Mostrar el registro sencillo del ítem

dc.contributor.advisorMerino Martínez, Marcelo Edmundo
dc.contributor.authorFernandez Erazo, Luis Alberto
dc.contributor.authorNuñez Chavarry, Luis Manglio
dc.creatorFernandez Erazo, Luis Alberto
dc.date.accessioned2024-11-05T21:20:42Z
dc.date.available2024-11-05T21:20:42Z
dc.date.issued2024
dc.identifier.urihttps://hdl.handle.net/20.500.12759/47292
dc.description.abstractLa presente tesis tuvo como objetivo general establecer la influencia de la fibra de caucho sobre el concreto Mr = 45kg/cm2 para un pavimento rígido en la ciudad de Trujillo. El método empleado se basó en un enfoque cuantitativo y diseño experimental, en donde se utilizaron técnicas para recolectar datos por observación y experimentación e instrumentos dados por las fichas de observación. Para ello se tomaron muestras con porcentajes de caucho del 1%, 2% y 3% comparado con un diseño de mezcla de concreto tradicional como patrón 280 kg/cm2. Los testigos cilíndricos y de viga de concreto los cuales fueron sometidos a los ensayos del laboratorio, determinaron que el asentamiento mejoró positivamente la trabajabilidad al adicionarle las fibras de caucho, como también la temperatura. Los resultados obtenidos muestran que con la adición de fibra de caucho granulado al 1%, una resistencia a la compresión de 269.40 kg/cm2 y una resistencia a la flexión de 43.51 kg/cm2 a los 28 días; con una adición de fibra de caucho granulado al 2%, se obtuvo una resistencia a la compresión de 258.50 kg/cm2 y una resistencia a la flexión de 53.57 kg/cm2 a los 28 días, finalmente con una adición de fibra de caucho granulado al 3%, se obtuvo una resistencia a la compresión de 241.50 kg/cm2 y una resistencia a la flexión de 40.43 kg/cm2 a los 28 días, lo cual entendiendo que al incorporarle la fibra de caucho granulado al 1% y 3%, estos no cumplen con el diseño requerido para el pavimento rígido con Mr=45 kg/cm2. Finalmente llegando a la conclusión, que al incorporarle la fibra de caucho al 2%, se obtendría el diseño de mezcla de concreto más aceptable, ya que influye la adición de la fibra de caucho granulado en la resistencia del concreto para el diseño del pavimento requeridoes_PE
dc.description.abstractThe general objective of this thesis was to establish the influence of the rubber fiber on the concrete Mr = 45kg/cm2 for a rigid pavement in the city of Trujillo. The method used was based on a quantitative approach and experimental design, where techniques were used to collect data through observation and experimentation and instruments given by observation sheets. For this, samples were taken with rubber percentages of 1%, 2% and 3% compared to a traditional concrete mix design as a 280 kg/cm2 standard. The cylindrical and concrete beam cores, which were subjected to laboratory tests, determined that the settlement positively improved the workability by adding the rubber fibers, as well as the temperature. The results obtained show that with the addition of 1% granulated rubber fiber, a compressive strength of 269.40 kg/cm2 and a flexural strength of 43.51 kg/cm2 at 28 days; with an addition of 2% granulated rubber fiber, a compressive strength of 258.50 kg/cm2 and a flexural strength of 53.57 kg/cm2 was obtained after 28 days, finally with an addition of granulated rubber fiber to the 3%, a compressive strength of 241.50 kg/cm2 and a flexural strength of 40.43 kg/cm2 were obtained after 28 days, understanding that by incorporating granulated rubber fiber at 1% and 3%, these They do not comply with the design required for rigid pavement with Mr=45 kg/cm2. Finally, reaching the conclusion that by incorporating the 2% rubber fiber, the most acceptable concrete mix design would be obtained, since the addition of the granulated rubber fiber influences the resistance of the concrete for the required pavement designes_PE
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada Antenor Orregoes_PE
dc.relation.ispartofseriesT_CIVIL_2617
dc.rightsinfo:eu-repo/semantics/closedAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/es_PE
dc.subjectDiseñoes_PE
dc.subjectMezclaes_PE
dc.titleInfluencia de la fibra de caucho en un concreto Mr=45 kg/cm2 para pavimento rígido en la ciudad de Trujilloes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.grantorUniversidad Privada Antenor Orrego. Facultad de Ingenieriaes_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.disciplineIngenieria Civiles_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.00es_PE
renati.advisor.orcidhttps://orcid.org/0000-0003-4733-4959es_PE
renati.author.dni74963723
renati.author.dni72402373
renati.advisor.dni17983739
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.discipline732016es_PE
renati.jurorDurand Orellana, Rocío del Pilar
renati.jurorSánchez Malpica, Carmen Esperanza
renati.jurorChuquilín Delgado, María Florencia
dc.publisher.countryPEes_PE


Ficheros en el ítem

Thumbnail
Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(es)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/closedAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/closedAccess