dc.description.abstractComparar la exactitud diagnóstica de fracturas dentales mediante dos sistemas de radiografía digital: sensor digital (SD) y placa de fósforo (PFF). MATERIALES Y METODOS: Este es un estudio observacional, transversal, descriptivo, prolectivo, en el que 144 cirujanos dentistas observaron 12 imágenes radiográficas a través de dos sistemas de radiografía digital: el sensor digital (SD) woodpeker I sensor H2 y placa de fosforo fotoestimulable (PFF) de la marca alemana Durr® Dental. Se utilizaron 6 piezas dentales premolares para cada sistema, dividiéndose en dos sanas, dos con fracturas verticales y dos horizontales; para simular las fracturas se utilizó un alicate cortador, se determinó la exactitud de las propiedades diagnósticas mediante las respuestas de los observadores. RESULTADOS: Al comparar la exactitud diagnóstica, se obtuvo un 67.36% para el SD y un 55.67% para la PFF. La sensibilidad fue de 52.60% para el SD mientras que para la PFF fue de 35.42%, la especificidad fue del 96% en ambos sistemas. En cuanto la exactitud diagnóstica en las fracturas horizontales, el SD alcanzó un 97.92% y para la PFF un 82.64%; sin embargo, en las fracturas verticales fue menor 51.46% para el SD y 48.86 para la PFF. La concordancia Kappa fue moderada para fracturas ausentes (0.544) y verticales (0.509), y casi perfecta para fracturas horizontales (0.927). CONCLUSIONES: Existen diferencias en la exactitud diagnóstica en las fracturas dentales, donde el sensor digital demostró ser más exacto en comparación con la placa de fósforoes_PE
dc.description.abstractCompare the diagnostic accuracy of dental fractures using two digital radiography systems: digital sensor (SD) and phosphor plate (PFF)) MATERIALS AND METHODS: This is an observational, cross-sectional, descriptive, prolective study, in which 144 dental surgeons observed 12 radiographic images through two digital radiography systems: the woodpeker digital sensor (SD) I H2 sensor and photostimulable phosphor plate . (PFF) from the German brand Durr® Dental. 6 premolar teeth were used for each system, dividing them into two healthy ones, two with vertical fractures and two horizontal ones; To simulate fractures, cutting pliers are used; the accuracy of the diagnostic properties will be determined through the observers' responses. RESULTS: When comparing the diagnostic accuracy, 67.36% was obtained for the SD and 55.67% for the PFF. The sensitivity was 52.60% for the SD while for the PFF it was 35.42%, the specificity was 96% in both systems. Regarding the diagnostic accuracy in horizontal fractures, the SD reached 97.92% and for the PFF 82.64%; However, in vertical fractures it was lower 51.46% for the SD and 48.86 for the PFF. Kappa agreement was moderate for absent (0.544) and vertical fractures (0.509), and almost perfect for horizontal fractures (0.927). CONCLUSIONS: There are differences in diagnostic accuracy in dental fractures, where the digital sensor proved to be more accurate compared to the phosphorus platees_PE
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada Antenor Orregoes_PE
dc.relation.ispartofseriesT_ESTO_1184
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/es_PE
dc.subjectRadiografía Digital Dentales_PE
dc.subjectFracturas de los Dienteses_PE
dc.titleExactitud diagnóstica de fracturas dentales mediante dos sistemas de radiografía digitales_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.grantorUniversidad Privada Antenor Orrego. Facultad de Medicina Humanaes_PE
thesis.degree.nameCirujana Dentistaes_PE
thesis.degree.disciplineEstomatologíaes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.02.14es_PE
renati.advisor.orcidhttps://orcid.org/0000-0003-2379-1346es_PE
renati.author.dni71050643
renati.advisor.dni40062518
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.discipline911016es_PE
renati.jurorTresierra Puga, Miguel Felix
renati.jurorMego Zarate, Nelson Javier
renati.jurorPortales Carbonel, Carol Ximena
dc.publisher.countryPEes_PE


Files in this item

Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess