dc.contributor.advisor | Salazar Cruzado, Orlando Rodolfo | |
dc.contributor.author | Salazar Rengifo, Orlando Benjamin | |
dc.creator | Salazar Rengifo, Orlando Benjamin | |
dc.date.accessioned | 2018-04-12T21:00:42Z | |
dc.date.available | 2018-04-12T21:00:42Z | |
dc.date.issued | 2018 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12759/3975 | |
dc.description.abstract | Objetivo: Determinar si existe asociación entre el circular de cordón y la asfixia
neonatal en recién nacidos por parto vaginal en el Hospital Belén de Trujillo.
Material y Método: Se llevó a cabo un estudio de tipo o bs e r v a ci on a l , t r a n s v e r s al ,
r e t r os p e ct i v o , an al í t i c o con diseño de cohorte. La población de estudio estuvo conformada por
8007 recién nacidos por parto vaginal, quienes fueron divididos en 2 grupos: con circular de cordón
(n= 267) y sin circular de cordón (n= 7967).
Resultado: La incidencia de asfixia neonatal en recién nacidos con circular de cordón fue 3.30%.
La asfixia neonatal fue significativamente mayor en el grupo de recién nacidos con circular de
cordón (RR: 2.6 IC 95%: 1.83 – 7.17; p<0.01). Las características demográficas maternas y
obstétricas fueron similares en recién nacidos con y sin circular de cordón (p>0.05). Se encontraron
diferencias significativas en la reanimación respiratoria (p<0.01), hospitalización (p<0.01), Apgar al
minuto (p<0.01) y Apgar a los 5 minutos (p<0.05) entre los recién nacidos con y sin circular de
cordón.
Conclusiones: El circular de cordón es un factor de riesgo para asfixia neonatal en el parto vaginal.
Existe una asociación de la reanimación respiratoria, hospitalización, Apgar al minuto y a los 5
minutos con la presencia de circular de cordón; al compararlos con el grupo de sin circular de
cordón. | es_PE |
dc.description.abstract | Objetive: Determine if there is an association between nuchal cord and asphyxia neonatorum in
newborns by vaginal delivery at Hospital Belén de Trujillo.
Material and Method: An observational, cross-sectional, retrospective, analytical study with
cohort design was carried out. The study population was formed by 8007 newborns in vaginal
delivery, who were divided into 2 groups: with nuchal cord (n = 267) and without nuchal cord (n =
7967).
Results: The incidence of asphyxia neonatorum in newborns with nuchal cord was
3.30%. Asphyxia neonatorum was significantly higher in nuchal cord group (RR:
2.6 95% CI: 1.83 - 7.17, p <0.01). Demographic and obstetric features were similar
in neonates with and without nuchal cord (p> 0.05). There were significant
differences in respiratory resuscitation (p <0.01), hospitalization (p <0.01), Apgar at
the minute (p <0.01) and Apgar at 5 minutes (p <0.05) among newborns with and
without cord.
Conclusions: Nuchal cord is a risk factor for asphyxia neonatorum in vaginal
delivery. There is an association of respiratory resuscitation, hospitalization, Apgar
to the minute and to the 5 minutes with the presence of nuchal cord; when compared
to the group without nuchal cord. | en_US |
dc.description.uri | Tesis | es_PE |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Privada Antenor Orrego - UPAO | es_PE |
dc.relation.ispartofseries | T_MED.HUMA_2357 | |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.source | Universidad Privada Antenor Orrego | es_PE |
dc.source | Repositorio Institucional - UPAO | es_PE |
dc.subject | Circular de cordón | es_PE |
dc.subject | Asfixia neonatal | es_PE |
dc.title | Circular de cordón asociado a asfixia neonatal en el parto vaginal | es_PE |
dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
thesis.degree.level | Título Profesional | es_PE |
thesis.degree.grantor | Universidad Privada Antenor Orrego. Facultad de Medicina Humana | es_PE |
thesis.degree.name | Médico Cirujano | es_PE |
thesis.degree.discipline | Medicina Humana | es_PE |