Análisis comparativo de un concreto tradicional y un concreto utilizando residuos de conchas de abanico para obtener una resistencia 175 kg/cm2
dc.contributor.advisor | Ramal Montejo, Rodolfo Enrique | |
dc.contributor.author | Abanto León, Luis Renato de Jesús | |
dc.contributor.author | García Peña, Mahytel Olexa | |
dc.creator | Abanto León, Luis Renato de Jesús | |
dc.date.accessioned | 2024-12-10T20:34:54Z | |
dc.date.available | 2024-12-10T20:34:54Z | |
dc.date.issued | 2024 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12759/52291 | |
dc.description.abstract | En el presente proyecto de investigación denominado Análisis comparativo de un concreto tradicional y un concreto utilizando residuos de conchas de abanico para obtener una resistencia 175 kg/cm2. Nuestra investigación desea incrementar nuevos materiales que sustituyan en parte los elementos convencionales de la preparación del concreto, así mismo minimizar el impacto ambiental del mismo modo tener un gasto menor al comprobarlo con un concreto tradicional. Por lo cual se pretende darle un nuevo uso al residuo de las conchas de abanico RCA, a través del concreto. Esta tesis tiene como propósito fundamental realizar un diseño de mezcla elaborando así un análisis comparativo para conocer la resistencia de un concreto tradicional y un concreto sustituido por conchas de abanico en porcentajes de 2%, 5% 8% para un concreto f´ c=175kg/cm2 con cemento Portland (Tipo MS), agregado grueso de la Cantera Sojo y agregado fino de la Cantera Cerro Mocho, los cuales se le realizaron ensayos como contenido de humedad, análisis granulométrico, peso específico, peso unitario y al concreto Asentamiento (Slump), se elaboró 36 probetas cilíndricas para la rotura de resistencia a la compresión a los 7,14 y 28 días. Como resultado de los ensayos realizados para obtener una resistencia a la compresión de un concreto 175kg/cm2 se obtuvo que el concreto con adición de RCA de 2% se tiene como resistencia promedio de 186.31kg/cm2, con 5% una resistencia promedio de 192.53kg/cm2 y con 8% una resistencia promedio de 197.90kg/cm2 y del concreto tradicional (muestra patrón) una resistencia promedio a la compresión de 180.10kg/cm2, cumpliendo con la resistencia e inclusive mayor ala requerida | es_PE |
dc.description.abstract | In the present research project called Comparative analysis of a traditional concrete and a concrete using fan shell waste to obtain a resistance of 175 kg/cm2. Our research wants to increase new materials that partly replace the conventional elements of the preparation of concrete, as well as minimize the environmental impact and have a lower cost when compared to traditional concrete. Therefore, it is intended to give a new use to the waste of the RCA fan shells, through concrete. The main purpose of this thesis is to carry out a mix design, thus elaborating a comparative analysis to know the resistance of a traditional concrete and a concrete substituted by fan shells in percentages of 2%, 5% and 8% for a concrete f' c=175kg/cm2 with Portland cement (MS type), coarse aggregate from the Sojo Quarry and fine aggregate from the Cerro Mocho Quarry, which were tested for moisture content, granulometric analysis, specific weight, unit weight and concrete slump, temperature, and 36 cylindrical specimens were prepared for compressive strength at 7, 14 and 28 days. As a result of the tests carried out to obtain a compressive strength of 175kg/cm2 concrete, it was obtained that the concrete with 2% RCA addition has an average strength of 186.31kg/cm2, with 5% an average strength of 192.53kg/cm2 and with 8% an average strength of 197.90kg/cm2 and of the traditional concrete (standard sample) an average compressive strength of 180.10kg/cm2, complying with the required strength and even higher than the required one. | es_PE |
dc.description.uri | Tesis | es_PE |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Privada Antenor Orrego | es_PE |
dc.relation.ispartofseries | T_CIVILP_095 | |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | es_PE |
dc.subject | Residuos de Conchas de Abanico | es_PE |
dc.subject | Agregado Grueso | es_PE |
dc.title | Análisis comparativo de un concreto tradicional y un concreto utilizando residuos de conchas de abanico para obtener una resistencia 175 kg/cm2 | es_PE |
dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
thesis.degree.grantor | Universidad Privada Antenor Orrego. Facultad de Ingenieria | es_PE |
thesis.degree.name | Ingeniero Civil | es_PE |
thesis.degree.discipline | Ingenieria Civil | es_PE |
dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#2.01.00 | es_PE |
renati.advisor.orcid | https://orcid.org/0000-0001-9023-6567 | es_PE |
renati.author.dni | 77684737 | |
renati.author.dni | 70334572 | |
renati.advisor.dni | 40025063 | |
renati.type | https://purl.org/pe-repo/renati/type#tesis | es_PE |
renati.level | https://purl.org/pe-repo/renati/level#tituloProfesional | es_PE |
renati.discipline | 732016 | es_PE |
renati.juror | Príncipe Reyes, Roger Alberto | |
renati.juror | Novoa Castillo, Oscar Walther | |
renati.juror | Rivera Lindo, Dalia Paola | |
dc.publisher.country | PE | es_PE |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(es)
-
Ingeniería Civil [1302]