dc.description.abstractEl actual informe correspondiente al trabajo de investigación, denominado: “ANÁLISIS NO LINEAL ESTÁTICO EN MUROS DE ALBAÑILERÍA CONFINADA PARA PABELLÓN DE INFRAESTRUCTURA DE I.E.40092 JOSÉ D. ZUZUNAGA OBANDO – UCHUMAYO - AREQUIPA”, se concentró en la aplicación de un método de análisis no-lineal para determinar la respuesta estructural del pabellón en mención. El colegio I.E. 40092 José Domingo Zuzunaga Obando consta de seis pabellones, de los cuales el Bloque 1 fue construido en el año 2016 y corresponden al modelo arquitectónico tipo Sistémico INFES 780 nuevo. El sistema en la dirección X-X es de pórticos, resistido únicamente por columnas de sección TEE y vigas, y un sistema de albañilería confinada para la dirección Y-Y, como se indica en la descripción de la arquitectura. Anteriormente, se han utilizado diferentes y distintos métodos de análisis lineal para evaluar diferentes tipos de estructuras existentes, y se ha determinado que la mayoría de las estructuras de armazón de hormigón y, en algunos casos, la mampostería de carga sufrirá daños considerables en casos severos de terremotos. Para realizar un correcto análisis no lineal es necesario ingresar al diseño elástico y lineal del edificio, debido a que se desarrolló utilizando el programa de cómputo ETABS V.19, en concordancia con las normas sismorresistente E-030 y Albañilería E-070, de nuestro Reglamento Nacional de Edificaciones. Teniendo en cuenta los lineamientos del cálculo y método Pushover se calculó el análisis no lineal estático en ambos ejes principales del Bloque 1, para ello se ha empleado modelos inelásticos que distribuyen la plasticidad a lo largo de los elementos estructurales analizados, debido a que estos son modelos más sofisticados que proporcionan mayor información de cada fibra del elemento estructural, para realizar el modelo no lineal se utilizó como herramienta el software ix Etabs19 teniendo en cuenta que para el eje X-X elementos tipo “frame” de igual manera para los muros de albañilería confinada del eje Y-Y los elementos tipo “Links”, donde para efectos de cálculo realizaremos las verificaciones con los niveles de sismo dados por el ATC – 40 conjuntamente con los niveles de desempeños, dados por La Propuesta del Comité VISION 2000 (SEAOC, 1995), teniendo en consideración que para el Sismo Raro se considera como Sismo de diseño y con respecto al sismo muy raro será equivalente con el sismo máximo. Obteniendo finalmente el desempeño sísmico de un sismo de diseño y uno máximo para la dirección de análisis “Y” según el comité VISION 2000 (SEAOC, 1995). Además de los desplazamientos espectrales del pabellón de infraestructura de la I.E.40092 José D. Zuzunaga Obando, en la dirección de análisis “Y” y así recomendar consideraciones a tener en cuenta después de aplicado el Análisis No Lineal Estáticoes_PE
dc.description.abstractThe current report corresponding to the research work, called: ““ANÁLISIS NO LINEAL ESTÁTICO EN MUROS DE ALBAÑILERÍA CONFINADA PARA PABELLÓN DE INFRAESTRUCTURA DE I.E.40092 JOSÉ D. ZUZUNAGA OBANDO – UCHUMAYO - AREQUIPA““, focused on the application of an analysis method not - linear to determine the structural response of the pavilion in question. The I.E. 40092 José Domingo Zuzunaga Obando consists of six pavilions, of which Block 1 was built in 2016 and correspond to the new systemic INFES 780 architectural model. The system in the X-X direction is of frames, resisted only by TEE section columns and beams, and a confined masonry system for the Y-Y direction, as indicated in the architecture description. Previously, different and different linear analysis methods have been used to evaluate different types of existing structures, and it has been determined that most concrete frame structures and in some cases load-bearing masonry will suffer considerable damage in severe cases. of earthquakes. To perform a correct non-linear analysis, it is necessary to enter the elastic and linear design of the building, since it was developed using the ETABS V.19 computer program, in accordance with the E-030 and E-070 seismic resistant standards, of our National Building Regulations. Taking into account the guidelines of the calculation and Pushover method, the static non-linear analysis was calculated in both main axes of Block 1, for this inelastic models have been used that distribute the plasticity along the analyzed structural elements, because these are More sophisticated models that provide more information on each fiber of the structural element. To make the non-linear model, the Etabs19 software was used as a tool, taking into account that for the XX axis “frame” elements in the same way for the confined masonry walls of the Y axis and “Links” xi type elements, where for calculation purposes we will carry out the verifications with the earthquake levels given by ATC - 40 together with the performance levels, given by the VISION 2000 Committee Proposal (SEAOC, 1995), having in consideration that for the Rare Earthquake it is considered as a design earthquake and with respect to the very rare earthquake it will be equivalent to the earthquake or maximum. Finally obtaining the seismic performance of a design earthquake and a maximum one for the analysis direction ““Y““ according to the VISION 2000 committee (SEAOC, 1995). In addition to the spectral displacements of the infrastructure pavilion of the I.E. 40092 José D. Zuzunaga Obando, in the direction of analysis ““Y““ and thus recommend considerations to take into account after applying the Static Nonlinear Analysisen_US
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada Antenor Orregoes_PE
dc.relation.ispartofseriesT_CIVIL_2032
dc.rightsinfo:eu-repo/semantics/closedAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/es_PE
dc.sourceUniversidad Privada Antenor Orregoes_PE
dc.sourceRepositorio Institucional - UPAOes_PE
dc.subjectNo Lineales_PE
dc.subjectPabellónes_PE
dc.titleAnálisis no lineal estático en muros de albañilería confinada para pabellón de infraestructura de I.E.40092 José D. Zuzunaga Obando – Uchumayo - Arequipaes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.grantorUniversidad Privada Antenor Orrego. Facultad de Ingenieríaes_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.disciplineIngeniería Civiles_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.00es_PE
renati.advisor.orcidhttps://orcid.org/0000-0003-4506-9290es_PE
renati.author.dni75208612
renati.author.dni73899636
renati.advisor.dni41420875
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.discipline732016es_PE
renati.jurorAlanoca Quenta, Ángel
renati.jurorGarcía Rivera, Juan
renati.jurorMedina Carbajal, Lucio
dc.publisher.countryPEes_PE


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/closedAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/closedAccess