dc.description.abstract | El presente proyecto de investigación tiene como título “Diseño hidráulico del
sistema de agua y alcantarillado del A.H. Nuevo Amanecer con Jesús, del distrito
26 de octubre - Piura”. Ya que hasta el momento no cuentan con estos servicios
básicos se optó por realizar dicho proyecto con el objetivo específico de diseñar el
sistema de agua potable y alcantarillado en el A.H. Nuevo Amanecer con Jesús
para ello se requirió información insitu de la población del A.H. Nuevo Amanecer
con Jesús (encuestas), la Población actual, la longitud (Delimitación del terreno),
levantamiento topográfico y mecánica de suelos, los cuales nos benefició mucho
en el proceso del diseño del sistema de agua y alcantarillado. El A.H. Nuevo
Amanecer con Jesús en la actualidad cuenta con una población de 6969 habitantes
para el año “0”, el periodo de diseño de 20 años cuya población futura sería 8503
al año “2044”, con una dotación de 220 l/hab/día en zonas urbanas con clima
templado y cálido según el RNE, con un caudal promedio diario de 36.591lt/s,
también con un caudal máximo horario 50.664lt/s, el volumen del reservorio
proyectado es de 880m3, para el sistema de alcantarillado se obtuvieron los
siguientes datos tales como caudal máximo diario de 29.712lt/s y el caudal máximo
horario de 40.971lt/s.
En el modelamiento de agua potable utilizando el programa WaterCAD se logró
obtener los siguientes diámetros, red de distribución (PVC-102mm), línea de
aducción (PVC-185.4mm), línea de impulsión (HD-300 mm); según normativa lo
recomendable sería una presión mínima de 10 m.c.a., con respecto a nuestros
resultados nos da una presión mínima de 11.06 m.c.a. y una presión máxima de
21.54 m.c.a. En el modelamiento de alcantarillado empleando el programa de
SewerCAD se obtuvo un diámetro de tubería (PVC-192.2mm), sin embargo, se optó
por un diámetro de tubería (240.2mm) para enlazar en los Bz-57, Bz-56, Bz-5, Bz-
49, Bz-50, el diámetro de tubería para empalmar el Bz-50 al buzón de descarga es
de 302.6mm, según el RNE el valor mínimo del caudal a considerar será de 1.5l/s. | es_PE |
dc.description.abstract | The present research project is entitled “Hydraulic design of the water system and
sewerage of the A.H. Nuevo Amanecer con Jesus, from the district 26 de Octubre -
Piura”. Since they do not have these basic services so far, it was chosen to carry
out this project with the specific objective of designing the drinking water system
and sewerage in the A.H. ‘Nuevo Amanecer con Jesus’ to do this it was required in
situ information of the population from the A.H. ‘Nuevo Amanecer con Jesús’
(surveys), the current population, the length (delimitation of the land), topographic
survey and mechanics of soils, which greatly benefited us in the process of the water
system and sewerage design.
The A.H. ‘Nuevo Amanecer con Jesus’ currently has a population of 6969
inhabitants for the year “0”, the design period of 20 years whose future population
would be 8503 by the year 2044, with a provision of 220l/inhabitants/day in urban
areas with temperate and warm climate according to the RNE IS.010 Population >
2000 inhabitants, with a daily average flow of 36.591lt/s, also with a maximum hourly
flow of 50.664lt/ s, the projected reservoir volume is 880m3, the following data for
the sewerage system were obtained such as the daily maximum flow of 29.712lt/c
and the maximum hourly flow of 40.971lt/d.
In the modeling of drinking water using the waterCAD program we managed to
obtain the following diameters, distribution grid (PVC-102mm), adduction line (PVC-
185.4mm), propulsion line (HD-300mm); according to regulations, a minimum
pressure of 10 m.c.a. would be recommended. Regarding our results, it gives us a
minimum pressure of 11.06 m.c.a. and a maximum pressure of 21.54 m.c.a. In the
sewerage modeling using the SewerCAD program, a pipe diameter (PVC-192.2mm)
was obtained, however, a pipeline diameter (240.2 mm) was chosen to be linked in
the bz 57 - bz56 - Bz51- bz49 - BZ50, the pipe diameter to connect bz 50 to the
discharge box is 302.6 mm, according to the RNE the minimum flow value to be
considered will be 1.5l/s | es_PE |
dc.description.uri | Tesis | es_PE |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Privada Antenor Orrego | es_PE |
dc.relation.ispartofseries | T_CIVILP_;086 | |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | es_PE |
dc.subject | Sistema de Agua Potable y Alcantarillado | es_PE |
dc.subject | Linea de Impulsión | es_PE |
dc.title | Diseño hidráulico del sistema de agua y alcantarillado del A.H. Nuevo Amanecer con Jesús, del distrito 26 de octubre - Piura | es_PE |
dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
thesis.degree.grantor | Universidad Privada Antenor Orrego. Facultad de Ingenieria | es_PE |
thesis.degree.name | Ingeniero Civil | es_PE |
thesis.degree.discipline | Ingenieria Civil | es_PE |
dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#2.01.00 | es_PE |
renati.advisor.orcid | https://orcid.org/0000-0001-9023-6567 | es_PE |
renati.author.dni | 71077475 | |
renati.author.dni | 72857535 | |
renati.advisor.dni | 40025063 | |
renati.type | https://purl.org/pe-repo/renati/type#tesis | es_PE |
renati.level | https://purl.org/pe-repo/renati/level#tituloProfesional | es_PE |
renati.discipline | 732016 | es_PE |
renati.juror | Narváez Aranda, Ricardo Andrés | |
renati.juror | Vertiz Malabrigo, Manuel Alberto | |
renati.juror | Perrigo Sarmiento, Félix Gilberto | |
dc.publisher.country | PE | es_PE |