Show full item recordAbstract
El proyecto desarrollado como tema de tesis, comprende el diseño estructural de un edificio destinado al uso de hotel de 6 pisos el edificio se encuentra ubicado entre dos edificaciones a mitad de la cuadra, nuestro terreno cuenta con un frente de 15.15 m, con sus lados derecho e izquierdo cuentan con 20.35 m y 20.39 m respectivamente. El semisótano consta de una zona de estacionamiento, cuarto de bomba, cisterna, servicios higiénicos de uso público y escalera de emergencia. El terreno está ubicado en el distrito de Nuevo Chimbote, el cual se encuentra sobre un terreno de perfil tipo S3 (Con una carga admisible de 1.429 Kg/cm2). El área por cada nivel es de aproximadamente de 290m2 haciendo un total de 1740 m2 de área construida.
La estructura del edificio consiste en elementos de concreto armado. Se hicieron calzaduras para el semisótano en ambas direcciones. Dada la ubicación del terreno se tiene asimetría en planta, la cual se ha disminuido con la inclusión de muros o columnas alargadas convenientemente ubicadas y sin afectar la arquitectura.
En cuanto al armado de las losas se utilizaron losas aligeradas de una dirección con un peralte de 25 y 17cm (ver plano de detalles de los techos).
En el semisótano se encuentra ubicado la cisterna, el cuarto de bombas y el estacionamiento. En la azotea está ubicado el tanque elevado para el almacenamiento de agua.
Como tema adicional, se llevó a cabo el metrado del concreto y del acero de refuerzo de todos los elementos estructurales diseñados, con la finalidad de verificar si su diseño ha sido eficiente o pocó en exceso o defecto, según los índices obtenidos por metro cuadrado construido sean mayores o menores a los establecidos de acuerdo a la práctica del diseño estructural.
Para el cálculo de la estructuras de cimentación del edificio del proyecto, se ha considerado que la resistencia o capacidad portante del suelo, tiene un valor de 1.429 Kg/cm2, siendo la profundidad de cimentación de 3.05m. The project developed as a thesis subject , comprising the structural design of a building
for the use of the 6-storey hotel building is located halfway between two buildings on the
block , our land has a frontage of 15.15 m, with sides right and left have 20.35 m 20.39 m
respectively. The basement consists of a parking area , pump room , cistern, toilet facilities
for public use and emergency stairs . The land is located in the district of Nuevo Chimbote,
which is located on a plot of S3 type profile ( With a load capacity of 1,429 kg/cm2 ) . The
goal for each level is approximately 290m2 totaling 1740 m2 of built area.
The structure consists of reinforced concrete elements . Calzaduras for semi basement were
made in both directions . Given the location of the ground floor has asymmetry , which
decreased with the inclusion of walls or columns conveniently located lengthened without
affecting the architecture.
As the armed slabs lightened slabs used an address with a camber of 25 and 17cm (see map
details on the roof ) .
In the semi basement is located the tank, pump room and parking . The rooftop overhead
tank for water storage is located .
As an additional issue , held the subrack of concrete and reinforcing steel for all structural
elements designed with the purpose of verifying that its design has been efficient or too
much or too little , as the indices obtained per square meter built be higher or lower
according to the established practice of structural design.
For the calculation of the foundation structures of the building project has been considered
that the strength or bearing capacity, has a value of 1.429 Kg/cm2, being the foundation
depth of 3.05m.
Also, the seismic analysis of the structure according to the parameters established by the
earthquake resistant design standard E-030.El seismic analysis will be conducted to obtain
the response of the structure under dynamic stress, yielding:
a) the main periods of vibration.
b) The base shear and lateral movements to which it is subject and finally
c) Efforts horizontal earthquake forces generated by structural elements (beams, columns
and plates)
For the design of beams, columns and plates that make up the structure of the building,
seismic forces obtained by the dynamic seismic analysis were used.