Show simple item record

dc.contributor.advisorPajares Ruiz, Herman Homero
dc.contributor.authorRubio Rubio, Erika Geraldine
dc.creatorRubio Rubio, Erika Geraldine
dc.date.accessioned2016-11-10T21:19:52Z
dc.date.available2016-11-10T21:19:52Z
dc.date.issued2016
dc.identifierT_MED_1726
dc.identifier.urihttps://hdl.handle.net/20.500.12759/2072
dc.description.abstractDeterminar si existe asociación entre el desarrollo de Hipoacusia Neurosensorial y el uso de reproductores portátiles de música en estudiantes de Medicina de la Universidad Privada Antenor Orrego, en el período Agosto - Diciembre de 2014. MATERIAL Y MÉTODO: Estudio de casos y controles, retrospectivo, transversal, analítico, con régimen de investigación libre. La población de estudio estuvo constituida por 96 estudiantes de la Facultad de Medicina de la Universidad Privada Antenor Orrego que cumplían con los criterios de inclusión y exclusión establecido en dos grupos: estudiantes con hipoacusia (casos) y los estudiantes que no tienen hipoacusia (controles), en quienes se buscó el hábito de usar reproductores portátiles de música. Los datos se obtuvieron mediante la realización de audiometrías con un audiómetro (modelo Interacoustics AC40; última fecha de calibración: marzo 2014). Posteriormente se les realizó una encuesta, la cual constaba de siete preguntas, además de la anamnesis y examen físico. Los datos fueron analizados con el software IBM SPSS-21.0 y Excel. Se aplicaron pruebas estadísticas; el coeficiente de contingencia y Odds Ratio, para la verificación de hipótesis. RESULTADOS: De los estudiantes analizados el 60.5 % fueron de sexo femenino y el 39.5 % de sexo masculino; las edades estuvieron entre 17 y 24 años; la audiometría demostró que el 20.8% presentaron Hipoacusia Neurosensorial, mientras que el 79.2% no la presentaron. De los 20 que presentaron Hipoacusia, 19 eran usuarios de reproductores portátiles de música y de los 76 que no tuvieron hipoacusia, 64 no eran usuarios de estos reproductores. La intensidad de volumen a la cual se exponen, se encontró que el valor máximo 105 dB y el mínimo 63 dB. El 85.5% de estudiantes, se expone hasta 84 dB y el 14.5% lo hace a más de 84 dB. Los otros estudiantes que no tienen hipoacusia pero que si son usuarios de reproductores portátiles de música, presentan caídas de 5 a 10 dB de su umbral auditivo; el 15.3% en la frecuencia de 2000 Hz, 15.3% en la de 4000 Hz y el 53.8% en la frecuencia de 8000 Hz. CONCLUSIONES: El uso de reproductores portátiles de música está asociado al desarrollo de Hipoacusia Neurosensorial.es_PE
dc.description.abstractDetermine whether there is association or not between the development of sensorineural hearing loss and the use of portable music players in students of the Medicine School at Antenor Orrego Private University during the period August - December 2014. Material and methods: Case-control study, retrospective, transversal, analytical, with freedom to research. The study population consisted of 96 students of the Medicine School at Antenor Orrego Private University, who met the criteria for inclusion and exclusion, and which were divided into two groups: students with hearing loss (cases group) and students who have not hearing loss (control group), in whom the habit sought to use players portable music.. The data were obtained by performing the hearing tests with an audiometer (model Interacoustics AC40; date of last calibration was on March 2014). Then they conducted a survey, which consists of seven questions, in addition to the history and physical examination. Data were analyzed by using SPSS-21.0 and Excel software, statistical tests were applied; the coefficient of contingency and Odds Ratio for hypothesis testing. Results: From the group of students analyzed 60.5% were female and 39.5% male; the ages were between 17 and 24 years; the audiometry showed that 20.8% has sensorineural hearing loss, while 79,2% had not. Of the 20 who presented hearing loss, 19 were users of portable music players and 76 who had not hearing loss, 64 were non users of these widgets. The loudness to which they are exposed was found to be the maximun 105 dB and the minimun 63 dB among those students users of earphones. It was also found that 85.5% exposed to 84 dB and 14.5% to over 84 dB. The other studentes who did not have hearing loss but who are users of portable music players, showed a drop from 5 to10 dB in their hearing threshold; 15.3% , 15.3% , 53.8% in the frequency of 8000 Hz, 4000 Hz and 8000 Hz respectively. Conclusions: The use of portable music players (PMP) is associated with sensorineural hearing loss development.en_US
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada Antenor Orregoes_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/es_PE
dc.sourceUniversidad Privada Antenor Orregoes_PE
dc.sourceRepositorio Institucional - UPAOes_PE
dc.subjectHipoacusia Neurosensoriales_PE
dc.subjectReproductores portatiles de Musicaes_PE
dc.titleHipoacusia asociada al uso de reproductores portatiles de musica en estudiantes de Medicinaes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.grantorUniversidad Privada Antenor Orrego. Facultad de Medicina Humanaes_PE
thesis.degree.nameMédico Cirujanoes_PE
thesis.degree.disciplineMedicina Humanaes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.02.27es_PE
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.discipline912016es_PE
dc.publisher.countryPEes_PE


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess