dc.description.abstract | El objetivo del presente trabajo es monitorear los signos vitales a pacientes con
insuficiencia cardiaca utilizando un dispositivo móvil, para prevenir posibles problemas
cardiacos.
En principio en el trabajo se describen los aspectos del diseño de investigación y
justificación del estudio, para luego presentar las bases teóricas que permita comprender el
monitoreo de los signos vitales a pacientes con insuficiencia cardiaca. A partir del análisis
de la información obtenida se evalúan aspectos técnicos para realizar el diseño de la interface
para la adquisición de las señales cardiacas haciendo uso del Microcontrolador ESP32 W y
el CI AD8232, su caracterización mediante el acondicionamiento de la señal cardiaca a
través de la implementación de un filtro pasa altos digital para un tiempo de muestreo de
2ms y una frecuencia de corte de 0.1hz y el desarrollo de la interfaz gráfica del aplicativo
móvil se realizó en app inventor.
Por último, se muestra la funcionalidad del dispositivo captando una señal cardiaca con
una frecuencia de 62 pulsaciones por minuto | es_PE |
dc.description.abstract | The objective of this work is to monitor the vital signs of patients with heart failure using
a mobile device, to prevent possible cardiac problems.
Initially, the work describes the aspects of the research design and justification of the
study, and then presents the theoretical bases that allow understanding the monitoring of
vital signs in patients with heart failure. From the analysis of the information obtained,
technical aspects are evaluated to carry out the design of the interface for the acquisition of
cardiac signals using the ESP32 W Microcontroller and the AD8232 IC, its characterization
through the conditioning of the cardiac signal through the implementation of a digital high-
pass filter for a sampling time of 2ms and a cut-off frequency of 0.1hz and the development
of the graphical interface of the mobile application was carried out in app inventor.
Finally, the functionality of the device is shown, capturing a cardiac signal with a
frequency of 62 beats per minute. | es_PE |
dc.description.uri | Tesis | es_PE |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Privada Antenor Orrego | es_PE |
dc.relation.ispartofseries | T_ELECT_900 | |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | es_PE |
dc.subject | Señal Cardiaca | es_PE |
dc.subject | Filtro | es_PE |
dc.title | Monitoreo de signos vitales a través de un dispositivo móvil para personas con síntomas de insuficiencia cardiaca | es_PE |
dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
thesis.degree.grantor | Universidad Privada Antenor Orrego. Facultad de Ingeniería | es_PE |
thesis.degree.name | Ingeniero Electrónico | es_PE |
thesis.degree.discipline | Ingeniería Electrónica | es_PE |
dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#2.11.00 | es_PE |
renati.advisor.orcid | https://orcid.org/0000-0001-9207-8558 | es_PE |
renati.author.dni | 70586264 | |
renati.author.dni | 70314908 | |
renati.advisor.dni | 40545044 | |
renati.type | https://purl.org/pe-repo/renati/type#tesis | es_PE |
renati.level | https://purl.org/pe-repo/renati/level#tituloProfesional | es_PE |
renati.discipline | 712026 | es_PE |
renati.juror | Cerna Sánchez, Eduardo Elmer | |
renati.juror | Ramos Rojas, Ovidio Hildebrando | |
renati.juror | Vargas Diaz, Luis Alberto | |
dc.publisher.country | PE | es_PE |