Show simple item record

dc.contributor.advisorMedina Carbajal, Lucio Sigifredo
dc.contributor.authorMelquiades Baca, Santos Elias
dc.contributor.authorZavaleta Gutiérrez, José Antonio
dc.creatorMelquiades Baca, Santos Elias
dc.date.accessioned2024-08-19T15:09:44Z
dc.date.available2024-08-19T15:09:44Z
dc.date.issued2024
dc.identifier.urihttps://hdl.handle.net/20.500.12759/38231
dc.description.abstractSe ha determinado el diseño de la sustitución del concreto normal por el concreto con cascote, en la propiedad mecánica del concreto utilizando cemento portland tipo I. Para lo cual; se tomaron dos diseños de mezclas con relación a/c (0.68) y con un asentamiento de 3”. Se elaboró y curo 25 probetas cilíndricas para cada relación a/c en concordancia a la Norma ASTM C 192 y ASTM C 39. Así mismo se tomó en cuenta los resultados de ensayos con las edades de 7, 14 y 28 días respectivamente. Se realizó el diseño de mezcla para una resistencia a la compresión de f`c 140 kg/cm2; con diseño de mezclas con concreto normal y con concreto de cascote producto de la demolición de vivienda en la zona de Trujillo, conservando la misma relación a/c de 0.68 para ambos diseños; teniendo un valor constante en la cantidad de agregados que se utilizó para el ensayo realizado, así mismo logró determinar que para ambos diseños de mezclas con concreto normal y concreto de cascote en la edad de 7 días (el concreto normal tiene un porcentaje de resistencia a la compresión de 70% a comparación del concreto de cascote se obtuvo 78%), en la edad de 14 días (el concreto normal tiene un porcentaje de resistencia a la compresión de 85% a comparación del concreto de cascote se obtuvo 85%) y finalmente a los 28 días de curado el concreto normal tiene un porcentaje de resistencia a la compresión de 115% a comparación del concreto de cascote se obtuvo 116%. Cabe recalcar que se observó que la Resistencia según las edades antes mencionadas no perjudican a la Resistencia patrón que es de F`C 140 kg/cm2es_PE
dc.description.abstractThe design of the replacement of normal concrete with concrete with rubble has been determined, based on the mechanical property of the concrete using type I Portland cement. For which; Two mix designs were taken with w/c ratio (0.68) and with a slump of 3”. 25 cylindrical specimens were prepared and cured for each w/c ratio in accordance with ASTM C 192 and ASTM C 39. These results in their tests are ages of 7, 14 and 28 days respectively. The mix design was carried out for a compressive strength of f`c 140 kg/cm2; with mixture design with normal concrete and with rubble concrete resulting from the demolition of housing in the Trujillo area, maintaining the same w/c ratio of 0.68 for both designs; having a constant value in the amount of aggregates that was used for the test carried out, it was also possible to determine that for both mixture designs with normal concrete and rubble concrete at the age of 7 days (normal concrete has a compressive strength percentage of 70% compared to rubble concrete, 78% was obtained), at the age of 14 days (normal concrete has a compressive strength percentage of 85%, compared to rubble concrete, 85% was obtained) and finally after 28 days of curing, normal concrete has a compressive strength percentage of 115%, compared to rubble concrete, 116% was obtained. It should be noted that it was observed that the Resistance according to the aforementioned ages does not harm the standard Resistance, which is F`C 140 kg/cm2es_PE
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada Antenor Orregoes_PE
dc.relation.ispartofseriesT_CIVIL_2579
dc.rightsinfo:eu-repo/semantics/closedAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/es_PE
dc.subjectConcretoes_PE
dc.subjectDiseño de Mezclaes_PE
dc.titleDiseño de concreto F`C 140 Kg/cm2 a base de concreto cascote con cemento Portland Tipo I - Trujilloes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.grantorUniversidad Privada Antenor Orrego. Facultad de Ingenieriaes_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.disciplineIngenieria Civiles_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.00es_PE
renati.advisor.orcidhttps://orcid.org/0000-0001-5207-4421es_PE
renati.author.dni70062927
renati.author.dni44188388
renati.advisor.dni40534510
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.discipline732016es_PE
renati.jurorHurtado Zamora, Oswaldo
renati.jurorVelásquez Diaz, Gilberto Anaximandro
renati.jurorPerrigo Sarmiento, Felix Gilberto
dc.publisher.countryPEes_PE


Files in this item

Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/closedAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/closedAccess