Show simple item record

dc.contributor.advisorDurand Orellana, Rocío del Pilar
dc.contributor.authorPastor Huamaní, Luis Manuel
dc.contributor.authorReyes Narro, Diego Alonso
dc.creatorPastor Huamaní, Luis Manuel
dc.date.accessioned2022-07-25T23:45:37Z
dc.date.available2022-07-25T23:45:37Z
dc.date.issued2022
dc.identifier.urihttps://hdl.handle.net/20.500.12759/9216
dc.description.abstractEn esta investigación se realizó el estudio de diferentes mezclas de un concreto permeable con la finalidad de aplicarse en un pavimento rígido en la ciudad de Trujillo, Perú. Para lograr esto, se realizó los ensayos de laboratorio respectivos a los materiales requeridos. Desde el material extraído (agregados) de la cantera “Quebrada el León” hasta los ensayos de laboratorio propios del concreto permeable. Una vez realizadas las pruebas respectivas a los agregados, se realizó el diseño de mezcla tanto del concreto patrón (concreto convencional con una resistencia de diseño f’c = 280 kg/cm2 ), como del concreto permeable, utilizando la metodología del ACI 211.1 y del ACI 522R-10 respectivamente. Una vez realizado el diseño de mezcla, se sometió el concreto patrón y las diferentes mezclas de concreto permeable a los diferentes ensayos, sabiendo que un pavimento rígido trabaja a flexión, se sometieron a las pruebas de resistencia a la flexión (con carga a los tercios). Para finalizar esta investigación, se dan a conocer y se discuten los resultados obtenidos de tal manera de señalar si este tipo de concreto es apto y conveniente para poder aplicarlo en un pavimento rígido. Realizada esta investigación concluimos que, al analizar los resultados, se aprecia que el porcentaje de vacíos influye en la resistencia a la compresión, resistencia a la flexión y permeabilidad de un concreto permeable. Mientras más porcentaje de vacíos tenga este concreto, menor será su resistencia, tanto a la compresión como a la flexión y mayor será su índice de permeabilidad. Teniendo como referencia investigaciones anteriores en los antecedentes, se nos dio a conocer que el concreto permeable posee una baja resistencia a la compresión y flexión, debido a esto decidimos utilizar el aditivo SIKACEM plastificante con finalidad de alcanzar la resistencia deseada. Una vez realizado los ensayos observamos que la mezcla de concreto permeable 2, alcanzo y supero la resistencia mínima establecida en la norma (ce.010 Pavimentos Urbanos).es_PE
dc.description.abstractIn this research, the study of different mixtures of a permeable concrete was carried out with the purpose of being applied in a rigid pavement in the city of Trujillo, Peru. To achieve this, the respective laboratory tests were carried out on the required materials. From the material extracted (aggregates) from the ““Quebrada el León““ quarry to the laboratory tests of the permeable concrete. Once the respective tests were performed on the aggregates, the mix design of both the standard concrete (conventional concrete with a design strength f'c = 280 kg/cm2) and the pervious concrete was carried out, using the methodology of ACI 211.1 and ACI 522R-10, respectively. Once the mix design was carried out, the standard concrete and the different pervious concrete mixes were subjected to the different tests, knowing that a rigid pavement works in flexure, they were subjected to flexural strength tests (with load to the thirds). To conclude this research, the results obtained are presented and discussed in order to indicate if this type of concrete is suitable and convenient to be applied in a rigid pavement. After this research, we conclude that, when analyzing the results, it can be seen that the percentage of voids influences the compressive strength, flexural strength and permeability of a permeable concrete. The higher the percentage of voids in this concrete, the lower its compressive and flexural strength and the higher its permeability index. Having as reference previous research in the background, we learned that permeable concrete has a low compressive and flexural strength, so we decided to use the plasticizing SIKACEM admixture in order to achieve the desired strength. Once the tests were carried out, we observed that the mixture of pervious concrete 2, reached and surpassed the minimum resistance established in the norm (ce.010 Urban Pavements).en_US
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada Antenor Orregoes_PE
dc.relation.ispartofseriesT_CIVIL_2089
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/es_PE
dc.sourceUniversidad Privada Antenor Orregoes_PE
dc.sourceRepositorio Institucional - UPAOes_PE
dc.subjectConcretoes_PE
dc.subjectPermeablees_PE
dc.titlePropiedades físicas de un concreto permeable aplicado a un pavimento rígido en Trujillo, Perúes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.grantorUniversidad Privada Antenor Orrego. Facultad de Ingenieríaes_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.disciplineIngeniería Civiles_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.00es_PE
renati.advisor.orcidhttps://orcid.org/0000-0002-6592-6520es_PE
renati.author.dni70364261
renati.author.dni72809252
renati.advisor.dni18186640
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.discipline732016es_PE
renati.jurorVargas López, Segundo
renati.jurorLopez Otiniano, Stewart
renati.jurorMedia Carbajal, Lucio
dc.publisher.countryPEes_PE


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess