Show simple item record

dc.contributor.advisorCisneros Gómez, Carlos Augusto
dc.contributor.authorPomatanta Díaz, Renzo Renato
dc.creatorPomatanta Díaz, Renzo Renato
dc.date.accessioned2024-03-20T16:22:42Z
dc.date.available2024-03-20T16:22:42Z
dc.date.issued2024
dc.identifier.urihttps://hdl.handle.net/20.500.12759/24971
dc.description.abstractObjetivo: Determinar si en pacientes con diagnóstico de ojo seco evaporativo el tratamiento con luz pulsada intensa es más efectivo que el tratamiento convencional. Métodos: Estudio con diseño de cohorte retrospectivo y observacional. La población diana consistió en pacientes con diagnóstico de ojo seco evaporativo, y la población accesible incluyó a aquellos que acudieron a la clínica Oftalmocenter entre enero de 2021 y diciembre de 2022 y fueron diagnosticados con esta condición. Se establecieron criterios de inclusión y exclusión para conformar dos cohortes: Cohorte 1 (48 pacientes), que recibió tratamiento con LPI, y Cohorte 2 (48 pacientes), que recibió tratamiento convencional. Se recopilaron datos clínicos y oftalmológicos, incluyendo el Índice de sintomatología del ojo seco (OSDI), tiempo de ruptura de película lagrimal (NIKBUT), meibografía y enrojecimiento conjuntival. Resultados: Dentro de los resultados se encontró una mayor proporción de mujeres en el grupo de tratamiento con luz pulsada intensa en relación a hombres (41,67% vs 14,58%; p = 0,003). Las variables OSDI (38,35 ± 13,60 vs 48,77 ± 17,35; p = 0,001) y M2 (2,23 ± 0,74 vs 1,84 ± 0,68; p = 0,009) en el pretratamiento resultaron con diferencias estadísticamente significativas; y en el postratamiento, el OSDI (30,90 ± 18,30 vs 39,56 ± 20,75; p = 0,032) y el M2 (2,13 ± 0,83 vs 1,78 ± 0,72; p = 0,027) mantuvieron las diferencias, aunque entre el pretratamiento y postratamiento disminuyeron los valores de OSDI y M2. Dentro de la seguridad del tratamiento con LPI, solo dos pacientes de la cohorte 1 presentaron leve enrojecimiento facial que cedió a las 24 horas. Conclusión: Este estudio sugiere que el tratamiento con LPI podría ser más efectivo que el tratamiento convencional en pacientes con ojo seco evaporativo. Se observaron mejoras en los síntomas y en la morfología de las glándulas de Meibomio en el grupo tratado con LPI. Sin embargo, es necesario más investigaciones y ensayos clínicos para confirmar estos hallazgos y evaluar la seguridad a largo plazo de la LPI en este contextoes_PE
dc.description.abstractObjective: To determine if in patients diagnosed with evaporative dry eye, treatment with intense pulsed light (IPL) is more effective than conventional treatment. Methods: This study employed a retrospective and observational cohort design. The target population consisted of patients diagnosed with evaporative dry eye, and the accessible population included those who attended the Oftalmocenter clinic between January 2021 and December 2022 and were diagnosed with this condition. Inclusion and exclusion criteria were established to form two cohorts: Cohort 1 (48 patients), which received IPL treatment, and Cohort 2 (48 patients), which received conventional treatment. Clinical and ophthalmological data were collected, including the Ocular Surface Disease Index (OSDI), tear film breakup time (NBUT), Meibography, meniscus height, and conjunctival redness. Results: Within the results, a greater proportion of women was found in the intense pulsed light treatment group (41.67% vs 14.58%; p = 0.003). The variables OSDI (38.35 ± 13.60 vs 48.77 ± 17.35; p = 0.001) and M2 (2.23 ± 0.74 vs 1.84 ± 0.68; p = 0.009) in pretreatment They resulted with statistically significant differences; and in the post-treatment, the OSDI (30.90 ± 18.30 vs 39.56 ± 20.75; p = 0.032) and the M2 (2.13 ± 0.83 vs 1.78 ± 0.72; p = 0.027) maintained the differences, although between pre-treatment and post-treatment the OSDI and M2 values decreased. Within the safety of treatment with IPL, only two patients in cohort 1 presented mild facial redness that subsided after 24 hours. Conclusion: This study suggests that IPL treatment may be more effective than conventional treatment in patients with evaporative dry eye. Improvements in symptoms and Meibomian gland morphology were observed in the IPL-treated group. However, further research and clinical trials are needed to confirm these findings and evaluate the long-term safety of IPL in this contextes_PE
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada Antenor Orregoes_PE
dc.relation.ispartofseriesT_MED_3782
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/es_PE
dc.sourceUniversidad Privada Antenor Orregoes_PE
dc.sourceRepositorio Institucional - UPAOes_PE
dc.subjectOjo seco evaporativoes_PE
dc.subjectLuz pulsada intensaes_PE
dc.subjectTratamiento convencionales_PE
dc.titleEfectividad de la luz pulsada intensa en el tratamiento del ojo seco evaporativoes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.grantorUniversidad Privada Antenor Orrego. Facultad de Medicina Humanaes_PE
thesis.degree.nameMédico Cirujanoes_PE
thesis.degree.disciplineMedicina Humanaes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.02.27es_PE
renati.advisor.orcidhttps://orcid.org/0000-0003-1889-3225es_PE
renati.author.dni70747064
renati.advisor.dni17802173
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.discipline912016es_PE
renati.jurorMoreno Ortega, Laura Alejandra
renati.jurorBecerra Suarez, William David
renati.jurorMolina Socola, Juan Carlos
dc.publisher.countryPEes_PE


Files in this item

Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess