Show simple item record

dc.contributor.advisorCancino Rodas, Cesar Leonidas
dc.contributor.authorBlas Rodriguez, Juan Efrain
dc.contributor.authorVargas Gonzales, Carlos Daniel
dc.creatorBlas Rodriguez, Juan Efrain
dc.date.accessioned2018-11-08T22:54:17Z
dc.date.available2018-11-08T22:54:17Z
dc.date.issued2018
dc.identifier.urihttps://hdl.handle.net/20.500.12759/4454
dc.description.abstractEste informe trata exclusivamente del análisis y diseño estructural de un Coliseo deportivo cerrado para el distrito de Pacasmayo, el cual se desarrollara a partir del proyecto de arquitectura ya realizado. En todo momento del desarrollo de este trabajo, hemos tratado siempre de reflejar el estado del arte actual, en las disciplinas pertinentes de la ingeniería civil y en muchos de los casos se han actualizado trabajos ya hechos frente a la aparición de nuevas especificaciones y nuevas herramientas, sobre todo de orden informático. El análisis y el diseño se han realizado de acuerdo a los requerimientos de las Normas Técnicas Peruanas: NTE E.020 (Cargas), NTE E.030 (Diseño Sismo resistente), NTE E.050 (Suelos y cimentaciones), NTE E.060 (Concreto Armado), NTE E.090 (Estructuras Metálicas), y en lo que corresponda: ACI 31811; AISC 360-11 (Specification for Structural Steel Building). Para el análisis estructural se han usado los programas Sap 2000 y Etabs (programas que toman en cuenta las propiedades únicas inherentes a los modelos matemáticos de la edificación, permitiendo una representación computarizada de la estructura real). Para la respuesta del modelo ante la acción sísmica se usó el método estático y el dinámico seudo espectral. En cuanto al diseño se consideraron vigas de 35 x 70cm. Para cubrir longitudes de 7.20 metros, las vigas están acopladas a un sistema de columnas de 35 x 70. El aligerado es en dos direcciones para cubrir las grandes luces entre vigas. La cimentación se ha diseñado con un sistema de zapatas corridas en forma “T” invertida. Para el caso de la cobertura metálica, se han definido los perfiles basándose en las cargas axiales y siguiendo las normas del AISC 360-11.es_PE
dc.description.abstractThis report is exclusively the analysis and structural design of a closed Sport Coliseum for the District of Pacasmayo, which is developed from the architectural project that was already done. Throughout the development of this work, we have always tried to reflect the state of the art in relevant disciplines of civil engineering and, in many cases, works already done, against the emergence of new tools, especially computer order and new specifications, have been updated. The analysis and design have been made according to the requirements of the Peruvian technical standards: NTE E.020 (Loads), NTE E.030 (Seismic-resistant Design), NTE E.050 (Soils and Foundations), NTE E.060 (Reinforced Concrete), NTE E.090 (Metal Structures), and as appropriate: ACI 318-11; AISC 360-11 (Specification for Structural Steel Building). Structural analysis programs Sap 2000 and Etabs (programs that take into account the unique properties inherent to the mathematical models of the building, allowing a computer representation of the actual structure) have been used. The static method and the pseudo dynamic spectral were used for the response of the model to seismic action. In terms of design, were considered 35 x 70 cm beams. To cover length of 7.20 meters, the beams are attached to a system of 35 x 70 columns. The lightweight is in two directions to cover large lights between beams. The foundation has been designed with footings shaped inverted ““T““ System. In the case of the metal coverage, we have defined profiles based on the axial loads and following the rules of the AISC 360-11.en_US
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada Antenor Orregoes_PE
dc.relation.ispartofseriesT_ING.CIVIL_1614
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/es_PE
dc.sourceUniversidad Privada Antenor Orregoes_PE
dc.sourceRepositorio Institucional - UPAOes_PE
dc.subjectEstructurales_PE
dc.subjectColiseo cerradoes_PE
dc.titleAnálisis y diseño estructural del Coliseo Cerrado Miguel Grau del distrito de Pacasmayo - La Libertades_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.grantorUniversidad Privada Antenor Orrego. Facultad de Ingenieríaes_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.disciplineIngeniería Civiles_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.00
renati.typehttps://purl.org/pe-repo/renati/type#tesis
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesional
dc.publisher.countryPEes_PE


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess