dc.description.abstract | La tesis tiene por objetivo realizar el análisis y diseño estructural de un edificio de
Diez niveles más un semisótano considerando el sistema estructural de muros de
concreto armado, teniendo en cuenta que el edificio a proyectar se encuentra en
el distrito de Pimentel, Chiclayo, por su ubicación se encuentra en una zona de
alta actividad sísmica.
El edificio administrativo a diseñar forma parte de la infraestructura que se está
dotando a la ciudad para las principales actividades económicas y educativas.
Para el análisis estructural del edificio se utilizó el software Etabs como software
principal de análisis, en la cual se realizó el modelo matemático, análisis estático,
análisis dinámico, y análisis modal, con la finalidad de asegurar que los resultados
que arrojan los softwares de análisis se han creado hojas de cálculo puesto que
los programas son herramientas computacionales que ayudan a mejorar la
productividad dentro de un proyecto.
Se realizó el diseño de elementos estructurales como las vigas, a flexión y por
capacidad; las columnas, se diseñaron a flexo compresión y capacidad; las losas
aligeradas, se modelaron en el software Safe y se realizó su posterior diseño en
hojas de cálculo, se verifico las deflexiones y el agrietamiento en losas según se
menciona en la NTP. E060; las losas macizas, se diseñaron a flexión y se verifico
el cortante.
En el diseño de muros estructurales se ha tenido que emplear el software Etabs
para encontrar las solicitaciones, se usó el programa Sap 2000 para encontrar la
profundidad del eje neutro, hojas de cálculo para el diseño de muros a flexo
compresión, y a cortante por capacidad, se diseñaron los elementos de borde.
Por último, se diseñó de la cimentación considerando la normatividad vigente,
escaleras y muros de sótano, después de ello se realizó la ingeniería de detalle
de todos los elementos estructurales, el detalle de acero en cada viga, columnas
y muros de concreto armado, en el caso de muros se realizó la comparación de la
NTP E.060 y el ACI 318.19. en donde podemos apreciar que tenemos que mejorar
los criterios para el confinamiento de elementos de borde. | es_PE |
dc.description.abstract | The objective of the thesis is to carry out the analysis and structural design of a
ten-story building plus a semi-basement considering the structural system of
reinforced concrete walls, taking into account that the building to be designed is
located in the district of Pimentel, Chiclayo, for its Location is in an area of high
seismic activity.
The administrative building to be designed is part of the infrastructure that is being
provided to the city for the main economic and educational activities.
For the structural analysis of the building, the Etabs software was used as the main
analysis software, in which the mathematical model, static analysis, dynamic
analysis, and modal analysis were carried out, in order to ensure that the results
provided by the analysis software Spreadsheets have been created since the
programs are computational tools that help improve productivity within a project.
The design of structural elements such as beams was carried out, for bending and
capacity; The columns were designed for flexo-compression and capacity; The
lightened slabs were modeled in the Safe software and their subsequent design
was carried out in spreadsheets, the deflections and cracking in the slabs were
verified as mentioned in the NTP. E060; The solid slabs were designed in bending
and the shear was verified.
In the design of structural walls, the Etabs software had to be used to find the
stresses, the Sap 2000 program was used to find the depth of the neutral axis,
spreadsheets for the design of flexo-compression walls, and capacity shear, for
example. Lastly, the border elements were designed.
Finally, the foundation was designed considering the current regulations, stairs and
basement walls, after which the detailed engineering of all the structural elements
was carried out, the steel detail in each beam, columns and reinforced concrete
walls, in the case of walls, a comparison was made between NTP E.060 and ACI
318.19, where we can see that we have to improve the criteria for the confinement
of edge elements | es_PE |
dc.description.uri | Tesis | es_PE |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Privada Antenor Orrego | es_PE |
dc.relation.ispartofseries | T_CIVIL_2555 | |
dc.rights | info:eu-repo/semantics/closedAccess | es_PE |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | es_PE |
dc.subject | Muros Estructurales | es_PE |
dc.subject | Análisis Estructural | es_PE |
dc.title | Diseño estructural de un edificio de diez niveles para oficinas, usando muros estructurales en el Distrito de Pimentel, Provincia de Chiclayo | es_PE |
dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
thesis.degree.grantor | Universidad Privada Antenor Orrego. Facultad de Ingenieria | es_PE |
thesis.degree.name | Ingeniero Civil | es_PE |
thesis.degree.discipline | Ingenieria Civil | es_PE |
dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#2.01.00 | es_PE |
renati.advisor.orcid | https://orcid.org/0000-0003-4733-4959 | es_PE |
renati.author.dni | 72203657 | |
renati.advisor.dni | 17983739 | |
renati.type | https://purl.org/pe-repo/renati/type#tesis | es_PE |
renati.level | https://purl.org/pe-repo/renati/level#tituloProfesional | es_PE |
renati.discipline | 732016 | es_PE |
renati.juror | Lopez Carranza, Atilio Ruben | |
renati.juror | Moran Guerrero, Victor Manuel | |
renati.juror | Galicia Guarniz, William Conrad | |
dc.publisher.country | PE | es_PE |