dc.contributor.advisor | Durand Orellana, Rocio del Pilar | |
dc.contributor.author | Cruzado Guevara, Jorge Luis | |
dc.contributor.author | Li Zavaleta, Marcelo | |
dc.creator | Cruzado Guevara, Jorge Luis | |
dc.date.accessioned | 2016-11-03T20:59:52Z | |
dc.date.available | 2016-11-03T20:59:52Z | |
dc.date.issued | 2016 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12759/2038 | |
dc.description.abstract | En el presente proyecto de investigación, se trabajó en la comparación de las
resistencias a compresión de testigos de concreto f´c=210 kg/cm2, elaborados con
diferentes tipos de agua (potable, de río y del subsuelo), utilizando cemento
Pacasmayo Extraforte y agregados de la cantera “Gelacho” – Laredo para
determinar su comportamiento mecánico y como este varia. Para llevar a cabo este
proyecto se elaboraron y ensayaron cilindros de concretos a edades de 7, 14 y 28
días con el fin de analizar los distintos resultados y así poder compararlos con los
límites que permite la norma. Al agua se le hicieron estudios físico-químicos para
determinar el tipo de sustancias o agentes contaminantes se encontraban en está
para tener una idea de los efectos que produciría en la resistencia del concreto, los
agregados se caracterizaron y se determinaron sus propiedades físicas.
Seguido a esto se hizo el ensayo de manejabilidad (asentamiento) para medir la
consistencia del concreto fresco, se fabricaron las probetas de concreto variando el
tipo de agua utilizada en diseños de mezcla para 210 kg/cm2 y por último se
realizaron los ensayos de resistencia a la comprensión para corroborar si los
cilindros llegaban a las resistencias esperadas y que variación existe entre estos de
acuerdo al agua utilizada.
Los resultados, indican que el agua subterránea obtuvo la mayor resistencia,
alcanzando la resistencia promedio de 238 kg/cm2, el agua potable alcanzó la
resistencia promedio de 226 kg/cm2, mientras que la resistencia obtenida
utilizando el agua de río Moche fue de 186 kg/cm2, siendo esta la opción menos
apropiada a utilizar en concretos sin previo tratamiento. | es_PE |
dc.description.abstract | In this research project, working on comparing the compressive strength of
concrete witnesses fc = 210 kg / cm2, made with different types of water
(drinking, river and groundwater), using Pacasmayo cement Extraforte and
aggregates quarry “Gelacho” - Laredo to determine its mechanical behavior and
how this varies. To carry out this project were developed and tested concrete
cylinders ages 7, 14 and 28 days in order to analyze the different results so you
can compare them to the limits permitted by the standard. Water it became
physical-chemical studies to determine the type of substances or pollutants were
in this to get an idea of the impact it would have on the strength of concrete,
aggregates were characterized and their physical properties were determined.
Following this test handling (settlement) was to measure the consistency of fresh
concrete, concrete specimens were produced by varying the type of water used in
mix designs to 210 kg / cm2 and finally strength tests were performed to
corroborate the understanding reached cylinders if the expected resistance and
variation between these according to the water used.
The results will indicate that groundwater had the highest resistance, reaching the
average strength of 238 kg / cm2, the water reached the average strength of 226
kg / cm2, while the resistance obtained using water Moche river was 186 kg /
cm2, and this is the least appropriate option to use in concrete without treatment. | en_US |
dc.description.uri | Tesis | es_PE |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Privada Antenor Orrego | es_PE |
dc.relation.ispartofseries | T_ING.CIVIL_1338 | |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | es_PE |
dc.source | Universidad Privada Antenor Orrego | es_PE |
dc.source | Repositorio Institucional - UPAO | es_PE |
dc.subject | Análisis comparativo | es_PE |
dc.subject | Resistencia | es_PE |
dc.title | Análisis comparativo de la resistencia de un concreto convencional teniendo como variable el agua utilizada en el mezclado | es_PE |
dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
thesis.degree.level | Título Profesional | es_PE |
thesis.degree.grantor | Universidad Privada Antenor Orrego. Facultad de Ingeniería | es_PE |
thesis.degree.name | Ingeniero Civil | es_PE |
thesis.degree.discipline | Ingeniería Civil | es_PE |
dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#2.01.00 | |
renati.type | https://purl.org/pe-repo/renati/type#tesis | |
renati.level | https://purl.org/pe-repo/renati/level#tituloProfesional | |
dc.publisher.country | PE | es_PE |