dc.description.abstractEn esta investigación se evaluó la Influencia de la adición de un porcentaje de diatomita en el Potencial de Corrosión del Acero A615 embebido en concreto fabricado con Cemento Portland Tipo I y Cemento Portland Extraforte ICo. El propósito de la investigación fue determinar el porcentaje óptimo de diatomita que se debe adicionar en un concreto fabricado con cemento tipo I y cemento extraforte Ico para disminuir el potencial de corrosión del acero embebido en concreto. Los porcentajes de diatomita estudiados fueron de 5, 10 y 20 % en adición al cemento con relación a/c = 0.60, 0.65 y 0.70. Se prepararon probetas de 4x8 pulgadas, que en su interior se introdujo una barra de acero de refuerzo de 5/8 de pulgada de diámetro, con una longitud de 25cm, para evaluar el Potencial de Corrosión de acuerdo a la norma ASTM C876. Así mismo se prepararon probetas de 15x30 cm para el ensayo de resistencia a la compresión según la norma ASTM C109. Los resultados para la relación a/c = 0.60, fabricado con Cemento portland Tipo I, referente al ensayo de compresión, muestran una resistencia aceptable al 10% de adición de diatomita en la estructura del concreto con una resistencia de 189.46 kg/cm , similar a la mezcla del 5% con 188.44 kg/cm 2 , siendo la variación menor al 1%; y para el ensayo de la media celda se muestran que los resultados de los potenciales de corrosión menos negativos se obtuvieron con la adición del 10% de diatomita a los 14 días de secado. Y para la mezcla fabricado con Cemento portland extraforte Ico, referente al ensayo de compresión, muestran una resistencia aceptable al 10% de adición de diatomita en la estructura del concreto con una resistencia de 184.59 kg/cm 2 , similar a la mezcla del 5% con 183.86 kg/cm 2 , siendo la variación menor al 1%; y para el ensayo de la media celda se muestran que los resultados de los potenciales de corrosión menos negativos se obtuvieron con la adición del 10% de diatomita a los 14 y 28 días de secado, no obstante el porcentaje del 5% de adición tiene buenos resultados. Para la relación a/c = 0.65, fabricado con Cemento portland Tipo I, referente al ensayo de compresión, muestran una resistencia aceptable al 5% de adición de diatomita en la estructura del concreto con una resistencia de 172.96 kg/cm 22, similar a la mezcla del 10%.es_PE
dc.description.abstractIn this investigation the influence of the addition of a percentage of diatomite on the corrosion potential of steel A615 embedded in concrete made with Portland Cement Type I and Portland Cement Extraforte ICo was evaluated. The purpose of the research was to determine the optimum percentage of diatomite that must be added in a concrete made with Type I cement and Ico extraforte cement to reduce the corrosion potential of steel embedded in concrete. The percentages of diatomite studied were 5, 10 and 20% in addition to the cement with relation to / c = 0.60, 0.65 and 0.70. We prepared pieces of 4x8 inch, which was introduced in its interior a reinforcing steel bar of 5/8 of an inch in diameter, with a length of 25cm, to assess the potential for corrosion resistance according to ASTM C876. At the same time prepared pieces of 15x30 cm for the test of resistance to the compression according to ASTM C109. The results for the ratio a / c = 0.60, manufactured with Portland Cement Type I, referring to the compression test, show an acceptable resistance to 10% addition of diatomite in the concrete structure with a resistance of 189.46 kg / cm2, similar to the mixture of 5% with 188.44 kg / cm2, the variation being less than 1%; and for the half-cell test it is shown that the results of the less negative corrosion potentials were obtained with the addition of 10% of diatomite after 14 days of drying. And for the mixture made with Cement portland Ico, referring to the compression test, show an acceptable resistance to 10% of addition of diatomite in the concrete structure with a resistance of 184.59 kg / cm2, similar to the mixture of 5% with 183.86 kg / cm2, the variation being less than 1%; and for the half-cell test it is shown that the results of the less negative corrosion potentials were obtained with the addition of 10% of diatomite after 14 and 28 days of drying, however the percentage of 5% addition has good results. For the ratio a / c = 0.65, manufactured with Portland Cement Type I, referring to the compression test, they show an acceptable resistance to 5% addition of diatomite in the concrete structure with a resistance of 172.96 kg / cm2, similar to the mixture of 10% with 172.56 kg / cm2, the variation being less than 1%; and for the half-cell test it is shown that the results of the less negative corrosion potentials were obtained with the addition of 5%en_US
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada Antenor Orregoes_PE
dc.relation.ispartofseriesT_ING.CIVIL_1543
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/es_PE
dc.sourceUniversidad Privada Antenor Orregoes_PE
dc.sourceRepositorio Institucional - UPAOes_PE
dc.subjectDiatomeases_PE
dc.subjectAcero ASTMes_PE
dc.titleInfluencia de la adición de tierra de diatomeas en el potencial de corrosión del acero ASTM A615 dentro del concreto reforzado elaborado con cemento Portland tipo I y cemento tipo ICO en el distrito de Máncora - Piuraes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.grantorUniversidad Privada Antenor Orrego. Facultad de Ingenieríaes_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.disciplineIngeniería Civiles_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.00
renati.typehttps://purl.org/pe-repo/renati/type#tesis
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesional
dc.publisher.countryPEes_PE


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess