Show simple item record

dc.contributor.advisorMoran Solano, Danny Alexander
dc.contributor.authorRodriguez Pajuelo, Patricia Roxana
dc.creatorRodriguez Pajuelo, Patricia Roxana
dc.date.accessioned2018-04-16T15:38:24Z
dc.date.available2018-04-16T15:38:24Z
dc.date.issued2018
dc.identifier.urihttps://hdl.handle.net/20.500.12759/4012
dc.description.abstractObjetivo: Determinar la capacidad predictiva del test estresante para el diagnóstico de asfixia neonatal en gestaciones a término con oligohidramnios. Material y método: Se realizó un estudio analítico, observacional, retrospectivo, transversal, de pruebas diagnósticas, para determinar la sensibilidad, especificidad, valores predictivos y cocientes de probabilidad del test estresante para predecir asfixia en los recién nacidos, por lo que se incluyeron 153 historias clínicas de gestaciones a término con oligohidramnios atendidas en el Hospital Regional Docente de Trujillo entre los años 2014-2017. Resultados: La prevalencia de asfixia neonatal en gestaciones a término con oligohidramnios fue de 13.41%. La validez predictiva del test estresante tiene una sensibilidad de 81.81%, especificidad de 94.65%, VPP de 72%, VPN de 96.87%, CPP de 15.29 y CPN de 19.21. Conclusiones: El test estresante tiene alta validez predictiva para asfixia neonatal en gestaciones con oligohidramnios.es_PE
dc.description.abstractObjective: To determine the predictive validity of the stress test for neonatal asphyxia in term gestation with oligohydramnios. Methods: An analytical, observational, retrospective, cross-sectional study of diagnostic tests was carried out to determine the sensitivity, specificity, predictive values and likelihood ratios of the stress test to predict asphyxia in newborns, for which 153 clinical records of pregnancies were included. at term with oligohydramnios treated at the Regional Teaching Hospital of Trujillo between 20142017. Results: The prevalence of neonatal asphyxia in term gestation with oligohydramnios was 13.41%. The predictive validity of the stress test has a sensitivity of 81.81%, specificity of 94.65%, PPV of 72%, NPV of 96.87%, CPP of 15.29 and NPC of 19.21. Conclusion: The stressful test has high predictive validity in the diagnosis of neonatal asphyxia in pregnancy with oligohydramnios.en_US
dc.description.uriTesises_PE
dc.formatapplication/pdf
dc.language.isospaes_PE
dc.publisherUniversidad Privada Antenor Orregoes_PE
dc.relation.ispartofseriesT_MED.HUMA_2378
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.sourceUniversidad Privada Antenor Orregoes_PE
dc.sourceRepositorio Institucional - UPAOes_PE
dc.subjectCardiotocografíaes_PE
dc.subjectOligohidramnioses_PE
dc.titleTest estresante como predictor de asfixia neonatal en gestantes a término con oligohidramnioses_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.grantorUniversidad Privada Antenor Orrego. Facultad de Medicina Humanaes_PE
thesis.degree.nameMédico Cirujanoes_PE
thesis.degree.disciplineMedicina Humanaes_PE


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record