Mostrar el registro sencillo del ítem
Validez y confiabilidad del signo del cabeceo en hipoxemia secundaria a infección respiratoria aguda baja en niños menores de 5 años del hospital Víctor Lazarte Echegaray de Trujillo – Perú en el período Octubre – Diciembre del 2013
dc.contributor.advisor | Zavaleta Medina, Segundo Luis | |
dc.contributor.author | Idrogo Aliaga, Lisbeth Teresa | |
dc.creator | Idrogo Aliaga, Lisbeth Teresa | |
dc.date.accessioned | 2014-11-20T23:51:32Z | |
dc.date.available | 2014-11-20T23:51:32Z | |
dc.date.issued | 2014 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12759/424 | |
dc.description.abstract | Determinar la validez y confiabilidad del signo del cabeceo como indicador de hipoxemia en niños menores de 5 años con infección respiratoria aguda baja (IRAB), en el Hospital Víctor Lazarte Echegaray de Trujillo en el período Octubre – Diciembre del 2013; mediante la sensibilidad, especificidad, valor predictivo positivo, valor predictivo negativo y coeficiente kappa. Material y métodos: El estudio corresponde a un diseño transversal, observacional, analítico, prospectivo y de pruebas diagnósticas durante los meses de Octubre a Diciembre del 2013, en el Hospital Víctor Lazarte Echegaray de Trujillo - Perú. La muestra fue seleccionada utilizando los criterios de selección sin excepción. Se definió hipoxemia como una saturación de oxígeno < 95% registrada con la oximetría de pulso, esto se hizo mediante tres puntos de corte (< 94%, < 90%, < 85%). Resultados. Se estudiaron 80 niños menores de 5 años ingresados con diagnóstico de infección respiratoria aguda baja (neumonía y/o bronquiolitis). La incidencia de hipoxemia fue del 56.3%. El signo del cabeceo se encontró en el 25% de los pacientes. Obteniéndose así una sensibilidad del 44.4%, una especificidad del 100%, un valor predictivo positivo del 100%, un valor predictivo negativo del 58.3% y un coeficiente Kappa de 1 (p < 0.05). Además cuando los grados de hipoxemia fueron moderado y severo el 100% de los pacientes presentó el signo (p < 0.005) Conclusiones. El signo del cabeceo no es válido pero si confiable como predictor de hipoxemia en niños menores de 5 años con IRAB. Además se observó una relación inversamente proporcional entre los niveles de saturación de oxígeno y la aparición del signo del cabeceo. | es_PE |
dc.description.abstract | To determine the head nodding sign validity and reliability as a hypoxemia indicator on children with acute lower respiratory infection (ALRI) 5 years old or younger, in the Víctor Lazarte Echegaray Hospital from Trujillo in the period from October to December 2013; through sensibility, specificity, positive predictive value, negative predictive value and Kappa coefficient. Materials and methods: This study corresponds to a transversal, observational, analytic, prospective and diagnostic test design through the period October – December 2013 in Victor Lazarte Echegaray Hospital from Trujillo – Peru. The sample was determined using selection criteria without exception. We defined hypoxemia as an oxygen saturation less than 95% registered on the pulse oxymeter. This was done through three cutoff points (< 94%, < 90%, < 85%). Results: We study 80 children 5 years old or younger diagnosed of acute lower respiratory infection (neumonia and/or bronchiolitis). Hypoxemia cases incidence was 56.3%. The head nodding sign was found on 25% of the total patients. Obtaining a sensibility of 44.4% and a specificity of 100%, a positive predictive value of 100%, a negative predictive value of 58.3% and a Kappa coefficient of 1 (p<0.05). Also with moderate and severe hypoxemia, 100% of the patients showed the head nodding sign (p<0.05). Conclusions: The head nodding sign is not valid nevertheless reliable as a predictor of hypoxemia on children with acute lower respiratory tract infection 5 years old or younger. Also a relation was observed inversely proportional between oxygen saturation and the head nodding sign presence. | en_US |
dc.description.uri | Tesis | es_PE |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Privada Antenor Orrego | es_PE |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | es_PE |
dc.source | Universidad Privada Antenor Orrego | es_PE |
dc.source | Repositorio Institucional - UPAO | es_PE |
dc.subject | Hipoxemia | es_PE |
dc.subject | Infección respiratoria | es_PE |
dc.title | Validez y confiabilidad del signo del cabeceo en hipoxemia secundaria a infección respiratoria aguda baja en niños menores de 5 años del hospital Víctor Lazarte Echegaray de Trujillo – Perú en el período Octubre – Diciembre del 2013 | es_PE |
dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
thesis.degree.level | Título Profesional | es_PE |
thesis.degree.grantor | Universidad Privada Antenor Orrego. Facultad de Medicina Humana | es_PE |
thesis.degree.name | Médico Cirujano | es_PE |
thesis.degree.discipline | Medicina Humana | es_PE |
dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#3.02.27 | es_PE |
renati.type | https://purl.org/pe-repo/renati/type#tesis | es_PE |
renati.level | https://purl.org/pe-repo/renati/level#tituloProfesional | es_PE |
renati.discipline | 912016 | es_PE |
dc.publisher.country | PE | es_PE |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(es)
-
Medicina Humana [2969]