Mostrar el registro sencillo del ítem

dc.contributor.advisorGalicia Guarniz, William Conrad
dc.contributor.authorPecho Castillo, Diana Durviss
dc.contributor.authorSibina Mego, Carlos Alfredo
dc.creatorPecho Castillo, Diana Durviss
dc.date.accessioned2020-09-14T21:34:26Z
dc.date.available2020-09-14T21:34:26Z
dc.date.issued2020
dc.identifier.urihttps://hdl.handle.net/20.500.12759/6551
dc.description.abstractLas edificaciones esenciales, los hospitales y colegios, son estructuras que deben diseñarse con mayor rigurosidad que las edificaciones comunes. En los últimos años el Análisis Dinámico Incremental (IDA) viene siendo desarrollado con mayor presencia en nuestro país, generando incluso modificaciones en la normativa sísmica peruana de edificación. En el presente trabajo se desarrollará el Análisis Dinámico Incremental del Hospital Virgen de la Puerta ubicado en la ciudad de Trujillo, una moderna edificación de gran importancia en el norte del país y diseñado con una norma ya no vigente. Este estudio lo que busca es determinar el Desempeño Sísmico de la edificación frente al análisis en mención. Para desarrollar este análisis se tuvo que hacer en primer lugar una recopilación de la información de la edificación (planos, esp. Técnicas, memoria descriptiva, etc.) para después realizar el modelamiento estructural en el programa de diseño estructural 3D ETABS. También se seleccionaron 07 pares de registros sísmicos (aceleraciones) los cuales serán utilizados como componentes IDA para su posterior análisis en el programa ETABS. Luego de tener definido la estructura y sus componentes, se procederá a la ejecución del programa, donde obtendremos los siguientes resultados: Desplazamientos Inelásticos de Entrepiso, Derivas Máximas, Índices de Daño y ductilidad de los elementos, Curvas de Capacidad, Curvas IDA, Rigidez de la Edificación y Factor de Reducción Sísmica. Las Curvas IDA son gráficas que relacionan las Derivas Máximas y los Incrementos de aceleración, con estos diagramas podemos definir el Nivel de Desempeño y el estado de Daño de la estructura. Se llegó a determinar que la edificación presenta un nivel de desempeño de “Seguridad de Vida” y un estado de daño “Moderado”.es_PE
dc.description.abstractEssential buildings, hospitals and schools, are structures that must be designed more rigorously than ordinary buildings. In recent years, the Incremental Dynamic Analysis (IDA) has been developed with a greater presence in our country, even generating modifications in the Peruvian seismic building regulations. In this project work, the Incremental Dynamic Analysis of the Virgen de la Puerta Hospital located in the city of Trujillo, a modern building of great importance in the north of the country and designed with a standard no longer in force, will be developed. This study seeks to determine the Seismic Performance of the building through the mentioned analysis. To carry out this analysis, a compilation of the building information (plans, technical specs, descriptive memory, etc.) had to be carried out. Afterwards, a structural modeling was performed in the 3D structural design program ETABS. Seven pairs of seismic records (accelerations) were also selected, which will be used as IDA components for subsequent analysis in the ETABS program. After having defined the structure and its components, the program will be executed, where we will obtain the following results: Inelastic Displacements of Mezzanine, Maximum Drifts, Damage and ductility indexes of the elements, Capacity Curves, IDA Curves, Rigidity of the Building and Seismic Reduction Factor. The IDA Curves are graphs that relate the Maximum Drifts and the Acceleration Increments, with these diagrams we can define the Performance Level and the state of Damage of the structure. It was determined that the building has a ““Life Safety““ performance level and a Moderate““ damage statusen_US
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada Antenor Orregoes_PE
dc.relation.ispartofseriesT_ING.CIVIL_1848
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.sourceUniversidad Privada Antenor Orregoes_PE
dc.sourceRepositorio institucional - UPAOes_PE
dc.subjectSísmicoes_PE
dc.subjectHospitales_PE
dc.titleDeterminación del desempeño sísmico del hospital virgen de la puerta del distrito de la esperanza al aplicar el análisis dinámico incrementales_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.grantorUniversidad Privada Antenor Orrego. Facultad de Ingenieríaes_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.disciplineIngeniería Civiles_PE