Mostrar el registro sencillo del ítem

dc.contributor.advisorMedina Carbajal, Lucio Sigifredo
dc.contributor.authorLuna Usquiano, Dayane Gladys
dc.contributor.authorRubio Calderón, Miguel Ángel
dc.creatorLuna Usquiano, Dayane Gladys
dc.date.accessioned2022-08-15T12:51:06Z
dc.date.available2022-08-15T12:51:06Z
dc.date.issued2022
dc.identifier.urihttps://hdl.handle.net/20.500.12759/9316
dc.description.abstractEn el presente trabajo se analiza las propiedades mecánicas existentes de un adoquín convencional y se realiza la comparación de estas propiedades entre un adoquín que fue modificado con conchas de abanico. Se elaboraron adoquines sustituyendo diferentes porcentajes (8%, 10% y/o 15%) de agregado por conchas de abanico, de este modo buscamos que las propiedades mecánicas de este adoquín modificado sean superiores y destaquen más por su tiempo de vida útil que un adoquín convencional. La metodología que se realizó, para la siguiente investigación es del tipo experimental, puesto que mediante ensayos se evaluó los resultados obtenidos, para esto primero denominamos a nuestros grupos de estudio en: Grupo de control y Grupo experimental, en el cual se usó como agregado a cierto porcentaje de conchas de abanico con relación al procedimiento de diseño del adoquín modificado y con el diseño del adoquín convencional, debido a que la concha de abanico posee un alto contenido de calcio, carbono y oxigeno CaCO3 siendo estos uno de los componentes principales del cemento, por lo tanto al usarlo como agregado se espera obtener buenos resultados. Se fabricó adoquines modificados cuyas dimensiones a escala 1/3 son de 6.67 centímetros para el largo, 3.33 centímetros para el ancho y 2.67 centímetros para su altura, cuyo curado se realizó en los 7 días iniciales para posteriormente realizar los correspondientes ensayos que solicita la norma E.070 (2020) que consiste en ensayos de alabeo, variación dimensional, absorción y resistencia a la compresión. Los ensayos que se realizó a los adoquines con una sustitución de 15% de concha de abanico se obtuvo una resistencia a la compresión la cual supero la carga mínima que está establecido en la norma. En cuanto al resto de ensayos que son de absorción, alabeo y variación dimensional se obtuvo resultados que cumplen con lo establecido con la norma. Por último, al grupo experimental o adoquines modificados con conchas de abanico se les hizo una comparación con el grupo de control o adoquín convencional tipo C, obteniendo resultados, con relación a la mínima resistencia que está establecida en la norma.es_PE
dc.description.abstractIn the present work, the comparison of the mechanical properties between a conventional paver and a modified paver with fan shells is analyzed. Paving stones were made by substituting different percentages (8%, 10% and / or 15%) of aggregate for fan shells, in this way we seek that the mechanical properties of this modified paving stone are superior and stand out more for its useful life than a conventional paving stone. The methodology that was carried out for the following research is of the experimental type, since the results obtained were evaluated through tests, for this we first called our study groups in: Control group and Experimental group, in which it was used as an aggregate a certain percentage of fan shells in relation to the modified paving stone design procedure and with the conventional paver design, because the fan shell has a high content of calcium, carbon and oxygen CaCO3, these being one of the main components of the cement, therefore when using it as an aggregate it is expected to obtain good results. Modified paving stones were manufactured whose 1/3 scale dimensions are 6.67 cm long, 3.33 cm wide and 2.67 cm high, whose curing was carried out in the initial 7 days to later carry out the corresponding tests requested by the E.070 standard (2020) which consists of warping, dimensional variation, absorption and compressive strength tests. The tests carried out on the pavers with a 15% substitution of fan shell obtained a resistance to compression which exceeded the minimum load established in the standard. As for the rest of the tests that are of absorption, warping and dimensional variation, results were obtained that comply with the provisions of the standard. Finally, a comparison was made to the experimental group or modified pavers with fan shells with the control group or conventional type C pavers, obtaining results in relation to the minimum resistance that is established in the standarden_US
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada Antenor Orregoes_PE
dc.relation.ispartofseriesT_CIVIL_2095
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/es_PE
dc.sourceUniversidad Privada Antenor Orregoes_PE
dc.sourceRepositorio Institucional - UPAOes_PE
dc.subjectAdoquínes_PE
dc.subjectConchases_PE
dc.titleAnálisis comparativo de las propiedades mecánicas entre un adoquín convencional y un adoquín modificado con conchas de abanico a escalaes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.grantorUniversidad Privada Antenor Orrego. Facultad de Ingenieríaes_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.disciplineIngeniería Civiles_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.00es_PE
renati.advisor.orcidhttps://orcid.org/0000-0001-5207-4421es_PE
renati.author.dni76331481
renati.author.dni70479892
renati.advisor.dni40534510
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.discipline732016es_PE
renati.jurorVargas Lopez, Alfredo
renati.jurorSalazar Perales, Alvaro
renati.jurorVertiz Malabrigo, Manuel
dc.publisher.countryPEes_PE


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(es)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess