Influencia de la tasa de adición del aditivo expansor tipo ettringita- cal en la reducción de contracción y la resistencia a la compresión en concreto para calzaduras
dc.contributor.advisor | Galicia Guarniz, William Conrad. | |
dc.contributor.author | Pairazamán Vásquez, Julio Enrique | |
dc.contributor.author | Zumarán Castro, Luis Alfredo | |
dc.creator | Pairazamán Vásquez, Julio Enrique | |
dc.date.accessioned | 2024-08-08T17:41:44Z | |
dc.date.available | 2024-08-08T17:41:44Z | |
dc.date.issued | 2024 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12759/36831 | |
dc.description.abstract | La presente investigación muestra los resultados del comportamiento de un concreto al cual se le adiciono un aditivo expansor para reducir los efectos de contracción por secado, conjuntamente se evaluó la relación agua cemento en el diseño de mezcla con la finalidad de darle un uso a este concreto hidráulico para obras de sostenimiento provisionales de edificaciones contiguas denominadas calzaduras. El principal problema de la consolidación del concreto para calzaduras, es que la construcción de estas se hace en contra de la acción de la gravedad, cada elemento se elabora debajo del otro, de tal forma que el asentamiento de estas estructuras dependerá de la contracción en las juntas frías de cada nivel de calzaduras. En esta investigación se utilizó un aditivo expansor Sika®IntraPlast®, con una dosificación de 6, 8 y 10 % en peso de cemento, así también se evaluó la relación agua cemento en los niveles 0.35, 0.45 y 0.55, para controlar la resistencia a la compresión sin adicionar ningún aditivo plastificante o reductor de agua, que pueda interferir o interactuar químicamente con el efecto del aditivo expansor, además que representaría un costo innecesario en obras provisionales. Entonces, se realizaron 9 grupos experimentales y 3 de control, se aplicó un diseño factorial 32, para el análisis estadístico de los resultados obtenidos. Concluyendo que, si existe una disminución significativa de la retracción del concreto por efecto de la adición de aditivo expansor, lográndose contrarrestar hasta un 82.83% de este fenómeno a un nivel del 10% de adición de aditivo expansor de dosificación, asimismo a menor relación a/c el efecto de la retracción del concreto es mínimo, consiguiéndose el mínimo valor de retracción con 0.011 a una relación a/c de 0.35 | es_PE |
dc.description.abstract | The present investigation shows the results of the behavior of a concrete to which an expanding additive was added to reduce the effects of drying shrinkage. Overall, the water-cement ratio was evaluated in the design of the mixture with the objective of using this concrete. Hydraulics for temporary works to support adjacent buildings called roads. The main problem with the consolidation of concrete for beds is that its construction is carried out against the action of gravity; each element is carried out under the other, so the settlement of these structures will depend on the contraction in the cold joints at each level of wedges. . In this investigation, an expanding additive Sika®IntraPlast® was used, in doses of 6, 8 and 10% by weight of cement, and the water-cement ratio was also evaluated at levels 0.35, 0.45 and 0.55, to control resistance. Compression without adding any plasticizing or water-reducing additive, which could interfere or chemically interact with the effect of the expanded additive, in addition to representing an unnecessary cost in temporary work. Then 9 experimental groups and 3 control groups were carried out, a 32 factorial design was applied for the statistical analysis of the results obtained. Concluding that, if there is a significant reduction in concrete shrinkage due to the addition of expanding additive, it is possible to neutralize up to 82.83% of this phenomenon at the level of adding 10% of dosed expanding additive, also in a lower proportion than /c the effect of concrete shrinkage is minimal, reaching a minimum shrinkage value of 0.011 with a w/c ratio of 0.35 | es_PE |
dc.description.uri | Tesis | es_PE |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Privada Antenor Orrego | es_PE |
dc.relation.ispartofseries | T_CIVIL_2549 | |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | es_PE |
dc.subject | Calzaduras | es_PE |
dc.subject | Aditivo Expansor | es_PE |
dc.title | Influencia de la tasa de adición del aditivo expansor tipo ettringita- cal en la reducción de contracción y la resistencia a la compresión en concreto para calzaduras | es_PE |
dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
thesis.degree.grantor | Universidad Privada Antenor Orrego. Facultad de Ingenieria | es_PE |
thesis.degree.name | Ingeniero Civil | es_PE |
thesis.degree.discipline | Ingenieria Civil | es_PE |
dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#2.01.00 | es_PE |
renati.advisor.orcid | https://orcid.org/0000-0003-4506-9290 | es_PE |
renati.author.dni | 42152862 | |
renati.author.dni | 73688482 | |
renati.advisor.dni | 41420875 | |
renati.type | https://purl.org/pe-repo/renati/type#tesis | es_PE |
renati.level | https://purl.org/pe-repo/renati/level#tituloProfesional | es_PE |
renati.discipline | 732016 | es_PE |
renati.juror | Vargas López, Segundo Alfredo | |
renati.juror | Medina Carbajal, Lucio Sigifredo | |
renati.juror | Salazar Perales, Álvaro Fernando | |
dc.publisher.country | PE | es_PE |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(es)
-
Ingeniería Civil [1302]