE |
dc.source | Universidad Privada Antenor Orrego | es_PE |
dc.source | Repositorio Institucional - UPAO | es_PE |
dc.subject | Exodoncia | es_PE |
dc.subject | Localizador apical | es_PE |
dc.title | Eficacia del localizador apical DPEX I en pacientes que se atienden en la Clínica Estomatológica de la Universidad Privada Antenor Orrego, 2015 | es_PE |
dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
thesis.degree.level | Título Profesional | es_PE |
thesis.degree.grantor | Universidad Privada Antenor Orrego. Facultad de Medicina Humana | es_PE |
thesis.degree.name | Cirujano Dentista | es_PE |
thesis.degree.discipline | Estomatología | es_PE |
dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#3.02.14 | es_PE |
renati.type | https://purl.org/pe-repo/renati/type#tesis | es_PE |
renati.level | https://purl.org/pe-repo/renati/level#tituloProfesional | es_PE |
renati.discipline | 911016 | es_PE |
dc.publisher.country | PE | es_PE |