Mostrar el registro sencillo del ítem

dc.contributor.advisorVertiz Malabrigo, Manuel Alberto
dc.contributor.authorAngulo Ruiz, Elizabeth Cecilia
dc.contributor.authorRodriguez Bocanegra, Jenny Isabel
dc.creatorAngulo Ruiz, Elizabeth Cecilia
dc.date.accessioned2018-02-05T20:38:49Z
dc.date.available2018-02-05T20:38:49Z
dc.date.issued2017
dc.identifier.urihttps://hdl.handle.net/20.500.12759/3572
dc.description.abstractEn el siguiente trabajo de investigación, titulado: “INFLUENCIA DEL EMPOTRAMIENTO DE TUBERIAS SOBRE EL COMPORTAMIENTO ESTRUCTURAL DE LOSAS ALIGERADAS”, expondremos el importante cuidado que se debe de tener cuando la losa aligerada presenta tubería de desagüe. El objetivo principal de esta investigación es poder observar y analizar el comportamiento estructural que presenta una losa aligerada sin tubería con otra losa aligerada que presenta tubería embebida en concreto. Para lo cual se desarrollaron probetas de losas con las dimensiones adecuadas para que pudieran ingresar en la máquina artesanal existente, ya que no existe ninguna normal para los ensayos de losas aligeradas, se adecuo, realizando un ensayo en la cual se midió la deformación de los probetas de losas y a su vez la fuerza que se aplicó a cada losa. Las probetas de losas aligeradas que desarrollamos en la siguiente investigación son: losas aligeradas sin tubería, losas aligeradas con tubería perpendicular a las viguetas, losas aligeradas con tubería paralelas a las viguetas y por último losas aligeradas con tubería perpendicular a las viguetas enrolladas con alambre N° 16. Todas estas losas se elaboraron con un concreto f’c 210 kg/cm 2 ya que mayormente en las edificaciones de nuestro medio se usan esta resistencia.es_PE
dc.description.abstractIn the following research paper, named: ““INFLUENCE OF THE EMBEDDING DUCTS OVER THE STRUCTURAL BEHAVIOR OF THE CORE SLABS““, we will explain the necessary caution to be taken when the core slabs have drain pipes. The aim of this research is to observe and analyze the structural behavior of a core slab without pipe and another one that is fitting a concrete cover slab. For this work we developed prototypes of core slabs with the appropriate dimensions to be able to fit them into the craft machine, since there is no a standard machine for the tests of this core slabs. They were adapted by doing a test in which the deformation and the power of the core slabs prototypes were measured. The core slabs prototypes that we are researching are: core slabs without pipe, core slabs with pipe in perpendicular to the joists, core slabs with pipe in parallel to the joists and finally core slabs with pipe in parallel to the joists wrapped to the wire number 16. All these core slabs were made with a concrete FCK 210, since this strengh is used in the existing buildings.en_US
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada Antenor Orrego - UPAOes_PE
dc.relation.ispartofseriesT_ING.CIVIL_1431
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.sourceUniversidad Privada Antenor Orregoes_PE
dc.sourceRepositorio institucional - UPAOes_PE
dc.subjectEmpotramientoes_PE
dc.subjectComportamiento estructurales_PE
dc.titleInfluencia del empotramiento de tuberías sobre el comportamiento estructural de losas aligeradases_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.grantorUniversidad Privada Antenor Orrego. Facultad de Ingenieríaes_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.disciplineIngeniería Civiles_PE


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(es)

Mostrar el registro sencillo del ítem