Mostrar el registro sencillo del ítem

dc.contributor.advisorGalicia Guarniz, William Conrad
dc.contributor.authorRafael La torre, Ceci Yecelin
dc.contributor.authorValverde Gómez, Pedro Grabiel
dc.creatorRafael La torre, Ceci Yecelin
dc.date.accessioned2020-11-19T11:57:28Z
dc.date.available2020-11-19T11:57:28Z
dc.date.issued2020
dc.identifier.urihttps://hdl.handle.net/20.500.12759/6798
dc.description.abstractEn la actualidad se observa viviendas en el Perú con construcciones informales en sus azoteas con la ejecución de parapetos y alfeizares ya sea de material noble o Drywall. La metodología de construcción en viviendas a nivel mundial es diversa, siendo algunos de ellos contaminantes para el medio ambiente, construcciones a largos plazos y a veces riesgosas en su tiempo de ejecución. En la construcción de parapetos y alfeizares en azoteas se ejecutan muros exteriores con el sistema Drywall con el criterio de aligerar la sobrecarga que se le da a la vivienda dado también que nos brinda una rápida y fácil ejecución en obra, consecuentemente esto nos conlleva a su investigación. Por ello se requiere obtener información de su comportamiento estructural ante una carga perpendicular a su plano y ver los riesgos del mal uso que los maestros de obra le pueden dar a este tipo de material por falta de conocimiento del Manual Técnico SuperBoard, ya que se nos informó y observo que no siguen los requerimientos constructivos que nos brinda el manual técnico. Para nuestro estudio se ejecutaron 12 prototipos de alféizares de Drywall: 4 prototipos con placa de Drywall de 8mm, 4 prototipos con placa de Drywall de 12mm y 4 según recomendaciones de los tesistas con ayuda y criterio de nuestro asesor. Los prototipos fueron sometidos a una carga perpendicular a su plano con un ensayo monotónico, lo que nos lleva a concluir y obtener la información de su comportamiento. Nuestros resultados obtenidos en laboratorio nos muestran el comportamiento de nuestros muros ante cargas perpendiculares a su plano de nuestros alféizares de Drywall según la RNE E.070 se calcula nuestros esfuerzos admisibles en tracción por flexión (dt), donde para muros no portantes (alfeizares y parapetos) este será mayor igual a 1.50 Kg/cm2 , teniendo muros con placas de 8mm con el criterio del maestro de obra se obtuvo 0.72 Kg/cm2 , para muros con placas de 12 mm se obtuvo 1.73 Kg/cm2 y para nuestra propuesta de diseño con placas de 8mm + refuerzo se obtuvo 1.82 Kg/cm2 . Concluyendo que se debe cumplir las especificaciones indicadas en el manual técnico SuperBoard ya que nuestros prototipos #1 no cumplen con lo requerido en la RNE E.070, lo cual se podrá observar con más detalle en los cálculos de gabinetees_PE
dc.description.abstractCurrently, houses in Peru are observed with informal constructions on their roofs with the execution of parapets and sills, whether of noble material or Drywall. The methodology of construction in homes worldwide is diverse, some of them being polluting for the environment, long-term construction and sometimes risky in its execution time. In the construction of parapets and sills on roofs, external walls are executed with the Drywall system with the criterion of lightening the overload that is given to the house since it also gives us a quick and easy execution on site, consequently this leads to its investigation. For this reason, it is required to obtain information on its structural behavior in the face of a load perpendicular to its plane and to see the risks of misuse that construction masters can give to this type of material due to lack of knowledge of the SuperBoard Technical Manual, since we are informed and I observe that they do not follow the constructive requirements that the technical manual provides us. For our study, 12 prototypes of Drywall sills were executed: 4 prototypes with 8mm Drywall plate, 4 prototypes with 12mm Drywall plate and 4 according to the thesis recommendations with the help and judgment of our advisor. The prototypes were subjected to a load perpendicular to their plane with a monotonic test, which leads us to conclude and obtain information on their behavior. Our results obtained in the laboratory show us the behavior of our walls before loads perpendicular to their plane of our Drywall windowsills according to RNE E.070, our admissible stresses in flexural traction (dt) are calculated, where for non-bearing walls (sills and parapets) this will not be greater than 1.50 Kg / cm2, having walls with 8mm plates with the criterion of the master builder 0.72 Kg / cm2 was obtained, for walls with 12mm plates 1.73 Kg / cm2 was obtained and for our proposal of design with 8mm plates + reinforcement, 1.82 Kg / cm2 was obtained. Concluding that the specifications indicated in the SuperBoard technical manual must be met since our # 1 prototypes do not meet the requirements of RNE E.070, which can be observed in more detail in the cabinet calculations.en_US
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada Antenor Orregoes_PE
dc.relation.ispartofseriesT_ING.CIVIL_1869
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/es_PE
dc.sourceUniversidad Privada Antenor Orregoes_PE
dc.sourceRepositorio Institucional - UPAOes_PE
dc.subjectDrywalles_PE
dc.subjectCargases_PE
dc.titleComportamiento de alféizares de drywall reforzados sometido a cargas perpendiculares a su planoes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.grantorUniversidad Privada Antenor Orrego. Facultad de Ingenieríaes_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.disciplineIngeniería Civiles_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.00es_PE
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.discipline732016es_PE
dc.publisher.countryPEes_PE


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(es)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess