dc.description.abstract | Este informe trata exclusivamente del análisis y diseño estructural de un
Coliseo deportivo cerrado para el distrito de Pacasmayo, el cual se desarrollara
a partir del proyecto de arquitectura ya realizado.
En todo momento del desarrollo de este trabajo, hemos tratado siempre
de reflejar el estado del arte actual, en las disciplinas pertinentes de la ingeniería
civil y en muchos de los casos se han actualizado trabajos ya hechos frente a la
aparición de nuevas especificaciones y nuevas herramientas, sobre todo de
orden informático.
El análisis y el diseño se han realizado de acuerdo a los requerimientos
de las Normas Técnicas Peruanas: NTE E.020 (Cargas), NTE E.030 (Diseño
Sismo resistente), NTE E.050 (Suelos y cimentaciones), NTE E.060 (Concreto
Armado), NTE E.090 (Estructuras Metálicas), y en lo que corresponda: ACI 31811;
AISC 360-11 (Specification for Structural Steel Building). Para el análisis estructural se han usado los programas Sap 2000 y Etabs (programas que toman en cuenta las propiedades únicas inherentes a los
modelos matemáticos de la edificación, permitiendo una representación computarizada de la estructura real).
Para la respuesta del modelo ante la acción sísmica se usó el método
estático y el dinámico seudo espectral. En cuanto al diseño se consideraron vigas
de 35 x 70cm. Para cubrir longitudes de 7.20 metros, las vigas están acopladas
a un sistema de columnas de 35 x 70. El aligerado es en dos direcciones para
cubrir las grandes luces entre vigas. La cimentación se ha diseñado con un
sistema de zapatas corridas en forma “T” invertida. Para el caso de la cobertura
metálica, se han definido los perfiles basándose en las cargas axiales y siguiendo
las normas del AISC 360-11. | es_PE |
dc.description.abstract | This report is exclusively the analysis and structural design of a closed Sport
Coliseum for the District of Pacasmayo, which is developed from the architectural
project that was already done.
Throughout the development of this work, we have always tried to reflect the state
of the art in relevant disciplines of civil engineering and, in many cases, works
already done, against the emergence of new tools, especially computer order and
new specifications, have been updated.
The analysis and design have been made according to the requirements of the
Peruvian technical standards: NTE E.020 (Loads), NTE E.030 (Seismic-resistant
Design), NTE E.050 (Soils and Foundations), NTE E.060 (Reinforced Concrete),
NTE E.090 (Metal Structures), and as appropriate: ACI 318-11; AISC 360-11
(Specification for Structural Steel Building).
Structural analysis programs Sap 2000 and Etabs (programs that take into
account the unique properties inherent to the mathematical models of the
building, allowing a computer representation of the actual structure) have been
used.
The static method and the pseudo dynamic spectral were used for the response
of the model to seismic action. In terms of design, were considered 35 x 70 cm
beams. To cover length of 7.20 meters, the beams are attached to a system of
35 x 70 columns. The lightweight is in two directions to cover large lights between
beams. The foundation has been designed with footings shaped inverted ““T““
System. In the case of the metal coverage, we have defined profiles based on
the axial loads and following the rules of the AISC 360-11. | en_US |
dc.description.uri | Tesis | es_PE |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Privada Antenor Orrego | es_PE |
dc.relation.ispartofseries | T_ING.CIVIL_1614 | |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | es_PE |
dc.source | Universidad Privada Antenor Orrego | es_PE |
dc.source | Repositorio Institucional - UPAO | es_PE |
dc.subject | Estructural | es_PE |
dc.subject | Coliseo cerrado | es_PE |
dc.title | Análisis y diseño estructural del Coliseo Cerrado Miguel Grau del distrito de Pacasmayo - La Libertad | es_PE |
dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
thesis.degree.level | Título Profesional | es_PE |
thesis.degree.grantor | Universidad Privada Antenor Orrego. Facultad de Ingeniería | es_PE |
thesis.degree.name | Ingeniero Civil | es_PE |
thesis.degree.discipline | Ingeniería Civil | es_PE |
dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#2.01.00 | |
renati.type | https://purl.org/pe-repo/renati/type#tesis | |
renati.level | https://purl.org/pe-repo/renati/level#tituloProfesional | |
dc.publisher.country | PE | es_PE |