dc.description.abstract | Las válvulas de cono fijo, también conocidas como válvulas Howell-Bunger, son
dispositivos utilizados para reducir de forma segura la energía del flujo en presas
de altura media a alta. Estas válvulas dirigen el flujo de salida a un chorro hueco
cónico, lo cual requiere un área amplia para la disipación de energía. El control del
flujo se realiza mediante sistemas de regulación mecánica o hidráulica, y su
funcionamiento requiere un consumo mínimo de energía. El presente trabajo de
investigación tuvo como propósito analizar el comportamiento hidráulico de
prototipos de válvula Howell-Bunger, analizando las diferentes posiciones de la
manga cilíndrica deslizante en condiciones de operación de caudal y salto
hidráulico constantes. Para ambas condiciones de operación análisis, se empleó
ANSYS-CFX como paquete informático de simulación numérica basada en la
Dinámica de los Fluidos Computacional (CFD) para la construcción del modelo.
Para validación, los resultados obtenidos de la simulación del modelo CFD fue
contrastada con los experimentos de Tsalov (2017) prediciendo con bastante
precisión las curvas de caudal vs caída de presión no superando el 15% admisible
para problemas prácticos de la ingeniería. Además, el modelo CFD es capaz de
representar con suficiente aproximación los valores teóricos de Taco (2018) y
experimental de Tsalov (2017) correspondiente al coeficiente de caudal cuando las
aberturas de válvula alcanzan 70% de su valor máximo. Además, se analizó el
comportamiento fluidodinámico de las válvulas bajo ambos escenarios de
operación pudiendo identificarse los mecanismos que gobiernan la formación de la
turbulencia y su disipación de manera a incrementar el entendimiento acerca del
funcionamiento de tales dispositivos. En síntesis, el presente trabajo de
investigación permitió comprender el comportamiento hidráulico de la válvula de
cono fijo, obteniendo información relevante sobre los coeficientes de descarga en
válvulas disipadoras y los parámetros de operación que influyen en su rendimiento.
Estos resultados son fundamentales pues abre nuevas formas de análisis para el
diseño y optimización de este tipo de dispositivos utilizados en la ingeniería
hidráulica | es_PE |
dc.description.abstract | Fixed cone valves, also known as Howell-Bunger valves, are devices used to
safely reduce flow energy in medium to high head dams. These valves direct the
outlet flow into a conical hollow jet, which requires a large area for energy
dissipation. Flow control is carried out through mechanical or hydraulic regulation
systems, and its operation requires minimal energy consumption. The purpose of
this research work was to analyze the hydraulic behavior of Howell-Bunger valve
prototypes, analyzing the different positions of the cylindrical sliding sleeve under
operating conditions of constant flow and hydraulic jump. For both operating
conditions analyzed, ANSYS-CFX was used as a numerical simulation software
package based on the Computational Fluid Dynamics (CFD) for the construction
of the simulation model. For validation, the results of the CFD model were
compared with the experiments of Tsalov (2017), predicting with sufficient
precision the flow rate vs. pressure drop curves, not exceeding the 15%
admissible for practical engineering problems. Furthermore, the CFD model is
capable of representing with sufficient approximation the theoretical values of
Taco (2018) and the experimental values of Tsalov (2017) corresponding to the
flow coefficient when the valve openings reach 70% of their maximum value. In
addition, the fluid-dynamic behavior of the valves was analyzed under both
operating scenarios, allowing the mechanisms that govern the formation of
turbulence and its dissipation to be identified in order to increase understanding
about the operation of such devices. In summary, the present research work
allowed us to understand the hydraulic behavior of the fixed cone valve, obtaining
relevant information about the discharge coefficients in dissipative valves and the
operating parameters that influence their performance. These results are
fundamental as they open new forms of analysis for the design and optimization
of this type of devices used in hydraulic engineering. | es_PE |
dc.description.uri | Tesis | es_PE |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Privada Antenor Orrego | es_PE |
dc.relation.ispartofseries | T_CIVIL_2657 | |
dc.rights | info:eu-repo/semantics/closedAccess | es_PE |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | es_PE |
dc.subject | Dinámica de los Fluidos Computacional | es_PE |
dc.subject | Coeficiente de Descarga | es_PE |
dc.title | Estudio del comportamiento hidráulico de la válvula Howell-Bunger mediante simulación aplicando el programa ANSYS CFX | es_PE |
dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
thesis.degree.grantor | Universidad Privada Antenor Orrego. Facultad de Ingenieria | es_PE |
thesis.degree.name | Ingeniero Civil | es_PE |
thesis.degree.discipline | Ingenieria Civil | es_PE |
dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#2.01.00 | es_PE |
renati.advisor.orcid | https://orcid.org/0000-0003-0505-3163 | es_PE |
renati.author.dni | 47134165 | |
renati.advisor.dni | 18181220 | |
renati.type | https://purl.org/pe-repo/renati/type#tesis | es_PE |
renati.level | https://purl.org/pe-repo/renati/level#tituloProfesional | es_PE |
renati.discipline | 732016 | es_PE |
renati.juror | Cabanillas Quiroz, Guillermo Juan | |
renati.juror | Salazar Perales, Álvaro Fernando | |
renati.juror | Farfán Córdova, Marlon Gastón | |
dc.publisher.country | PE | es_PE |