dc.contributor.advisorRamal Montejo, Rodolfo Enrique
dc.contributor.authorAtto Renteria, Robert Michael
dc.contributor.authorGarcia Valdiviezo, Erick Javier
dc.creatorAtto Renteria, Robert Michael
dc.date.accessioned2024-08-27T22:27:04Z
dc.date.available2024-08-27T22:27:04Z
dc.date.issued2024
dc.identifier.urihttps://hdl.handle.net/20.500.12759/39771
dc.description.abstractEl presente proyecto de investigación tiene como título “Diseño hidráulico del sistema de agua y alcantarillado del A.H. Nuevo Amanecer con Jesús, del distrito 26 de octubre - Piura”. Ya que hasta el momento no cuentan con estos servicios básicos se optó por realizar dicho proyecto con el objetivo específico de diseñar el sistema de agua potable y alcantarillado en el A.H. Nuevo Amanecer con Jesús para ello se requirió información insitu de la población del A.H. Nuevo Amanecer con Jesús (encuestas), la Población actual, la longitud (Delimitación del terreno), levantamiento topográfico y mecánica de suelos, los cuales nos benefició mucho en el proceso del diseño del sistema de agua y alcantarillado. El A.H. Nuevo Amanecer con Jesús en la actualidad cuenta con una población de 6969 habitantes para el año “0”, el periodo de diseño de 20 años cuya población futura sería 8503 al año “2044”, con una dotación de 220 l/hab/día en zonas urbanas con clima templado y cálido según el RNE, con un caudal promedio diario de 36.591lt/s, también con un caudal máximo horario 50.664lt/s, el volumen del reservorio proyectado es de 880m3, para el sistema de alcantarillado se obtuvieron los siguientes datos tales como caudal máximo diario de 29.712lt/s y el caudal máximo horario de 40.971lt/s. En el modelamiento de agua potable utilizando el programa WaterCAD se logró obtener los siguientes diámetros, red de distribución (PVC-102mm), línea de aducción (PVC-185.4mm), línea de impulsión (HD-300 mm); según normativa lo recomendable sería una presión mínima de 10 m.c.a., con respecto a nuestros resultados nos da una presión mínima de 11.06 m.c.a. y una presión máxima de 21.54 m.c.a. En el modelamiento de alcantarillado empleando el programa de SewerCAD se obtuvo un diámetro de tubería (PVC-192.2mm), sin embargo, se optó por un diámetro de tubería (240.2mm) para enlazar en los Bz-57, Bz-56, Bz-5, Bz- 49, Bz-50, el diámetro de tubería para empalmar el Bz-50 al buzón de descarga es de 302.6mm, según el RNE el valor mínimo del caudal a considerar será de 1.5l/s.es_PE
dc.description.abstractThe present research project is entitled “Hydraulic design of the water system and sewerage of the A.H. Nuevo Amanecer con Jesus, from the district 26 de Octubre - Piura”. Since they do not have these basic services so far, it was chosen to carry out this project with the specific objective of designing the drinking water system and sewerage in the A.H. ‘Nuevo Amanecer con Jesus’ to do this it was required in situ information of the population from the A.H. ‘Nuevo Amanecer con Jesús’ (surveys), the current population, the length (delimitation of the land), topographic survey and mechanics of soils, which greatly benefited us in the process of the water system and sewerage design. The A.H. ‘Nuevo Amanecer con Jesus’ currently has a population of 6969 inhabitants for the year “0”, the design period of 20 years whose future population would be 8503 by the year 2044, with a provision of 220l/inhabitants/day in urban areas with temperate and warm climate according to the RNE IS.010 Population > 2000 inhabitants, with a daily average flow of 36.591lt/s, also with a maximum hourly flow of 50.664lt/ s, the projected reservoir volume is 880m3, the following data for the sewerage system were obtained such as the daily maximum flow of 29.712lt/c and the maximum hourly flow of 40.971lt/d. In the modeling of drinking water using the waterCAD program we managed to obtain the following diameters, distribution grid (PVC-102mm), adduction line (PVC- 185.4mm), propulsion line (HD-300mm); according to regulations, a minimum pressure of 10 m.c.a. would be recommended. Regarding our results, it gives us a minimum pressure of 11.06 m.c.a. and a maximum pressure of 21.54 m.c.a. In the sewerage modeling using the SewerCAD program, a pipe diameter (PVC-192.2mm) was obtained, however, a pipeline diameter (240.2 mm) was chosen to be linked in the bz 57 - bz56 - Bz51- bz49 - BZ50, the pipe diameter to connect bz 50 to the discharge box is 302.6 mm, according to the RNE the minimum flow value to be considered will be 1.5l/ses_PE
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada Antenor Orregoes_PE
dc.relation.ispartofseriesT_CIVILP_;086
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/es_PE
dc.subjectSistema de Agua Potable y Alcantarilladoes_PE
dc.subjectLinea de Impulsiónes_PE
dc.titleDiseño hidráulico del sistema de agua y alcantarillado del A.H. Nuevo Amanecer con Jesús, del distrito 26 de octubre - Piuraes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.grantorUniversidad Privada Antenor Orrego. Facultad de Ingenieriaes_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.disciplineIngenieria Civiles_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.00es_PE
renati.advisor.orcidhttps://orcid.org/0000-0001-9023-6567es_PE
renati.author.dni71077475
renati.author.dni72857535
renati.advisor.dni40025063
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.discipline732016es_PE
renati.jurorNarváez Aranda, Ricardo Andrés
renati.jurorVertiz Malabrigo, Manuel Alberto
renati.jurorPerrigo Sarmiento, Félix Gilberto