Actualización de densidad del concreto correlacionando tamaño máximo nominal y aire incorporado para determinar su rendimiento en la ciudad de Trujillo
dc.contributor.advisor | Ochoa Zevallos, Rolando | |
dc.contributor.author | Asto Azabache, Alvaro Ayrton | |
dc.contributor.author | Bázan Rios, Yadira del Pilar | |
dc.creator | Asto Azabache, Alvaro Ayrton | |
dc.date.accessioned | 2019-10-21T17:18:24Z | |
dc.date.available | 2019-10-21T17:18:24Z | |
dc.date.issued | 2019 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12759/5550 | |
dc.description.abstract | En la presente investigación se actualizó la tabla de la primera estimación de la densidad del concreto fresco correlacionándolo con su tamaño máximo nominal y aire incluido, con la utilización del método ACI del diseño de mezclas. La finalidad de actualizar dicha tabla es determinar el rendimiento de los agregados que se utilizan en el distrito de Trujillo. Para poder cumplir este principal objetivo se utilizó el agregado fino y grueso extraídos de dos canteras del distrito de Huanchaco y del distrito de El Milagro, además se utilizó cemento tipo MS (Pacasmayo Fortimax) por lo que es frecuentemente empleado en el distrito de Trujillo, y finalmente efectuándose los ensayos de laboratorio de los agregados regidos por las normas técnicas peruanas y que son requeridos para esta investigación. Con los datos obtenidos del laboratorio, se procedió al diseño de mezclas del concreto empleando el método que propone el comité ACI 211.1, proporcionándonos resultados en las estimaciones del concreto de acuerdo al tamaño máximo nominal, logrando así actualizar la tabla de la primera estimación de densidad del concreto fresco. Finalmente, concluimos que el concreto fresco de peso normal con agregados extraídos de la cantera del distrito de Huanchaco y del distrito de El Milagro, que se obtiene un concreto con 5% de menor densidad y un 2% mayor densidad respectivamente con respecto a la primera estimación de la densidad de la tabla propuesto por el comité ACI 211.1. | es_PE |
dc.description.abstract | In this investigation, we could update the table: First Estimate of Weight of Fesh Concrete, correlating with its nominal maximum size and air-included, using of the ACI method of mixing design. The purpose of updating this table is to determine the performance of the aggregates used in Trujillo district. In order to fulfill this main objective, the fine and coarse aggregate extracted from two quarries in Huanchaco district and El Milagro district were useful, as well as cement type MS (Pacasmayo Fortimax), so it is frequently used in Trujillo district, and finally carrying out the laboratory tests of the aggregates governed by the Peruvian technical standards and which are required for this investigation. With the data obtained from the laboratory, the concrete mixtures were designed using the method proposed by the ACI 211.1 committee, providing results in the estimates of the concrete according to the maximum nominal size, thus updating the table of the first density estimate of fresh concrete. Finally, we conclude that normal heavyweight of fresh concrete with aggregates extracted from the quarry of Huanchaco district and El Milagro district, which obtains a concrete with 5% lower density and 2% higher density respectively with respect to the first estimate of the density of the table proposed by the ACI 211.1 committee. | en_US |
dc.description.uri | Tesis | es_PE |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Privada Antenor Orrego | es_PE |
dc.relation.ispartofseries | T_ING.CIVIL_1770 | |
dc.rights | info:eu-repo/semantics/closedAccess | es_PE |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | es_PE |
dc.source | Universidad Privada Antenor Orrego | es_PE |
dc.source | Repositorio Institucional - UPAO | es_PE |
dc.subject | Concreto | es_PE |
dc.subject | Rendimiento | es_PE |
dc.title | Actualización de densidad del concreto correlacionando tamaño máximo nominal y aire incorporado para determinar su rendimiento en la ciudad de Trujillo | es_PE |
dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
thesis.degree.level | Título Profesional | es_PE |
thesis.degree.grantor | Universidad Privada Antenor Orrego. Facultad de Ingeniería | es_PE |
thesis.degree.name | Ingeniero Civil | es_PE |
thesis.degree.discipline | Ingeniería Civil | es_PE |
dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#2.01.00 | |
renati.type | https://purl.org/pe-repo/renati/type#tesis | |
renati.level | https://purl.org/pe-repo/renati/level#tituloProfesional | |
dc.publisher.country | PE | es_PE |